Parallelization Of The EM Algorithm For 3D PEt Image Reconstruction

The EM algorithm for PET image reconstruction has two major drawbacks that have impeded the routine use of the EM algorithm: the long computation time due to slow convergence and a large memory required for the image, projection, and probability matrix. An attempt is made to solve these two problems by parallelizing the EM algorithm on multiprocessor systems. An efficient data and task partitioning scheme, called partition-by-box, based on the message passing model is proposed. The partition-by-box scheme and its modified version have been implemented on a message passing system, Intel iPSC/2, and a shared memory system, BBN Butterfly GP1000. The implementation results show that, for the partition-by-box scheme, a message passing system of complete binary tree interconnection with fixed connectivity of three at each node can have similar performance to that with the hypercube topology, which has a connectivity of log(2) N for N PEs. It is shown that the EM algorithm can be efficiently parallelized using the (modified) partition-by-box scheme with the message passing model.

[1]  C. J. Thompson,et al.  A Fractional Address Accumulator for Fast Back-Projection , 1981, IEEE Transactions on Nuclear Science.

[2]  Jorge Llacer,et al.  Matrix-Based Image Reconstruction Methods for Tomography , 1985, IEEE Transactions on Nuclear Science.

[3]  K. Lange,et al.  EM reconstruction algorithms for emission and transmission tomography. , 1984, Journal of computer assisted tomography.

[4]  N. Mullani,et al.  A Real-Time Tofpet Slice-Backproject Engine Employing Dual Am29116 Microprocessors , 1985, IEEE Transactions on Nuclear Science.

[5]  Linda Kaufman,et al.  Implementing and Accelerating the EM Algorithm for Positron Emission Tomography , 1987, IEEE Transactions on Medical Imaging.

[6]  L. G. Byars,et al.  Positron emission tomographic images and expectation maximization: a VLSI architecture for multiple iterations per second , 1988 .

[7]  C. M. Chen,et al.  Incremental algorithm-a new fast backprojection scheme for parallel beam geometries. , 1990, IEEE transactions on medical imaging.

[8]  Zang-Hee Cho,et al.  A parallel implementation of 3-D CT image reconstruction on hypercube multiprocessor , 1990 .

[9]  Robert M. Lewitt,et al.  Accelerated Iterative Reconstruction for Positron Emission Tomography Based on the EM Algorithm for Maximum Likelihood Estimation , 1986, IEEE Transactions on Medical Imaging.

[10]  T. M. Peters Algorithms for Fast Back- and Re-Projection in Computed Tomography , 1981 .

[11]  M. Casey,et al.  Design of a super fast three-dimensional projection system for positron emission tomography , 1990 .

[12]  L. Shepp,et al.  Maximum Likelihood Reconstruction for Emission Tomography , 1983, IEEE Transactions on Medical Imaging.

[13]  David A. Chesler,et al.  Three Dimensional Image Reconstruction in the Fourier Domain , 1987, IEEE Transactions on Nuclear Science.