Feature-Based Correlation and Topological Similarity for Interbeat Interval Estimation Using Ultrawideband Radar

The objectives of this paper are to propose a method that can accurately estimate the human heart rate (HR) using an ultrawideband (UWB) radar system, and to determine the performance of the proposed method through measurements. The proposed method uses the feature points of a radar signal to estimate the HR efficiently and accurately. Fourier- and periodicity-based methods are inappropriate for estimation of instantaneous HRs in real time because heartbeat waveforms are highly variable, even within the beat-to-beat interval. We define six radar waveform features that enable correlation processing to be performed quickly and accurately. In addition, we propose a feature topology signal that is generated from a feature sequence without using amplitude information. This feature topology signal is used to find unreliable feature points, and thus, to suppress inaccurate HR estimates. Measurements were taken using UWB radar, while simultaneously performing electrocardiography measurements in an experiment that was conducted on nine participants. The proposed method achieved an average root-mean-square error in the interbeat interval of 7.17 ms for the nine participants. The results demonstrate the effectiveness and accuracy of the proposed method. The significance of this study for biomedical research is that the proposed method will be useful in the realization of a remote vital signs monitoring system that enables accurate estimation of HR variability, which has been used in various clinical settings for the treatment of conditions such as diabetes and arterial hypertension.

[1]  Olga Boric-Lubecke,et al.  0.5-$\mu\hbox{m}$ CMOS Implementation of Analog Heart-Rate Extraction With a Robust Peak Detector , 2008, IEEE Transactions on Instrumentation and Measurement.

[2]  Robert Weigel,et al.  Six-Port Radar Sensor for Remote Respiration Rate and Heartbeat Vital-Sign Monitoring , 2013, IEEE Transactions on Microwave Theory and Techniques.

[3]  Seong-Ook Park,et al.  Noninvasive Biosignal Detection Radar System Using Circular Polarization , 2009, IEEE Transactions on Information Technology in Biomedicine.

[4]  B. Fetics,et al.  Prognostic value of heart rate variability in chronic congestive heart failure (Veterans Affairs' Survival Trial of Antiarrhythmic Therapy in Congestive Heart Failure). , 2002, The American journal of cardiology.

[5]  Byung-Kwon Park,et al.  Arctangent Demodulation With DC Offset Compensation in Quadrature Doppler Radar Receiver Systems , 2007, IEEE Transactions on Microwave Theory and Techniques.

[6]  Aggelos K. Katsaggelos,et al.  Noncontact Millimeter-Wave Real-Time Detection and Tracking of Heart Rate on an Ambulatory Subject , 2012, IEEE Transactions on Information Technology in Biomedicine.

[7]  Changzhi Li,et al.  1-D Microwave Imaging of Human Cardiac Motion: An Ab-Initio Investigation , 2013, IEEE Transactions on Microwave Theory and Techniques.

[8]  Stefano Tomasin,et al.  ML Period Estimation With Application to Vital Sign Monitoring , 2010, IEEE Signal Processing Letters.

[9]  O. Boric-Lubecke,et al.  Assessment of Heart Rate Variability and Respiratory Sinus Arrhythmia via Doppler Radar , 2009, IEEE Transactions on Microwave Theory and Techniques.

[10]  A. Yarovoy,et al.  Experimental study on human breathing cross section using UWB impulse radar , 2008, 2008 European Radar Conference.

[11]  Atsushi Mase,et al.  Measurement of heart rate variability and stress evaluation by using microwave reflectometric vital signal sensing. , 2010, The Review of scientific instruments.

[12]  Jing Li,et al.  Advanced Signal Processing for Vital Sign Extraction With Applications in UWB Radar Detection of Trapped Victims in Complex Environments , 2014, IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing.

[13]  Wei Hu,et al.  Noncontact Accurate Measurement of Cardiopulmonary Activity Using a Compact Quadrature Doppler Radar Sensor , 2014, IEEE Transactions on Biomedical Engineering.

[14]  Jiguang Sun,et al.  Through-Wall Detection of Human Being's Movement by UWB Radar , 2012, IEEE Geoscience and Remote Sensing Letters.

[15]  A. F. Molisch,et al.  Propagation Parameter Estimation, Modeling and Measurements for Ultrawideband MIMO Radar , 2011, IEEE Transactions on Antennas and Propagation.

[16]  Jian Li,et al.  Accurate Doppler Radar Noncontact Vital Sign Detection Using the RELAX Algorithm , 2010, IEEE Transactions on Instrumentation and Measurement.

[17]  Jenshan Lin,et al.  Range correlation and I/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring , 2004, IEEE Transactions on Microwave Theory and Techniques.

[18]  O. Boric-Lubecke,et al.  A digital signal processor for Doppler radar sensing of vital signs , 2001, 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[19]  H. Schumacher,et al.  IR-UWB Radar Demonstrator for Ultra-Fine Movement Detection and Vital-Sign Monitoring , 2013, IEEE Transactions on Microwave Theory and Techniques.

[20]  Janko Drnovsek,et al.  Novel Methods for Noncontact Heart Rate Measurement: A Feasibility Study , 2014, IEEE Transactions on Instrumentation and Measurement.

[21]  Fukuda Takeshi,et al.  A 26GHz Short-Range UWB Vehicular-Radar Using 2.5Gcps Spread Spectrum Modulation , 2008 .

[22]  Hee Chan Kim,et al.  Heart Rate Tracking Using a Doppler Radar With the Reassigned Joint Time-Frequency Transform , 2011, IEEE Antennas and Wireless Propagation Letters.

[23]  Alan V. Sahakian,et al.  Remote Sensing of Heart Rate and Patterns of Respiration on a Stationary Subject Using 94-GHz Millimeter-Wave Interferometry , 2011, IEEE Transactions on Biomedical Engineering.

[24]  Paolo Bernardi,et al.  Design, Realization, and Test of a UWB Radar Sensor for Breath Activity Monitoring , 2014, IEEE Sensors Journal.

[25]  Cheong Boon Soh,et al.  Wireless Sensing of Human Respiratory Parameters by Low-Power Ultrawideband Impulse Radio Radar , 2011, IEEE Transactions on Instrumentation and Measurement.

[26]  Shaolin Liao,et al.  A real-time heart rate analysis for a remote millimeter wave I-Q sensor , 2011, IEEE Transactions on Biomedical Engineering.

[27]  Zhao Qi Prognostic value of heart rate variability on chronic congestive heart failure , 2002 .

[28]  J. Lin,et al.  Experiment and Spectral Analysis of a Low-Power $Ka$-Band Heartbeat Detector Measuring From Four Sides of a Human Body , 2006, IEEE Transactions on Microwave Theory and Techniques.

[29]  M. Zakrzewski,et al.  Comparison of Center Estimation Algorithms for Heart and Respiration Monitoring With Microwave Doppler Radar , 2012, IEEE Sensors Journal.