A digital filtration technique for scatter-glare correction based on thickness estimation

In order to quantitate anatomical and physiological parameters such as vessel dimensions and volumetric blood flow, it is necessary to make corrections for scatter and veiling glare, which are the major sources of nonlinearities in videodensitometric digital subtraction angiography (DSA). A convolution filtering technique has been investigated to estimate scatter-glare distribution in DSA images without the need to sample the scatter-glare intensity for each patient. This technique utilizes exposure parameters and image gray levels to assign equivalent Lucite thickness for every pixel in the image. The thickness information is then used to estimate scatter-glare intensity on a pixel-by-pixel basis. To test its ability to estimate scatter-glare intensity, the correction technique was applied to images of a Lucite step phantom, anthropomorphic chest phantom, head phantom, and animal models at different thicknesses, projections, and beam energies. The root-mean-square (rms) percentage error of these estimates was obtained by comparison with direct scatter-glare measurements made behind a lead strip. The average rms percentage errors in the scatter-glare estimate for the 25 phantom studies and the 17 animal studies were 6.44% and 7.96%, respectively. These results indicate that the scatter-glare intensity can be estimated with adequate accuracy for a wide range of thicknesses, projections, and beam energies using exposure parameters and gray level information.

[1]  M L Giger,et al.  Digital radiographic imaging system with multiple-slit scanning x-ray beam: preliminary report. , 1986, Radiology.

[2]  M Honda,et al.  Method for estimating the intensity of scattered radiation using a scatter generation model. , 1991, Medical physics.

[3]  D B Plewes,et al.  A scanning system for chest radiography with regional exposure control: practical implementation. , 1983, Medical physics.

[4]  C A Mistretta,et al.  Quantification techniques for dual-energy cardiac imaging. , 1989, Medical physics.

[5]  T Ema,et al.  A technique of scatter-glare correction using a digital filtration. , 1993, Medical physics.

[6]  C A Mistretta,et al.  Scatter-glare corrections in quantitative dual-energy fluoroscopy. , 1988, Medical physics.

[7]  J A Seibert,et al.  Monte Carlo simulation of the scattered radiation distribution in diagnostic radiology. , 1988, Medical physics.

[8]  J A Sorenson,et al.  Scatter rejection by air gaps: an empirical model. , 1985, Medical physics.

[9]  I A Brezovich,et al.  The design and performance of a scanning multiple slit assembly. , 1979, Medical physics.

[10]  Quantitative dual-energy coronary arteriography. , 1990, Investigative radiology.

[11]  Orhan Nalcioglu,et al.  Quantitative Aspects of Image Intensifier- Television-Based Digital X-Ray Imaging , 1986 .

[12]  S Molloi,et al.  Absolute volumetric blood flow measurements using dual-energy digital subtraction angiography. , 1993, Medical physics.

[13]  A. Macovski,et al.  Dual-energy x-ray projection imaging: two sampling schemes for the correction of scattered radiation. , 1988, Medical physics.

[14]  D B Plewes,et al.  Quantitative digital subtraction angiography: two scanning techniques for correction of scattered radiation and veiling glare. Work in progress. , 1985, Radiology.

[15]  J A Seibert,et al.  X-ray scatter removal by deconvolution. , 1988, Medical physics.

[16]  C A Mistretta,et al.  Scatter-glare correction using a convolution algorithm with variable weighting. , 1987, Medical physics.

[17]  S. Molloi,et al.  Absolute cross-sectional area measurements in quantitative coronary arteriography by dual-energy DSA. , 1991, Investigative radiology.

[18]  C A Mistretta,et al.  A technique of scatter and glare correction for videodensitometric studies in digital subtraction videoangiography. , 1982, Radiology.

[19]  R. Kruger,et al.  Scatter estimation for a digital radiographic system using convolution filtering. , 1987, Medical physics.