Ultrasonographic movement of the flexor pollicis longus tendon before and after removal of a volar plate for the distal radius fracture

Introduction: The purpose of this study was to compare the movement of the flexor pollicis longus (FPL) tendon on the distal radius during wrist and finger motions before and after removal of a volar plate in patients with distal radius fractures using transverse ultrasound and to evaluate the kinematic effects on the FPL by the removal. Methods: Twenty-five patients with distal radius fracture were evaluated quantitatively by transverse ultrasound using coordinates for the movement of the FPL on the distal radius during wrist and finger motions before and after the plate removal. Results: At all wrist positions, during finger motion, the FPL moved significantly more palmarly away from the radius after plate removal compared to before. However, the FPL was still situated more dorsoulnarly compared with unaffected side. Moreover, the FPL moved significantly most dorsally both before and after removal at the wrist dorsal flexion position with finger flexion. Conclusions: These findings suggested that any adhesion between the FPL and the pronator quadratus (PQ) muscle was released by removing the plate and that the FPL would approach original tendon movement. Additionally, it is speculated that any remaining atrophy and fibrosis of the PQ may be the reason for more dorsoulnar location of the FPL in the affected side compared with the unaffected one. This ultrasound evaluation may be useful in further understanding the FPL kinematics on the distal radius, and in appropriate treatment of the distal radius fracture with plate fixation for preventing FPL rupture.

[1]  M. Takagi,et al.  Ultrasonographic Assessment of the Flexor Pollicis Longus Tendon After Plate Fixation. , 2017, Orthopedics.

[2]  S. Takai,et al.  Ultrasound Evaluation of the Transverse Movement of the Flexor Pollicis Longus Tendon on the Distal Radius during Wrist and Finger Motion in Healthy Volunteers. , 2015, Journal of Nippon Medical School = Nippon Ika Daigaku zasshi.

[3]  H. Kato,et al.  Risk Assessment of Tendon Attrition Following Treatment of Distal Radius Fractures With Volar Locking Plates Using Audible Crepitus and Placement of the Plate: A Prospective Clinical Cohort Study. , 2015, The Journal of hand surgery.

[4]  S. Takai,et al.  Transverse ultrasound assessment of the flexor pollicis longus tendon movement on the distal radius during wrist and finger motion in distal radius fracture with volar plating , 2015, Journal of Medical Ultrasonics.

[5]  A. Weiland,et al.  Volar plate position and flexor tendon rupture following distal radius fracture fixation. , 2013, The Journal of hand surgery.

[6]  S. Asadollahi,et al.  Flexor tendon injuries following plate fixation of distal radius fractures: a systematic review of the literature , 2013, Journal of Orthopaedics and Traumatology.

[7]  K. Song,et al.  Delayed Rupture of Flexor Pollicis Longus after Volar Plating for a Distal Radius Fracture , 2012, Clinics in orthopedic surgery.

[8]  H. Tsuchiya,et al.  Prevention of flexor pollicis longus tendon rupture after volar plate fixation of distal radius fractures. , 2011, Hand surgery : an international journal devoted to hand and upper limb surgery and related research : journal of the Asia-Pacific Federation of Societies for Surgery of the Hand.

[9]  M. Fujimiya,et al.  Effect of distal radius volar plate position on contact pressure between the flexor pollicis longus tendon and the distal plate edge. , 2011, The Journal of hand surgery.

[10]  P. Blazar,et al.  Volar locking plate implant prominence and flexor tendon rupture. , 2011, The Journal of bone and joint surgery. American volume.

[11]  D. Brown,et al.  Flexor Pollicis Longus Tendon Ruptures after Palmar Plate Fixation of Fractures of the Distal Radius , 2009, The Journal of hand surgery, European volume.

[12]  D. Dennison Flexor Tendon Injuries Following Locked Volar Plating of Distal Radius Fractures , 2009 .

[13]  G. Athwal,et al.  Complications Following Internal Fixation of Unstable Distal Radius Fracture With a Palmar Locking-Plate , 2008 .

[14]  A. Touhami,et al.  Current concepts in volar fixed-angle fixation of unstable distal radius fractures. , 2006, Clinical orthopaedics and related research.

[15]  H. Drobetz,et al.  Osteosynthesis of distal radial fractures with a volar locking screw plate system , 2002, International Orthopaedics.