Portable system for imaging of /spl alpha/, /spl beta/ and X-ray sources with silicon pixel detectors and Medipix 1 read out

A portable system has been developed for the control and the readout of a 64/spl times/64 pixel silicon hybrid detector (1.1/spl times/1.1 cm/sup 2/ active area), bump-bonded to the Medipix1 readout chip. This system was originally designed for biomedial imaging applications and is based on standard commercial digital I/O boards and a compact dedicated interface (p-MUROS), connected to the portable PC. The Medipix1 chip is hosted in a 257 Pin Grid Array chip carrier directly placed on the p-MUROS board. This board is the simplified version of the MUROS1 readout board already developed in the framework of the Medipix collaboration. User-friendly software system (Medisoft 3.3) has been written to provide control of the system and image acquisition, display and processing. This complete hardware/software imaging system has been used with laboratory /spl alpha/, /spl beta/ and /spl gamma/ sources for test purposes and represents the portable version of a desktop imaging system developed for /spl beta/-autoradiography. The system description and complete imaging tests are presented. Additional applications include the monitoring of the flux and the energy spectrum of X-rays tubes.

[1]  George W. Fraser,et al.  An MCP-based system for beta autoradiography , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[2]  E. Bertolucci,et al.  Real time /spl beta/-imaging with silicon hybrid pixel detectors: investigations into amino acids uptake and genetics , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).

[3]  G. Meddeler,et al.  A Readout Chip for a 64 x 64 Pixel Matrix with 15-bit Single Photon Counting* , 1997 .

[4]  R. Dinapoli,et al.  Medipix2: A 64-k pixel readout chip with 55-/spl mu/m square elements working in single photon counting mode , 2001 .

[5]  Giovanni Mettivier,et al.  Preliminary test of an imaging probe for nuclear medicine using hybrid pixel detectors , 2002 .

[6]  Piernicola Oliva,et al.  Imaging spectroscopic performances for a Si based detection system , 2000, 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149).

[7]  E. Bertolucci,et al.  A new read-out system for an imaging pixel detector , 2000, 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149).

[8]  Giovanni Mettivier,et al.  Evaluation of a photon-counting hybrid pixel detector array with a synchrotron X-ray source , 2002 .

[9]  Giovanni Mettivier,et al.  Quantitative dynamic imaging of biological processes with solid state radiation detectors , 1999 .

[10]  K Wells,et al.  The performance of a CCD digital autoradiography imaging system. , 2000, Physics in medicine and biology.

[11]  M. Campbell,et al.  Readout for a 64/spl times/64 pixel matrix with 15-bit single photon counting , 1997, 1997 IEEE Nuclear Science Symposium Conference Record.