An analysis of the factors affecting hybrid ground-source heat pump installation potential in North America

Growing demands for space heating and cooling make ground-source heat pump (GSHP) systems a viable renewable alternative. The economic outlook of potential installations can be addressed by hybridizing GSHP systems with an auxiliary system. To better understand optimization factors in sizing hybrid GSHP systems, a series of sensitivity analyses have been performed. Using a rigorous mathematical, computational approach to size hybrid GSHP systems recently published in Alavy et al. (2013), the use of sensitivity analyses has allowed for a better determination of the impact that variations in input parameters have on the performance of GSHPs. A total of five analyses were performed to determine the effects that operating costs, inflation, geographical location within North America, and a seasonality control strategy have on sizing hybrid GSHP systems. The effects inflation of natural gas and/or electricity prices have depends on a building’s energy demands. An inflation (deflation) in electricity rates makes hybrid GSHP systems for very cooling (heating) dominant buildings more economical compared to conventional systems. Installations of smaller GSHP systems are more economical when considering time-of-use electricity rates compared to fixed electricity rates, for buildings with long operating hours during off-peak periods. However, downsizing the ground loop system causes an increase in annual operating costs which result in longer payback periods. Similarly, if a building is situated in a location with warmer weather where ground temperatures are thus higher, an optimally designed system will tend to have a shorter ground loop length. By meeting less of the building’s peak energy demands (hybrid shave factor) substantially reduces the initial costs of the ground-loop installation.

[1]  José M. Corberán,et al.  Experimental and modeling analysis of a ground source heat pump system , 2013 .

[2]  Wei Song,et al.  Energy saving and economic analyses of design heating load ratio of ground source heat pump with gas boiler as auxiliary heat source , 2011, 2011 International Conference on Electric Technology and Civil Engineering (ICETCE).

[3]  Tao Yang,et al.  Experimental study of a solar-assisted ground-coupled heat pump system with solar seasonal thermal storage in severe cold areas , 2010 .

[4]  C. D. Rakopoulos,et al.  Cooling dominated Hybrid Ground Source Heat Pump System application , 2012 .

[5]  Zoi Sagia,et al.  New Control Strategy for a Hybrid Ground Source Heat Pump System coupled to a Closed Circuit Cooling Tower , 2012 .

[6]  Wei Shen,et al.  A techno-economic comparison of a direct expansion ground-source and a secondary loop ground-coupled heat pump system for cooling in a residential building , 2012 .

[7]  Jae Hyung Roh,et al.  Economic analysis of heating and cooling systems from the various perspectives: Application to EHP and GHP in Korea , 2012 .

[8]  Wenming Yang,et al.  Advances in heat pump systems: A review , 2010 .

[9]  Lingen Chen,et al.  Solar and ground source heat-pump system , 2004 .

[10]  Chao Chen,et al.  Underground water-source loop heat-pump air-conditioning system applied in a residential building in Beijing , 2005 .

[11]  Pradeep K. Sahoo,et al.  Study of technical, economical and environmental viability of ground source heat pump system for Himalayan cities of India , 2015 .

[12]  Hiep V. Nguyen,et al.  A methodology and computerized approach for optimizing hybrid ground source heat pump system design , 2013 .

[13]  Philipp Blum,et al.  Techno-economic and spatial analysis of vertical ground source heat pump systems in Germany , 2011 .

[14]  Nicholas Jenkins,et al.  Power requirements of ground source heat pumps in a residential area , 2013 .

[15]  Yan Shang,et al.  Intermittent experimental study of a vertical ground source heat pump system , 2014 .

[16]  Emanuele Borgonovo,et al.  Model emulation and moment-independent sensitivity analysis: An application to environmental modelling , 2012, Environ. Model. Softw..

[17]  Alan S. Fung,et al.  Performance prediction of a hybrid solar ground-source heat pump system , 2012 .

[18]  Wenjie Gang,et al.  Predictive ANN models of ground heat exchanger for the control of hybrid ground source heat pump systems , 2013 .

[19]  Valerio Lo Brano,et al.  Life cycle assessment of a solar thermal collector: sensitivity analysis, energy and environmental balances , 2005 .

[20]  Alan S. Fung,et al.  Feasibility of combined solar thermal and ground source heat pump systems in cold climate, Canada , 2013 .

[21]  David Jenkins,et al.  Modelling the carbon-saving performance of domestic ground-source heat pumps , 2009 .

[22]  Marc A. Rosen,et al.  Geothermal heat pump systems: Status review and comparison with other heating options , 2013 .

[23]  Hongxing Yang,et al.  Feasibility study on novel hybrid ground coupled heat pump system with nocturnal cooling radiator for cooling load dominated buildings , 2011 .

[24]  Hongxing Yang,et al.  Vertical-borehole ground-coupled heat pumps: A review of models and systems , 2010 .

[25]  B. Perers,et al.  Optimization of systems with the combination of ground-source heat pump and solar collectors in dwellings , 2010 .

[26]  Jinggang Wang,et al.  Study on hybrid ground-coupled heat pump system for air-conditioning in hot-weather areas like Hong Kong , 2010 .

[27]  José M. Corberán,et al.  In situ optimization methodology for the water circulation pumps frequency of ground source heat pump systems , 2014 .

[28]  Jeffrey D. Spitler,et al.  Status and development of hybrid energy systems from hybrid ground source heat pump in China and other countries , 2014 .

[29]  Evgueniy Entchev,et al.  Simulation of hybrid renewable microgeneration systems in load sharing applications , 2013 .

[30]  O. Comakli,et al.  Energy analysis of a solar-ground source heat pump system with vertical closed-loop for heating appl , 2011 .

[31]  Paola Annoni,et al.  Sixth International Conference on Sensitivity Analysis of Model Output How to avoid a perfunctory sensitivity analysis , 2010 .

[32]  Wenxing Shi,et al.  A potential solution for thermal imbalance of ground source heat pump systems in cold regions: Ground source absorption heat pump , 2013 .

[33]  Yong Chan Kim,et al.  The cooling seasonal performance factor of a hybrid ground-source heat pump with parallel and serial configurations , 2013 .

[34]  Joachim Rohn,et al.  Experimental investigation of a borehole field by enhanced geothermal response test and numerical analysis of performance of the borehole heat exchangers , 2015 .

[35]  Abdeen Mustafa Omer,et al.  Ground-source heat pumps systems and applications , 2008 .

[36]  Omer Ozyurt,et al.  Experimental study of vertical ground-source heat pump performance evaluation for cold climate in Turkey , 2011 .