Sensitivity Based Network Contingency Ranking Using Newton Raphson Power Flow Method

In the area of power system planning and operation, contingency analysis plays an important role. In the present days, on-line security assessment is done by contingency ranking, with the help of various computer software, incorporating iterative method like Newton Raphson power flow for obtaining the magnitudes of different parameters. The motive of contingency ranking is to create a short list of potential contingencies quickly and rank them according to their severity in an accurate manner. In this paper sensitivity based wide performance index with respect to outage have been presented. The Newton-Raphson power flow results were used to construct two kinds of performance indices, namely the real power performance index and voltage performance index, which reflect the degree of severity of contingencies. Then full AC load flow was performed for each contingency case, to study the contingency effect. The effectiveness of the proposed method has been demonstrated by contingency screening and ranking on a standard 6-bus and IEEE 14-bus system.

[1]  John Zaborszky,et al.  Fast Contingency Evaluation Using Concentric Relaxation , 1980, IEEE Transactions on Power Apparatus and Systems.

[2]  O. Alsac,et al.  Security analysis and optimization , 1987, Proceedings of the IEEE.

[3]  Seema Singh,et al.  Improved voltage and reactive power distribution factors for outage studies , 1997 .

[4]  K. Shanti Swarup,et al.  Neural network approach to contingency screening and ranking in power systems , 2006, Neurocomputing.

[5]  A. Bose,et al.  Reactive Power Considerations in Automatic Contingency Selection , 1982, IEEE Transactions on Power Apparatus and Systems.

[6]  L. Vanfretti,et al.  Application of the PSAT, an Open Source Software, for Educational and Research Purposes , 2007, 2007 IEEE Power Engineering Society General Meeting.

[7]  G. Ejebe,et al.  Automatic Contingency Selection , 1979, IEEE Transactions on Power Apparatus and Systems.

[8]  V. Brandwajn,et al.  Complete Bounding Method for AC Contingency Screening , 1989, IEEE Power Engineering Review.

[9]  R. Gnanadass,et al.  Fuzzy based contingency assessment using performance indices with masking effect , 2012, 2012 IEEE Students' Conference on Electrical, Electronics and Computer Science.

[10]  K. Carlsen,et al.  Operating under stress and strain [electrical power systems control under emergency conditions] , 1978, IEEE Spectrum.

[11]  Nanming Chen,et al.  Distribution factors of reactive power flow in transmission line and transformer outage studies , 1992 .