Estimation of kinetic parameters without input functions: analysis of three methods for multichannel blind identification
暂无分享,去创建一个
[1] Richard E. Carson,et al. Absolute cerebral blood flow with /sup 15/O-water and PET: determination without a measured input function , 1994, Proceedings of 1994 IEEE Nuclear Science Symposium - NSS'94.
[2] Yoram Bresler,et al. Exact maximum likelihood parameter estimation of superimposed exponential signals in noise , 1986, IEEE Trans. Acoust. Speech Signal Process..
[3] Wan-Chi Siu,et al. A technique for extracting physiological parameters and the required input function simultaneously from PET image measurements: theory and simulation study , 1997, IEEE Transactions on Information Technology in Biomedicine.
[4] G. Gullberg,et al. Blind estimation of compartmental model parameters. , 1999, Physics in medicine and biology.
[5] D. Feng,et al. Noninvasive Quantification of the Cerebral Metabolic Rate for Glucose Using Positron Emission Tomography, 18F-Fluoro-2-Deoxyglucose, the Patlak Method, and an Image-Derived Input Function , 1998, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.
[6] Richard E. Carson,et al. Chapter 36 - Absolute Cerebral Blood Flow with [ 15 O]Water and PET: Determination Without a Measured Input Function , 1996 .
[7] R. Wilson,et al. Myocardial perfusion reserve: assessment with multisection, quantitative, first-pass MR imaging. , 1997, Radiology.
[8] F Lazeyras,et al. Quantification of myocardial perfusion with FAST sequence and Gd bolus in patients with normal cardiac function , 1999, Journal of magnetic resonance imaging : JMRI.
[9] W J Manning,et al. Studies of Gd‐DTPA relaxivity and proton exchange rates in tissue , 1994, Magnetic resonance in medicine.
[10] J R MacFall,et al. Quantification of myocardial perhsion by MRI after coronary occlusion , 1998, Magnetic resonance in medicine.
[11] R. Coleman,et al. MRI quantitative myocardial perfusion with compartmental analysis: A rest and stress study , 1997, Magnetic resonance in medicine.
[12] L. Tong,et al. Multichannel blind identification: from subspace to maximum likelihood methods , 1998, Proc. IEEE.
[13] David Dagan Feng,et al. Simultaneous estimation of physiological parameters and the input function - in vivo PET data , 2001, IEEE Transactions on Information Technology in Biomedicine.
[14] David Dagan Feng,et al. Non-invasive quantification of physiological processes with dynamic PET using blind deconvolution , 1998, Proceedings of the 1998 IEEE International Conference on Acoustics, Speech and Signal Processing, ICASSP '98 (Cat. No.98CH36181).
[15] H. Oswald,et al. Noninvasive detection of myocardial ischemia from perfusion reserve based on cardiovascular magnetic resonance. , 2000, Circulation.
[16] Chrysostomos L. Nikias,et al. EVAM: an eigenvector-based algorithm for multichannel blind deconvolution of input colored signals , 1995, IEEE Trans. Signal Process..
[17] V. Dhawan,et al. Noninvasive quantitative fluorodeoxyglucose PET studies with an estimated input function derived from a population-based arterial blood curve. , 1993, Radiology.
[18] J. Nocedal,et al. A Limited Memory Algorithm for Bound Constrained Optimization , 1995, SIAM J. Sci. Comput..