Revisiting cooling energy requirements of residential buildings in Portugal in light of climate change

Abstract Since climate data for building energy simulation have recently been refreshed with 1971–2000 observational data and theoretically influenced by a conservative approach of climate change, benchmarks for cooling energy requirements for residential buildings are discussed for a set of 30 regions in Portugal, mainland and islands, as a contribution to the next revision of Portuguese building thermal code (DL 118/2013). The main conclusion is that gain utilization factor correlates with average external air temperature for summer season by a logarithmic function. The benchmark for gain utilization factor plays an important role in defining cooling energy requirements. A set of recommendations are suggested: (i) using the gain utilization factor as an index to evaluate the overheating risk, thus, for values above a defined threshold cooling energy needs could be neglected for primary energy demand quantification; this measure may encourage designers to integrate passive cooling systems; (ii) defining a national roadmap based on technological advances of shading solutions for benchmark parameterization of the west equivalent collecting area by unit of floor area starting from 0.065.

[1]  M. Hamdy,et al.  A multi-stage optimization method for cost-optimal and nearly-zero-energy building solutions in line with the EPBD-recast 2010 , 2013 .

[2]  S. Alvarez,et al.  Tightening the energy consumptions of buildings depending on their typology and on Climate Severity Indexes , 2013 .

[3]  Marta J.N. Oliveira Panão,et al.  Passive Cooling Load Ratio method , 2013 .

[4]  M. Macias,et al.  Low cost passive cooling system for social housing in dry hot climate , 2009 .

[5]  F. Nicol,et al.  Derivation of the adaptive equations for thermal comfort in free-running buildings in European standard EN15251 , 2010 .

[6]  Servando Álvarez Domínguez,et al.  A new methodology towards determining building performance under modified outdoor conditions , 2006 .

[7]  Enrico Fabrizio,et al.  Building energy performance assessment through simplified models: Application of the ISO 13790 quasi-steady state method , 2007 .

[8]  J. Kurnitski,et al.  Performance of EN ISO 13790 utilisation factor heat demand calculation method in a cold climate , 2007 .

[9]  S. M. Shiva Nagendra,et al.  Passive alternatives to mechanical air conditioning of building: A review , 2013 .

[10]  Vítor Leal,et al.  A methodology for economic efficient design of Net Zero Energy Buildings , 2012 .

[11]  R Aguiar,et al.  Climate change impacts on the thermal performance of Portuguese buildings. Results of the SIAM study , 2002 .

[12]  Moncef Krarti,et al.  Design optimization of energy efficient residential buildings in Tunisia , 2012 .

[13]  Enrico Fabrizio,et al.  A simplified calculation method of the annual energy use for space heating and cooling: assessment of the dynamic parameters for the Italian building stock and climate , 2006 .

[14]  Meral Ozel,et al.  Determination of optimum insulation thickness based on cooling transmission load for building walls in a hot climate , 2013 .

[15]  Susana Camelo,et al.  Assessment of the Portuguese building thermal code: Newly revised requirements for cooling energy ne , 2011 .

[16]  Targo Kalamees,et al.  Cost optimal and nearly zero (nZEB) energy performance calculations for residential buildings with R , 2011 .

[17]  Helder Gonçalves,et al.  Climatologia e anos meteorológicos de referência para o Sistema Nacional de Certificação de Edifícios (versão 2013) , 2013 .

[18]  Baruch Givoni,et al.  Performance and applicability of passive and low-energy cooling systems , 1991 .

[19]  K. Calvin,et al.  The RCP greenhouse gas concentrations and their extensions from 1765 to 2300 , 2011 .