Flow and dispersion in coupled outdoor and indoor environments: Issue of Reynolds number independence
暂无分享,去创建一个
Cheuk Ming Mak | Zhengtao Ai | Yuwei Dai | C. Mak | Z. Ai | Y. Dai | Zhengtao Ai
[1] Louis Lazure,et al. Contamination of Fresh Air Intakes Due to Downwash from a Rooftop Structure , 2009, Journal of the Air & Waste Management Association.
[2] R. Ooka,et al. Studies on critical Reynolds number indices for wind-tunnel experiments on flow within urban areas , 2003 .
[3] Cheuk Ming Mak,et al. Large eddy simulation of wind‐induced interunit dispersion around multistory buildings , 2015, Indoor air.
[4] Cm M. Mak,et al. Potential use of reduced-scale models in CFD simulations to save numerical resources: Theoretical analysis and case study of flow around an isolated building , 2014 .
[5] Qingyan Chen,et al. Ventilation performance prediction for buildings: A method overview and recent applications , 2009 .
[6] C. Mak,et al. Evaluation of computational and physical parameters influencing CFD simulations of pollutant dispersion in building arrays , 2018, Building and Environment.
[7] Bje Bert Blocken,et al. Full-scale measurements of indoor environmental conditions and natural ventilation in a large semi-enclosed stadium : possibilities and limitations for CFD validation , 2012 .
[8] Theodore Stathopoulos,et al. Effects of model scale in estimating pollutant dispersion near buildings , 1995 .
[9] S-J Cao,et al. On the construction and use of linear low-dimensional ventilation models. , 2012, Indoor air.
[10] W. Tao,et al. Numerical investigations on Re-independence for the turbulent flow and pollutant dispersion under the urban boundary layer with some experimental validations , 2017 .
[11] J. Smagorinsky,et al. GENERAL CIRCULATION EXPERIMENTS WITH THE PRIMITIVE EQUATIONS , 1963 .
[12] Mattheos Santamouris,et al. On the combination of air velocity and flow measurements in single sided natural ventilation configurations , 1996 .
[13] Z T Ai,et al. Numerical investigation of wind-induced airflow and interunit dispersion characteristics in multistory residential buildings. , 2013, Indoor air.
[14] Cheuk Ming Mak,et al. Analysis of fluctuating characteristics of wind-induced airflow through a single opening using LES modeling and the tracer gas technique , 2014 .
[15] Cheuk Ming Mak,et al. A study of interunit dispersion around multistory buildings with single-sided ventilation under different wind directions , 2014 .
[16] Bje Bert Blocken,et al. CFD simulation of cross-ventilation flow for different isolated building configurations: validation with wind tunnel measurements and analysis of physical and numerical diffusion effects , 2012 .
[17] Zhuangbo Feng,et al. Study on the impacts of human walking on indoor particles dispersion using momentum theory method , 2017 .
[18] N. Gao,et al. Wind tunnel tests of inter-flat pollutant transmission characteristics in a rectangular multi-storey residential building, part B: Effect of source location , 2016, Building and Environment.
[19] Jon A. Peterka,et al. Wind Tunnel Investigations of Natural Ventilation , 1984 .
[20] A. Longhetto,et al. Laboratory simulation of rotating atmospheric boundary layer flows over obstacles , 1983 .
[21] Cheuk Ming Mak,et al. Large-eddy Simulation of flow and dispersion around an isolated building: Analysis of influencing factors , 2015 .
[22] Bert Blocken,et al. 50 years of Computational Wind Engineering: Past, present and future , 2014 .
[23] Cheuk Ming Mak,et al. Modeling of coupled urban wind flow and indoor air flow on a high-density near-wall mesh: Sensitivity analyses and case study for single-sided ventilation , 2014, Environ. Model. Softw..
[24] Alan Robins,et al. Effects of Reynolds number on stack plume trajectories simulated with small scale models in a wind tunnel , 2009 .
[25] D. Lilly,et al. A proposed modification of the Germano subgrid‐scale closure method , 1992 .
[26] Refrigerating. ASHRAE handbook of fundamentals , 1967 .
[27] Xiaoping Liu,et al. Numerical simulation of inter-flat air cross-contamination under the condition of single-sided natural ventilation , 2008 .
[28] J. Niu,et al. Investigation of indoor air pollutant dispersion and cross-contamination around a typical high-rise residential building : wind tunnel tests , 2010 .
[29] Di Mu,et al. Wind tunnel tests of inter-flat pollutant transmission characteristics in a rectangular multi-storey residential building, part A: Effect of wind direction , 2016, Building and Environment.
[30] Kenny C. S Kwok,et al. CFD simulation of the effect of an upstream building on the inter-unit dispersion in a multi-story building in two wind directions , 2016, Journal of Wind Engineering and Industrial Aerodynamics.
[31] W. Tao,et al. Investigation of Re-independence of turbulent flow and pollutant dispersion in urban street canyon using numerical wind tunnel (NWT) models , 2014 .
[32] P. Heiselberg,et al. The airborne transmission of infection between flats in high-rise residential buildings: Tracer gas simulation , 2007, Building and Environment.
[33] J Niu,et al. On-site quantification of re-entry ratio of ventilation exhausts in multi-family residential buildings and implications. , 2007, Indoor air.
[34] Tze Wai Wong,et al. Evidence of airborne transmission of the severe acute respiratory syndrome virus. , 2004, The New England journal of medicine.