The power conversion system in the gas turbine modular helium reactor (GT-MHR) power plant is based on a highly recuperated closed Brayton cycle. The major component in the direct cycle system is a helium closed-cycle gas turbine rated at 286 MW(e). The rotating group consists of an intercooled helium turbocompressor coupled to a synchronous generator. The vertical rotating assembly is installed in a steel vessel, together with the other major components (i.e., recuperator, precooler, intercooler, and connecting ducts and support structures). The rotor is supported on an active magnetic bearing system. The turbine operates directly on the reactor helium coolant, and with a temperature of 850{degree}C (1562{degree}F) the plant efficiency is over 47%. This paper addresses the design and development planning of the helium turbomachine, and emphasizes that with the utilization of proven technology, this second generation nuclear power plant could be in service in the first decade of the 21st century.
[1]
Colin F. McDonald,et al.
Turbomachinery Design Considerations for the Nuclear HTGR-GT Power Plant
,
1980
.
[2]
W. Endres.
Large Helium Turbines for Nuclear Power Plants
,
1970
.
[3]
R. L. Casper.
Application of the LM6000 for Power Generation and Cogeneration
,
1993
.
[4]
H. Haselbacher,et al.
Development of helium gas turbine systems in the nuclear field
,
1974
.
[5]
Colin F. McDonald.
Enabling Technologies for Nuclear Gas Turbine (GT-MHR) Power Conversion System
,
1994
.
[6]
Colin F. McDonald,et al.
The key role of heat exchangers in advanced gas-cooled reactor plants
,
1994
.
[7]
C. P. HAIGH.
Gas-Cooled Reactor Technology
,
1964,
Nature.