Cooling performance of a vertical ground-coupled heat pump system installed in a school building

This paper presents the cooling performance of a water-to-refrigerant type ground heat source heat pump system (GSHP) installed in a school building in Korea. The evaluation of the cooling performance has been conducted under the actual operation of GSHP system in the summer of year 2007. Ten heat pump units with the capacity of 10HP each were installed in the building. Also, a closed vertical typed-ground heat exchanger with 24 boreholes of 175m in depth was constructed for the GSHP system. To analyze the cooling performance of the GSHP system, we monitored various operating conditions, including the outdoor temperature, the ground temperature, and the water temperature of inlet and outlet of the ground heat exchanger. Simultaneously, the cooling capacity and the input power were evaluated to determine the cooling performance of the GSHP system. The average cooling coefficient of performance (COP) and overall COP of the GSHP system were found to be ∼8.3 and ∼5.9 at 65% partial load condition, respectively. While the air source heat pump (ASHP) system, which has the same capacity with the GSHP system, was found to have the average COP of ∼3.9 and overall COP of ∼3.4, implying that the GSHP system is more efficient than the ASHP system due to its lower temperature of condenser.

[1]  V. I. Ugursal,et al.  Performance and economic feasibility of ground source heat pumps in cold climate , 1997 .

[2]  Josua P. Meyer,et al.  A performance comparison between an air‐source and a ground‐source reversible heat pump , 2001 .

[3]  Anastassios M. Stamatelos,et al.  Effect of climatic conditions on the design optimization of heat pump systems for space heating and cooling , 1998 .

[4]  Apostolos Michopoulos,et al.  Three-years operation experience of a ground source heat pump system in Northern Greece , 2007 .

[5]  Nurdan Yildirim,et al.  District heating system design for a university campus , 2006 .

[6]  Sohn Byong Hu,et al.  Cooling and Heating Performance Evaluation of a GSHP System , 2005 .

[7]  Saffa Riffat,et al.  Ground source heat pump––description and preliminary results of the Eco House system , 2004 .

[8]  Li Zhao,et al.  Influence of two systematic parameters on the geothermal heat pump system operation , 2003 .

[9]  Katsunori Nagano,et al.  Development of a design and performance prediction tool for the ground source heat pump system , 2006 .

[10]  Arif Hepbasli,et al.  Experimental study of a closed loop vertical ground source heat pump system , 2003 .

[11]  Josua P. Meyer,et al.  Economic potential of vertical ground-source heat pumps compared to air-source air conditioners in South Africa , 1998 .

[12]  Li Zhao,et al.  Experimental evaluation of a non-azeotropic working fluid for geothermal heat pump system , 2004 .