Microwave ablation with multiple simultaneously powered small-gauge triaxial antennas: results from an in vivo swine liver model.

PURPOSE To prospectively investigate the ability of a single generator to power multiple small-diameter antennas and create large zones of ablation in an in vivo swine liver model. MATERIALS AND METHODS Thirteen female domestic swine (mean weight, 70 kg) were used for the study as approved by the animal care and use committee. A single generator was used to simultaneously power three triaxial antennas at 55 W per antenna for 10 minutes in three groups: a control group where antennas were spaced to eliminate ablation zone overlap (n=6; 18 individual zones of ablation) and experimental groups where antennas were spaced 2.5 cm (n=7) or 3.0 cm (n=5) apart. Animals were euthanized after ablation, and ablation zones were sectioned and measured. A mixed linear model was used to test for differences in size and circularity among groups. RESULTS Mean (+/-standard deviation) cross-sectional areas of multiple-antenna zones of ablation at 2.5- and 3.0-cm spacing (26.6 cm(2) +/- 9.7 and 32.2 cm(2) +/- 8.1, respectively) were significantly larger than individual ablation zones created with single antennas (6.76 cm(2) +/- 2.8, P<.001) and were 31% (2.5-cm spacing group: multiple antenna mean area, 26.6 cm(2); 3 x single antenna mean area, 20.28 cm(2)) to 59% (3.0-cm spacing group: multiple antenna mean area, 32.2 cm(2); 3 x single antenna mean area, 20.28 cm(2)) larger than 3 times the mean area of the single-antenna zones. Zones of ablation were found to be very circular, and vessels as large as 1.1 cm were completely coagulated with multiple antennas. CONCLUSION A single generator may effectively deliver microwave power to multiple antennas. Large volumes of tissue may be ablated and large vessels coagulated with multiple-antenna ablation in the same time as single-antenna ablation.

[1]  Andres Rahal,et al.  Radiofrequency ablation of hepatic tumors: variability of lesion size using a single ablation device. , 2004, AJR. American journal of roentgenology.

[2]  J. Webster,et al.  Large-volume radiofrequency ablation of ex vivo bovine liver with multiple cooled cluster electrodes. , 2005, Radiology.

[3]  Christopher L Brace,et al.  Microwave ablation with a single small-gauge triaxial antenna: in vivo porcine liver model. , 2007, Radiology.

[4]  D. Haemmerich,et al.  Multiple-electrode radiofrequency ablation: simultaneous production of separate zones of coagulation in an in vivo porcine liver model. , 2005, Journal of vascular and interventional radiology : JVIR.

[5]  Kazuyuki Saito,et al.  Heating characteristics of array applicator composed of two coaxial-slot antennas for microwave coagulation therapy , 2000 .

[6]  D. W. van der Weide,et al.  Microwave ablation with a triaxial antenna: results in ex vivo bovine liver , 2005, IEEE Transactions on Microwave Theory and Techniques.

[7]  Christopher L Brace,et al.  Multiple-electrode radiofrequency ablation creates confluent areas of necrosis: in vivo porcine liver results. , 2006, Radiology.

[8]  T. Winter,et al.  Effect of vascular occlusion on radiofrequency ablation of the liver: results in a porcine model. , 2001, AJR. American journal of roentgenology.

[9]  Dieter Haemmerich,et al.  Multiple probe radiofrequency ablation: pilot study in an animal model. , 2003, Journal of vascular and interventional radiology : JVIR.

[10]  S L Dawson,et al.  Tissue ablation with radiofrequency using multiprobe arrays. , 1995, Academic radiology.

[11]  David M. Mahvi,et al.  Hepatic Microwave Ablation With Multiple Antennae Results in Synergistically Larger Zones of Coagulation Necrosis , 2003, Annals of Surgical Oncology.