Analysis of defibrillation efficacy from myocardial voltage gradients with finite element modeling

Increasing defibrillation efficacy by lowering the defibrillation threshold (DFT) is an important goal in positioning implantable cardioverter-defibrillator electrodes. Clinically, the DFT is difficult to estimate noninvasively. It has been suggested that the DFT relates to the myocardial voltage gradient distribution, but this relation has not been quantitatively demonstrated. We analyzed the relation between the experimentally measured DFT's and the simulated myocardial voltage gradients provided by finite element modeling. We performed a series of experiments in 11 pigs to measure the DFT's, and created and solved three-dimensional subject-specific finite element models to assess the correlation between the computed myocardial voltage gradient histograms and the DFT's. Our data show a statistically significant correlation between the DFT and the left ventricular voltage gradient distribution, with the septal region being more significant (correlation coefficient of 0.74) than other myocardial regions. The correlation between the DFT and the right ventricular and the atrial voltage gradient, on the other hand, is not significant.

[1]  L A Geddes,et al.  Strength-duration curves for trapezoidal waveforms of various tilts for transchest defibrillation in animals. , 1978, Medical instrumentation.

[2]  Y Kim,et al.  Uniformity of current density under stimulating electrodes. , 1990, Critical reviews in biomedical engineering.

[3]  M Duriez,et al.  Reduction of Energy Required for Defibrillation by Delivering Shocks in Orthogonal Directions in the Dog , 1988, Pacing and clinical electrophysiology : PACE.

[4]  D P Zipes,et al.  Termination of ventricular fibrillation in dogs by depolarizing a critical amount of myocardium. , 1975, The American journal of cardiology.

[5]  S. Rush,et al.  Resistivity of Body Tissues at Low Frequencies , 1963, Circulation research.

[6]  J J Heger,et al.  Sudden cardiac death. , 1998, Circulation.

[7]  Yongmin Kim,et al.  An efficient tissue classifier for building patient-specific finite element models from X-ray CT images , 1996, IEEE Transactions on Biomedical Engineering.

[8]  Douglas L. Jones,et al.  Defibrillation Threshold: A Simple and Quantitative Estimate of the Ability to Defibrillate , 1987, Pacing and clinical electrophysiology : PACE.

[9]  I. Singer,et al.  Transseptal Defibrillation Is Superior for Transvenous Defibrillation , 1995, Pacing and clinical electrophysiology : PACE.

[10]  H. Schwan,et al.  Specific Resistance of Body Tissues , 1956, Circulation research.

[11]  L Tung,et al.  Influence of electrical axis of stimulation on excitation of cardiac muscle cells. , 1991, Circulation research.

[12]  J. G. Webster,et al.  Impedance of Skeletal Muscle from 1 Hz to 1 MHz , 1984, IEEE Transactions on Biomedical Engineering.

[13]  M. Scheinman,et al.  Determination of patch electrode position for the internal cardioverter-defibrillator by cine computed tomography and its relation to the defibrillation threshold. , 1992, Journal of the American College of Cardiology.

[14]  C S Henriquez,et al.  Finite element analysis of bioelectric phenomena. , 1990, Critical reviews in biomedical engineering.

[15]  P. Hunter,et al.  Mathematical model of geometry and fibrous structure of the heart. , 1991, The American journal of physiology.

[16]  R Plonsey,et al.  Mechanism of cardiac defibrillation in open-chest dogs with unipolar DC-coupled simultaneous activation and shock potential recordings. , 1990, Circulation.

[17]  P. Wolf,et al.  Defibrillation with Low Voltage using a Left Ventricular Catheter and Four Cutaneous Patch Electrodes in Dogs , 1991, Pacing and clinical electrophysiology : PACE.

[18]  B. Roth Mechanisms for electrical stimulation of excitable tissue. , 1994, Critical reviews in biomedical engineering.

[19]  R. Virmani,et al.  Sudden cardiac death. , 1987, Human pathology.

[20]  O. Zienkiewicz The Finite Element Method In Engineering Science , 1971 .

[21]  P. Kudenchuk,et al.  Clinical predictors of the defibrillation threshold with the unipolar implantable defibrillation system. , 1995, Journal of the American College of Cardiology.

[22]  J. Z. Zhu,et al.  The finite element method , 1977 .

[23]  J. H. Zar,et al.  Biostatistical Analysis (5th Edition) , 1984 .

[24]  George A. Johnson,et al.  Implantable transvenous cardioverter-defibrillators. , 1993, Circulation.

[25]  Robert Plonsey,et al.  The Four-Electrode Resistivity Technique as Applied to Cardiac Muscle , 1982, IEEE Transactions on Biomedical Engineering.

[26]  P. Wolf,et al.  Current Concepts for Selecting the Location, Size and Shape of Defibrillation Electrodes , 1991, Pacing and clinical electrophysiology : PACE.

[27]  J. Spear,et al.  Patterns of Ventricular Activity During Catheter Defibrillation , 1974, Circulation.

[28]  David W. Hosmer,et al.  Applied Logistic Regression , 1991 .

[29]  Yongmin Kim,et al.  Computational studies of transthoracic and transvenous defibrillation in a detailed 3-D human thorax model , 1995, IEEE Transactions on Biomedical Engineering.

[30]  ALAIN L. BARDOU,et al.  Directional Variability of Stimulation Threshold Measurements in Isolated Guinea Pig Cardiomyocytes: Relationship with Orthogonal Sequential Defibrillating Pulses , 1990, Pacing and clinical electrophysiology : PACE.

[31]  N. G. Sepulveda,et al.  Current injection into a two-dimensional anisotropic bidomain. , 1989, Biophysical journal.

[32]  P. Steendijk,et al.  The four-electrode resistivity technique in anisotropic media: theoretical analysis and application on myocardial tissue in vivo , 1993, IEEE Transactions on Biomedical Engineering.

[33]  D. Lang,et al.  Defibrillation Threshold: Clinical Utility and Therapeutic Implications , 1992, Pacing and clinical electrophysiology : PACE.

[34]  N. G. Sepulveda,et al.  Finite element analysis of cardiac defibrillation current distributions , 1990, IEEE Transactions on Biomedical Engineering.

[35]  Yongmin Kim,et al.  Optimal Electrode Designs for Electrosurgery, Defibrillation, and External Cardiac Pacing , 1986, IEEE Transactions on Biomedical Engineering.

[36]  F. Gielen,et al.  The electrical conductivity of skeletal muscle tissue. Experimental results of different muscles in vivo , 1984, Clinical Neurology and Neurosurgery.

[37]  G. Guiraudon,et al.  Sequential pulse defibrillation in humans: orthogonal sequential pulse defibrillation with epicardial electrodes. , 1988, Journal of the American College of Cardiology.

[38]  Yongmin Kim,et al.  Predicting cardiothoracic voltages during high energy shocks: methodology and comparison of experimental to finite element model data , 1995, IEEE Transactions on Biomedical Engineering.