Effects of restricted diffusion on MR signal formation.

Numerous functional MRI (fMRI) and diffusion MR studies have recently boosted interest in the theory of MR signal formation in biological systems in the presence of mesoscopic magnetic field in homogeneities. Herein we report an exact solution to the problem of free induction decay (FID) and spin echo (SE) signal formation in the presence of a constant field gradient in three models of one-, two-, and three-dimensional restricted diffusion. We demonstrate the transition with increasing diffusion coefficient from the oscillating FID signal behavior in the static dephasing regime to a monotonic exponential behavior in the motional narrowing regime. Quantitative criteria are presented for applicability of the Gaussian approximation for the description of the MR signal. The spatial distribution of signal density and the edge enhancement effect are analyzed. We also demonstrate that the presence of restrictive barriers in a one-compartment model can lead to a quasi-two-compartment behavior of the MR signal. This result suggests a simple rationale for the experimental findings of biexponential echo attenuation curves in MR diffusion experiments with tissue systems.

[1]  H. Carr,et al.  The Principles of Nuclear Magnetism , 1961 .

[2]  E. Haacke,et al.  Theory of NMR signal behavior in magnetically inhomogeneous tissues: The static dephasing regime , 1994, Magnetic resonance in medicine.

[3]  S. Ogawa,et al.  Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields , 1990, Magnetic resonance in medicine.

[4]  Eiichi Fukushima,et al.  Simple Solutions of the Torrey–Bloch Equations in the NMR Study of Molecular Diffusion , 1997 .

[5]  W. Happer,et al.  EDGE ENHANCEMENT OBSERVED WITH HYPERPOLARIZED 3HE , 1996 .

[6]  B. Rosen,et al.  Microscopic susceptibility variation and transverse relaxation: Theory and experiment , 1994, Magnetic resonance in medicine.

[7]  Baldwin Robertson,et al.  Spin-Echo Decay of Spins Diffusing in a Bounded Region , 1966 .

[8]  D. Norris,et al.  Biexponential diffusion attenuation in various states of brain tissue: Implications for diffusion‐weighted imaging , 1996, Magnetic resonance in medicine.

[9]  Per Linse,et al.  The NMR Self-Diffusion Method Applied to Restricted Diffusion. Simulation of Echo Attenuation from Molecules in Spheres and between Planes , 1993 .

[10]  Paul T. Callaghan,et al.  Pulsed gradient spin echo nuclear magnetic resonance for molecules diffusing between partially reflecting rectangular barriers , 1994 .

[11]  J. Neil,et al.  Evidence that both fast and slow water ADC components arise from intracellular space , 2002, Magnetic resonance in medicine.

[12]  D L Buckley,et al.  Visualization of neural tissue water compartments using biexponential diffusion tensor MRI , 2001, Magnetic resonance in medicine.

[13]  Paul C. Lauterbur,et al.  Effects of restricted diffusion on microscopic NMR imaging , 1991 .

[14]  What are the conditions for exponential time-cubed echo decays? , 1999, Journal of magnetic resonance.

[15]  Dyson,et al.  Transverse spin relaxation in inhomogeneous magnetic fields. , 1991, Physical review. A, Atomic, molecular, and optical physics.

[16]  M. H. Blees,et al.  The Effect of Finite Duration of Gradient Pulses on the Pulsed-Field-Gradient NMR Method for Studying Restricted Diffusion , 1994 .

[17]  E. Purcell,et al.  Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments , 1954 .

[18]  Eiichi Fukushima,et al.  A Multiple-Narrow-Pulse Approximation for Restricted Diffusion in a Time-Varying Field Gradient , 1996 .

[19]  P. Callaghan,et al.  Diffusive relaxation and edge enhancement in NMR microscopy , 1993 .

[20]  D. Yablonskiy,et al.  Quantitation of intrinsic magnetic susceptibility‐related effects in a tissue matrix. Phantom study , 1998, Magnetic resonance in medicine.

[21]  C. H. Neuman Spin echo of spins diffusing in a bounded medium , 1974 .

[22]  B R Rosen,et al.  Mr contrast due to intravascular magnetic susceptibility perturbations , 1995, Magnetic resonance in medicine.

[23]  S. Posse,et al.  Analytical model of susceptibility‐induced MR signal dephasing: Effect of diffusion in a microvascular network , 1999, Magnetic resonance in medicine.

[24]  I. S. Gradshteyn,et al.  Table of Integrals, Series, and Products , 1976 .

[25]  Scott N. Hwang,et al.  Biexponential diffusion attenuation in the rat spinal cord: Computer simulations based on anatomic images of axonal architecture , 2002, Magnetic resonance in medicine.

[26]  J C Gore,et al.  Asymmetric spin‐echo imaging of magnetically inhomogeneous systems: Theory, experiment, and numerical studies , 1998, Magnetic resonance in medicine.

[27]  Callaghan,et al.  Spin Echo Analysis of Restricted Diffusion under Generalized Gradient Waveforms: Planar, Cylindrical, and Spherical Pores with Wall Relaxivity. , 1999, Journal of magnetic resonance.

[28]  F. Wehrli,et al.  Magnetic field distribution in models of trabecular bone , 1993, Magnetic resonance in medicine.

[29]  A. Sukstanskii,et al.  Theory of FID NMR signal dephasing induced by mesoscopic magnetic field inhomogeneities in biological systems. , 2001, Journal of magnetic resonance.

[30]  P. Callaghan Principles of Nuclear Magnetic Resonance Microscopy , 1991 .

[31]  D L Buckley,et al.  The effect of ouabain on water diffusion in the rat hippocampal slice measured by high resolution NMR imaging , 1999, Magnetic resonance in medicine.

[32]  J. C. Jaeger,et al.  Conduction of Heat in Solids , 1952 .

[33]  H. C. Torrey Bloch Equations with Diffusion Terms , 1956 .

[34]  Per Linse,et al.  The Validity of the Short-Gradient-Pulse Approximation in NMR Studies of Restricted Diffusion. Simulations of Molecules Diffusing between Planes, in Cylinders and Spheres , 1995 .

[35]  T. M. Deswiet Diffusive Edge Enhancement in Imaging , 1995 .

[36]  Y. Cohen,et al.  Non-mono-exponential attenuation of water and N-acetyl aspartate signals due to diffusion in brain tissue. , 1998, Journal of magnetic resonance.

[37]  D. Le Bihan,et al.  Water diffusion compartmentation and anisotropy at high b values in the human brain , 2000, Magnetic resonance in medicine.

[38]  Callaghan,et al.  A simple matrix formalism for spin echo analysis of restricted diffusion under generalized gradient waveforms , 1997, Journal of magnetic resonance.

[39]  Klaus Schulten,et al.  Edge enhancement by diffusion in microscopic magnetic resonance imaging , 1992 .

[40]  V. G. Kiselev,et al.  ANALYTICAL THEORY OF SUSCEPTIBILITY INDUCED NMR SIGNAL DEPHASING IN A CEREBROVASCULAR NETWORK , 1998 .

[41]  J. Gore,et al.  Intravascular susceptibility contrast mechanisms in tissues , 1994, Magnetic resonance in medicine.

[42]  P. Sen,et al.  Decay of nuclear magnetization by bounded diffusion in a constant field gradient , 1994 .