A Novel Method for Fault Location of Transmission Lines by Wide-Area Voltage Measurements Considering Measurement Errors

Smart transmission grids are intended to utilize various measurements for enhanced operation. In particular, synchronized phasor measurements have found many applications in this context. This paper presents a linear weighted least-squares (WLS) method for fault location estimation of transmission lines by synchronized voltage measurements. The measurements may be taken from the faulted line terminals or buses far from the faulted line. The circuit equations of the network are used to find the transfer function between the fault location and each voltage measurement. Next, two auxiliary variables are defined to transform the nonlinear fault location estimation problem into a linear WLS problem. A closed-form solution is then obtained for fault location. The use of multiple measurements provides the opportunity of identifying erroneous measurements by a statistical test. The linearity of the problem expedites both estimation and identification procedures. Moreover, the method requires neither to classify the fault type nor to estimate the fault resistance. Furthermore, transmission lines are modeled by distributed parameters so that the method can be applicable to long lines. Electromagnetic transient simulations for 9-bus and 22-bus test systems reveal accurate fault location estimation, regardless of fault type and resistance, as well as successful identification of measurement errors.

[1]  I. Zamora,et al.  Fault location on two-terminal transmission lines based on voltages , 1996 .

[2]  L.C. Zanetta,et al.  Fault location in transmission lines using one-terminal postfault voltage data , 2004, IEEE Transactions on Power Delivery.

[3]  A. G. Expósito,et al.  Power system state estimation : theory and implementation , 2004 .

[4]  J. Izykowski,et al.  A Fault-Location Method for Application With Current Differential Relays of Three-Terminal Lines , 2007, IEEE Transactions on Power Delivery.

[5]  A. Abur,et al.  Optimal Deployment of Wide-Area Synchronized Measurements for Fault-Location Observability , 2013, IEEE Transactions on Power Systems.

[6]  Zhao Yang Dong,et al.  An Adaptive Dynamic Phasor Estimator Considering DC Offset for PMU Applications , 2011, IEEE Transactions on Power Delivery.

[7]  I. Zamora,et al.  A new technique, based on voltages, for fault location on three-terminal transmission lines , 1996 .

[8]  Y. G. Paithankar,et al.  Online digital fault locator for overhead transmission line , 1979 .

[9]  Jianhui Wang,et al.  Smart Transmission Grid: Vision and Framework , 2010, IEEE Transactions on Smart Grid.

[10]  Gevork B. Gharehpetian,et al.  Optimal Integration of Phasor Measurement Units in Power Systems Considering Conventional Measurements , 2013, IEEE Transactions on Smart Grid.

[11]  A. T. Johns,et al.  Accurate fault location technique for power transmission lines , 1990 .

[12]  Bo Wang,et al.  PMU-Based Fault Location Using Voltage Measurements in Large Transmission Networks , 2012, IEEE Transactions on Power Delivery.

[13]  A.A. Girgis,et al.  Fault location on a transmission line using synchronized Voltage measurements , 2004, IEEE Transactions on Power Delivery.

[14]  M. Saha,et al.  An Accurate Fault Locator With Compensation For Apparent Reactance In The Fault Resistance Resulting From Remore-End Infeed , 1985, IEEE Transactions on Power Apparatus and Systems.

[15]  A. Wiszniewski Accurate fault impedance locating algorithm , 1983 .

[16]  Chi-Shan Yu,et al.  A Fault Location Technique for Two-Terminal Multisection Compound Transmission Lines Using Synchronized Phasor Measurements , 2012, IEEE Transactions on Smart Grid.

[17]  T. Takagi,et al.  Development of a New Type Fault Locator Using the One-Terminal Voltage and Current Data , 1982, IEEE Power Engineering Review.

[18]  N. Otsuzuki,et al.  Development of a new fault location system for multi-terminal single transmission lines , 1994, Proceedings of IEEE/PES Transmission and Distribution Conference.

[19]  Tarlochan S. Sidhu,et al.  A Simple Synchrophasor Estimation Algorithm Considering IEEE Standard C37.118.1-2011 and Protection Requirements , 2013, IEEE Transactions on Instrumentation and Measurement.

[20]  A. Abur,et al.  Traveling-Wave-Based Fault-Location Technique for Transmission Grids Via Wide-Area Synchronized Voltage Measurements , 2012, IEEE Transactions on Power Systems.

[21]  G. M. Burt,et al.  P and M Class Phasor Measurement Unit Algorithms Using Adaptive Cascaded Filters , 2013, IEEE Transactions on Power Delivery.

[22]  Ali Mohammad Ranjbar,et al.  Optimal PMU Placement by an Equivalent Linear Formulation for Exhaustive Search , 2012, IEEE Transactions on Smart Grid.

[23]  M. S. Sachdev,et al.  A technique for estimating transmission line fault locations from digital impedance relay measurements , 1988 .

[24]  Yuan Liao Fault Location Utilizing Unsynchronized Voltage Measurements During Fault , 2006 .

[25]  Damir Novosel,et al.  Unsynchronized two-terminal fault location estimation , 1996 .

[26]  Adly A. Girgis,et al.  A new fault location technique for two- and three-terminal lines , 1992 .

[27]  Akhtar Kalam,et al.  A practical approach to accurate fault location on extra high voltage teed feeders , 1993 .

[28]  Majid Sanaye-Pasand,et al.  A Straightforward Method for Wide-Area Fault Location on Transmission Networks , 2015, IEEE Transactions on Power Delivery.

[29]  A. Abur,et al.  Fault Location Using Voltage Measurements , 2001, IEEE Power Engineering Review.

[30]  Yuan Liao,et al.  Double-Circuit Transmission-Line Fault Location With the Availability of Limited Voltage Measurements , 2012, IEEE Transactions on Power Delivery.

[31]  Mladen Kezunovic,et al.  Smart Fault Location for Smart Grids , 2011, IEEE Transactions on Smart Grid.