Analysis of recent pharmaceutical regulatory documents on analytical method validation.

All analysts face the same situations as method validation is the process of proving that an analytical method is acceptable for its intended purpose. In order to resolve this problem, the analyst refers to regulatory or guidance documents, and therefore the validity of the analytical methods is dependent on the guidance, terminology and methodology, proposed in these documents. It is therefore of prime importance to have clear definitions of the different validation criteria used to assess this validity. It is also necessary to have methodologies in accordance with these definitions and consequently to use statistical methods which are relevant with these definitions, the objective of the validation and the objective of the analytical method. The main purpose of this paper is to outline the inconsistencies between some definitions of the criteria and the experimental procedures proposed to evaluate those criteria in recent documents dedicated to the validation of analytical methods in the pharmaceutical field, together with the risks and problems when trying to cope with contradictory, and sometimes scientifically irrelevant, requirements and definitions.

[1]  Jörgen Vessman,et al.  Generating selectivity in analytical chemistry to reach the ultimate -specificity , 1998 .

[2]  A. G. González,et al.  Accuracy profiles from uncertainty measurements. , 2006, Talanta.

[3]  B. A. Persson,et al.  The use of selectivity in analytical chemistry – some considerations , 2001 .

[4]  H. Kaiser,et al.  Zur Definition von Selektivität, Spezifität und Empfindlichkeit von Analysenverfahren , 1972 .

[5]  Andrew Wilkinson Compendium of Chemical Terminology , 1997 .

[6]  Vinod P. Shah,et al.  Validation of Bioanalytical Methods , 1991, Pharmaceutical Research.

[7]  Michael Thompson,et al.  Harmonized guidelines for single-laboratory validation of methods of analysis (IUPAC Technical Report) , 2002 .

[8]  P. Hubert,et al.  Validation of a liquid chromatographic-tandem mass spectrometric method for the determination of loperamide in human plasma. , 2005, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[9]  Avraham Lorber,et al.  Net analyte signal calculation in multivariate calibration , 1997 .

[10]  Joachim Ermer,et al.  Validation in pharmaceutical analysis. Part II: Central importance of precision to establish acceptance criteria and for verifying and improving the quality of analytical data. , 2005, Journal of pharmaceutical and biomedical analysis.

[11]  K. Danzer Selectivity and specificity in analytical chemistry. General considerations and attempt of a definition and quantification , 2001, Fresenius' journal of analytical chemistry.

[12]  Walthère Dewé,et al.  Risk management for analytical methods based on the total error concept: Conciliating the objectives of the pre-study and in-study validation phases , 2007 .

[13]  J. Vessman,et al.  Selectivity or specificity? Validation of analytical methods from the perspective of an analytical chemist in the pharmaceutical industry. , 1996, Journal of pharmaceutical and biomedical analysis.

[14]  Jörgen Vessman Selectivity – the hallmark of an analytical chemist: the current situation in the analytical sciences , 2001 .

[15]  David Hoffman,et al.  TWO-SIDED TOLERANCE INTERVALS FOR BALANCED AND UNBALANCED RANDOM EFFECTS MODELS , 2005, Journal of biopharmaceutical statistics.

[16]  Philippe Hubert,et al.  validation des procédures analytiques quantitatives. Harmonisation des démarches. Session d'étude présentée par les membres de la commission , 2003 .

[17]  Bruno Boulanger,et al.  Optimal designs for inverse prediction in univariate nonlinear calibration models , 2004 .

[18]  J. Vial,et al.  What is the best means of estimating the detection and quantification limits of a chromatographic method? , 2003 .

[19]  Robert W. Mee β-Expectation and β-Content Tolerance Limits for Balanced One-Way ANOVA Random Model@@@b-Expectation and b-Content Tolerance Limits for Balanced One-Way ANOVA Random Model , 1984 .

[20]  Philippe Hubert,et al.  New advances in method validation and measurement uncertainty aimed at improving the quality of chemical data , 2004, Analytical and bioanalytical chemistry.

[21]  Alain Jardy,et al.  Experimental Comparison of the Different Approaches To Estimate LOD and LOQ of an HPLC Method , 1999 .

[22]  Viswanath Devanarayan,et al.  Fit-for-Purpose Method Development and Validation for Successful Biomarker Measurement , 2006, Pharmaceutical Research.

[23]  D L Massart,et al.  An analysis of the Washington Conference Report on bioanalytical method validation. , 1994, Journal of pharmaceutical and biomedical analysis.

[24]  Robert W. Mee β-Expectation and β-Content Tolerance Limits for Balanced One-Way ANOVA Random Model , 1984 .

[25]  Charles R. Jensen Variance Component Calculations: Common Methods and Misapplications in the Semiconductor Industry , 2002 .

[26]  Roberto Gonçalves Junqueira,et al.  A procedure to assess linearity by ordinary least squares method , 2005 .

[27]  Avraham Lorber,et al.  Analytical figures of merit for tensorial calibration , 1997 .

[28]  Binodh DeSilva,et al.  Recommendations for the Bioanalytical Method Validation of Ligand-Binding Assays to Support Pharmacokinetic Assessments of Macromolecules , 2003, Pharmaceutical Research.

[29]  Jos H. Beijnen,et al.  BIOANALYTICAL LIQUID CHROMATOGRAPHIC METHOD VALIDATION. A REVIEW OF CURRENT PRACTICES AND PROCEDURES , 2000 .

[30]  F. E. Satterthwaite Synthesis of variance , 1941 .

[31]  J Ermer,et al.  Validation in pharmaceutical analysis. Part I: an integrated approach. , 2001, Journal of pharmaceutical and biomedical analysis.

[32]  P. Chiap,et al.  An analysis of the SFSTP guide on validation of chromatographic bioanalytical methods: progress and limitations. , 2003, Journal of pharmaceutical and biomedical analysis.

[33]  J. W. Findlay,et al.  Validation of immunoassays for bioanalysis: a pharmaceutical industry perspective. , 2000, Journal of pharmaceutical and biomedical analysis.

[34]  M Laurentie,et al.  Harmonization of strategies for the validation of quantitative analytical procedures. A SFSTP proposal--part II. , 2004, Journal of pharmaceutical and biomedical analysis.

[35]  K. Danzer,et al.  Selectivity in analytical chemistry (IUPAC Recommendations 2001) , 2001 .

[36]  D L Massart,et al.  Validation of bioanalytical chromatographic methods. , 1998, Journal of pharmaceutical and biomedical analysis.