Flow and dispersion in coupled outdoor and indoor environments: Issue of Reynolds number independence

Abstract The Reynolds number ( R e ) independence criteria for flow and dispersion around purely outdoor environments has been examined in many previous studies, but little attention has been paid to the coupled outdoor and indoor environments. This study investigated the R e independence criteria of flow and dispersion in coupled outdoor and indoor environments using Computational Fluid Dynamics (CFD) with Large Eddy Simulation (LES) model. Two geometrical arrangements were considered, namely an isolated multi-story building, and an array of multi-story buildings. Four parameters including the non-dimensional air velocity, pollutant concentration, ventilation rate, and re-entry ratio were used to assess the R e independence criteria. The tracer gas decay method was used to predict the ventilation rate and to quantify the re-entry ratio for each room. Using the quantitative indicator, the deviation rate (DR), of the non-dimensional velocity below 5%, two sets of critical values were proposed: R e H based on the building height equal to 4.8 × 10 4 for the outdoor environment, and R e W based on the opening height equal to 1.4 × 10 4 for the indoor environment. The concentration field was more difficult to meet the R e -independent requirement. Using the DR of the non-dimensional concentration below 5%, the critical values were R e H = 7.9 × 10 4 and R e W = 3.0 × 10 4 . If the DR was enlarged to 10%, the R e H and R e W criteria for the concentration field were the same as the velocity fields. For the non-dimensional ventilation rate and re-entry ratio, the critical value for the R e independence was R e W  =  1.4 × 10 4 for both the isolated buildings and the building arrays.

[1]  Louis Lazure,et al.  Contamination of Fresh Air Intakes Due to Downwash from a Rooftop Structure , 2009, Journal of the Air & Waste Management Association.

[2]  R. Ooka,et al.  Studies on critical Reynolds number indices for wind-tunnel experiments on flow within urban areas , 2003 .

[3]  Cheuk Ming Mak,et al.  Large eddy simulation of wind‐induced interunit dispersion around multistory buildings , 2015, Indoor air.

[4]  Cm M. Mak,et al.  Potential use of reduced-scale models in CFD simulations to save numerical resources: Theoretical analysis and case study of flow around an isolated building , 2014 .

[5]  Qingyan Chen,et al.  Ventilation performance prediction for buildings: A method overview and recent applications , 2009 .

[6]  C. Mak,et al.  Evaluation of computational and physical parameters influencing CFD simulations of pollutant dispersion in building arrays , 2018, Building and Environment.

[7]  Bje Bert Blocken,et al.  Full-scale measurements of indoor environmental conditions and natural ventilation in a large semi-enclosed stadium : possibilities and limitations for CFD validation , 2012 .

[8]  Theodore Stathopoulos,et al.  Effects of model scale in estimating pollutant dispersion near buildings , 1995 .

[9]  S-J Cao,et al.  On the construction and use of linear low-dimensional ventilation models. , 2012, Indoor air.

[10]  W. Tao,et al.  Numerical investigations on Re-independence for the turbulent flow and pollutant dispersion under the urban boundary layer with some experimental validations , 2017 .

[11]  J. Smagorinsky,et al.  GENERAL CIRCULATION EXPERIMENTS WITH THE PRIMITIVE EQUATIONS , 1963 .

[12]  Mattheos Santamouris,et al.  On the combination of air velocity and flow measurements in single sided natural ventilation configurations , 1996 .

[13]  Z T Ai,et al.  Numerical investigation of wind-induced airflow and interunit dispersion characteristics in multistory residential buildings. , 2013, Indoor air.

[14]  Cheuk Ming Mak,et al.  Analysis of fluctuating characteristics of wind-induced airflow through a single opening using LES modeling and the tracer gas technique , 2014 .

[15]  Cheuk Ming Mak,et al.  A study of interunit dispersion around multistory buildings with single-sided ventilation under different wind directions , 2014 .

[16]  Bje Bert Blocken,et al.  CFD simulation of cross-ventilation flow for different isolated building configurations: validation with wind tunnel measurements and analysis of physical and numerical diffusion effects , 2012 .

[17]  Zhuangbo Feng,et al.  Study on the impacts of human walking on indoor particles dispersion using momentum theory method , 2017 .

[18]  N. Gao,et al.  Wind tunnel tests of inter-flat pollutant transmission characteristics in a rectangular multi-storey residential building, part B: Effect of source location , 2016, Building and Environment.

[19]  Jon A. Peterka,et al.  Wind Tunnel Investigations of Natural Ventilation , 1984 .

[20]  A. Longhetto,et al.  Laboratory simulation of rotating atmospheric boundary layer flows over obstacles , 1983 .

[21]  Cheuk Ming Mak,et al.  Large-eddy Simulation of flow and dispersion around an isolated building: Analysis of influencing factors , 2015 .

[22]  Bert Blocken,et al.  50 years of Computational Wind Engineering: Past, present and future , 2014 .

[23]  Cheuk Ming Mak,et al.  Modeling of coupled urban wind flow and indoor air flow on a high-density near-wall mesh: Sensitivity analyses and case study for single-sided ventilation , 2014, Environ. Model. Softw..

[24]  Alan Robins,et al.  Effects of Reynolds number on stack plume trajectories simulated with small scale models in a wind tunnel , 2009 .

[25]  D. Lilly,et al.  A proposed modification of the Germano subgrid‐scale closure method , 1992 .

[26]  Refrigerating ASHRAE handbook of fundamentals , 1967 .

[27]  Xiaoping Liu,et al.  Numerical simulation of inter-flat air cross-contamination under the condition of single-sided natural ventilation , 2008 .

[28]  J. Niu,et al.  Investigation of indoor air pollutant dispersion and cross-contamination around a typical high-rise residential building : wind tunnel tests , 2010 .

[29]  Di Mu,et al.  Wind tunnel tests of inter-flat pollutant transmission characteristics in a rectangular multi-storey residential building, part A: Effect of wind direction , 2016, Building and Environment.

[30]  Kenny C. S Kwok,et al.  CFD simulation of the effect of an upstream building on the inter-unit dispersion in a multi-story building in two wind directions , 2016, Journal of Wind Engineering and Industrial Aerodynamics.

[31]  W. Tao,et al.  Investigation of Re-independence of turbulent flow and pollutant dispersion in urban street canyon using numerical wind tunnel (NWT) models , 2014 .

[32]  P. Heiselberg,et al.  The airborne transmission of infection between flats in high-rise residential buildings: Tracer gas simulation , 2007, Building and Environment.

[33]  J Niu,et al.  On-site quantification of re-entry ratio of ventilation exhausts in multi-family residential buildings and implications. , 2007, Indoor air.

[34]  Tze Wai Wong,et al.  Evidence of airborne transmission of the severe acute respiratory syndrome virus. , 2004, The New England journal of medicine.