Wind turbine converter control interaction with complex wind farm systems

This study presents wind turbine converter stability analysis of wind farms in frequency domain. The interaction between the wind turbine control system and the wind farm structure in wind farms is deeply investigated. Two wind farms (i.e. Horns Rev II and Karnice) are taken into consideration in this study. It is shown that wind farm components, such as long high-voltage alternating current cables and park transformers, can introduce significant low-frequency series resonances seen from the wind turbine terminals that can affect wind turbine control system operation and overall wind farm stability. The same wind turbine converter control strategy is evaluated in two different wind farms. It is emphasised that the grid-side converter controller should be characterised by sufficient harmonic/noise rejection and adjusted depending on wind farms to which it is connected. Various stability indices such as gain margin, vector gain margin and phase margin are used in order to emphasise the differences between the two wind farms.

[1]  Frede Blaabjerg,et al.  Proportional-resonant controllers and filters for grid-connected voltage-source converters , 2006 .

[2]  D. G. Holmes,et al.  Frequency domain analysis of three phase linear current regulators , 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370).

[3]  Lukasz Hubert Kocewiak,et al.  Wind Farm Structures’ Impact on Harmonic Emission and Grid Interaction , 2010 .

[4]  M. Liserre,et al.  Stability of photovoltaic and wind turbine grid-connected inverters for a large set of grid impedance values , 2006, IEEE Transactions on Power Electronics.

[5]  Lukasz Hubert Kocewiak,et al.  Harmonics in large offshore wind farms , 2012 .

[6]  Hong-Seok Song,et al.  Dual current control scheme for PWM converter under unbalanced input voltage conditions , 1999, IEEE Trans. Ind. Electron..

[7]  M. García-Gracia,et al.  Modelling wind farms for grid disturbance studies , 2008 .

[8]  T. Undeland,et al.  Stationary frame voltage harmonic controller for standalone power generation , 2007, 2007 European Conference on Power Electronics and Applications.

[9]  P. N. Paraskevopoulos,et al.  Modern Control Engineering , 2001 .

[10]  P. Brogan The stability of multiple, high power, active front end voltage sourced converters when connected to wind farm collector systems , 2010 .

[11]  B. Anderson,et al.  Digital control of dynamic systems , 1981, IEEE Transactions on Acoustics, Speech, and Signal Processing.

[12]  C. Pritchard,et al.  European Wind Energy Conference , 2002 .

[13]  Luis M. Fernández,et al.  Equivalent models of wind farms by using aggregated wind turbines and equivalent winds , 2009 .

[14]  M. Liserre,et al.  Evaluation of Current Controllers for Distributed Power Generation Systems , 2009, IEEE Transactions on Power Electronics.

[15]  Gene F. Franklin,et al.  Feedback Control of Dynamic Systems , 1986 .