Buildings with environmental quality management, part 2: Integration of hydronic heating/cooling with thermal mass

The quest for a sustainable built environment brought dramatic changes to architectural design because of the integrated design process. The integrated design process is the modern way to realize “performance architecture,” that is, design with a view to field performance. Integrated design process permits merging of concepts from passive-house designs, solar engineering, and an integration of the building enclosure with mechanical services. In part 1 of this series, the emergence of many new multi-functional materials was discussed. Yet, current innovation is guided by lessons from history. Thermal mass in heavy masonry buildings allowed periodic heating. The authors postulate integration of a hydronic heating system with the walls and the use of smart temperature control of the heating system to modify and optimize the thermal mass contribution. To use the mass of a building, one must accept transient temperature conditions where the indoor temperature varies but is confined by comfort requirements for both summer and winter conditions. On the other side, resiliency requirements dictate that in the absence of electricity the air temperature does not fall below about 12°C over a period of several hours. This requirement implies that summer cooling will likely be separated from the heating systems and that operation of a low-energy building is heavily dependent on the design of smart control systems. Analysis of control systems provided in this article for earth-to-air heat exchangers and cooling of houses with lightweight walls lead us to the requirements of separation between heating and ventilation and needs for different sources of fresh air. Finally, a new concept emerges.

[2]  Md. Shazib Uddin,et al.  Performance evaluation and life cycle analysis of earth to air heat exchanger in a developing country , 2016 .

[3]  Marcin Furtak,et al.  Cooperation of Horizontal Ground Heat Exchanger with the Ventilation Unit During Summer - Case Study , 2017 .

[4]  Terry Brennan,et al.  QUALITY ASSURANCE AND COMMISSIONING PROCESS IN HIGH ENVIRONMENTAL PERFORMANCE (HEP) HOUSE IN NY STATE , 2008 .

[5]  Michele De Carli,et al.  The design and environmental evaluation of earth-to-air heat exchangers (EAHE). A literature review , 2013 .

[6]  Jens Pfafferott,et al.  Evaluation of earth-to-air heat exchangers with a standardised method to calculate energy efficiency , 2003 .

[7]  Jan Radoń,et al.  Experimental measurements and CFD simulation of a ground source heat exchanger operating at a cold climate for a passive house ventilation system , 2014 .

[9]  Guohui Gan,et al.  Dynamic interactions between the ground heat exchanger and environments in earth–air tunnel ventilation of buildings , 2014 .

[10]  Jian Zhang,et al.  A concept of integrated environmental approach for building upgrades and new construction: Part 1—setting the stage , 2015 .

[11]  Maneesh Kaushal,et al.  Geothermal cooling/heating using ground heat exchanger for various experimental and analytical studies: Comprehensive review , 2017 .

[13]  Robert Wójcik,et al.  A concept of integrated environmental approach, Part 2: Integrated approach to rehabilitation , 2016 .

[14]  Maria Grazia De Giorgi,et al.  Horizontal Air-Ground Heat Exchanger Performance and Humidity Simulation by Computational Fluid Dynamic Analysis , 2016 .

[15]  David W. Yarbrough,et al.  Buildings with environmental quality management: Part 1: Designing multifunctional construction materials , 2017 .

[16]  Adrian Badea,et al.  The historical evolution of the energy efficient buildings , 2015 .

[17]  Mark Bomberg,et al.  Heat, Air and Moisture Control in Walls of Canadian Houses: A Review of the Historic Basis for Current Practices , 2002 .