Biomechanical Analysis of Force Distribution in Human Finger Extensor Mechanisms

The complexities of the function and structure of human fingers have long been recognised. The in vivo forces in the human finger tendon network during different activities are critical information for clinical diagnosis, surgical treatment, prosthetic finger design, and biomimetic hand development. In this study, we propose a novel method for in vivo force estimation for the finger tendon network by combining a three-dimensional motion analysis technique and a novel biomechanical tendon network model. The extensor mechanism of a human index finger is represented by an interconnected tendinous network moving around the phalanx's dorsum. A novel analytical approach based on the “Principle of Minimum Total Potential Energy” is used to calculate the forces and deformations throughout the tendon network of the extensor mechanism when subjected to an external load and with the finger posture defined by measurement data. The predicted deformations and forces in the tendon network are in broad agreement with the results obtained by previous experimental in vitro studies. The proposed methodology provides a promising tool for investigating the biomechanical function of complex interconnected tendon networks in vivo.

[1]  Edmund Y. S. Chao,et al.  GRAPHICAL INTERPRETATION OF THE SOLUTION TO THE REDUNDANT PROBLEM IN BIOMECHANICS. , 1978 .

[2]  Franck Quaine,et al.  Estimation of finger muscle tendon tensions and pulley forces during specific sport-climbing grip techniques. , 2006, Journal of biomechanics.

[3]  J L Sancho-Bru,et al.  A 3-D dynamic model of human finger for studying free movements. , 2001, Journal of biomechanics.

[4]  Francisco J Valero-Cuevas,et al.  An Integrative Approach to the Biomechanical Function and Neuromuscular Control of the Fingers , 2004 .

[5]  J Mizrahi,et al.  A biomechanical model of index finger dynamics. , 1995, Medical engineering & physics.

[6]  K. An,et al.  Extensor mechanism of the fingers. I. A quantitative geometric study. , 1991, The Journal of hand surgery.

[7]  Siaw Meng Chou,et al.  Development of a finger biomechanical model and its considerations. , 2010, Journal of biomechanics.

[8]  V M Zatsiorsky,et al.  The effect of finger extensor mechanism on the flexor force during isometric tasks. , 2001, Journal of biomechanics.

[9]  O HALLEN On the cutting and thickness determination of microtome sections; a study in quantitative cytology. , 1955, Acta anatomica. Supplementum.

[10]  A A Amis,et al.  Finger joint force predictions related to design of joint replacements. , 1982, Journal of biomedical engineering.

[11]  Franck Quaine,et al.  Using EMG data to constrain optimization procedure improves finger tendon tension estimations during static fingertip force production. , 2007, Journal of biomechanics.

[12]  J. P. Paul,et al.  A biomechanical analysis of the metacarpo-phalangeal joint , 1977 .

[13]  K. An,et al.  Extensor mechanism of the fingers. II. Tensile properties of components. , 1991, The Journal of hand surgery.

[14]  E. Chao,et al.  Biomechanical analysis of static forces in the thumb during hand function. , 1977, The Journal of bone and joint surgery. American volume.

[15]  Eaton Rg The extensor mechanism of the fingers. , 1969 .

[16]  David Howard,et al.  Biomechanical Analysis of the Human Finger Extensor Mechanism during Isometric Pressing , 2014, PloS one.

[17]  V M Zatsiorsky,et al.  Contribution of the extrinsic and intrinsic hand muscles to the moments in finger joints. , 2000, Clinical biomechanics.

[18]  E Y Chao,et al.  Three-dimensional force analysis of finger joints in selected isometric hand functions. , 1976, Journal of biomechanics.

[19]  Francisco J. Valero Cuevas,et al.  Beyond Parameter Estimation: Extending Biomechanical Modeling by the Explicit Exploration of Model Topology , 2007, IEEE Transactions on Biomedical Engineering.

[20]  N K Fowler,et al.  Interphalangeal joint and tendon forces: normal model and biomechanical consequences of surgical reconstruction. , 2000, Journal of biomechanics.

[21]  F. Zajac,et al.  Large index-fingertip forces are produced by subject-independent patterns of muscle excitation. , 1998, Journal of biomechanics.

[22]  F.J. Valero-Cuevas,et al.  A computational environment to simulate complex tendinous topologies , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[23]  R. L. Linscheid,et al.  Forces in the normal and abnormal hand , 1985, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[24]  Hod Lipson,et al.  A Relaxation Method for Simulating the Kinematics of Compound Nonlinear , 2006 .

[25]  J. Leijnse Why the lumbrical muscle should not be bigger--a force model of the lumbrical in the unloaded human finger. , 1997, Journal of biomechanics.

[26]  K N An,et al.  Normative model of human hand for biomechanical analysis. , 1979, Journal of biomechanics.

[27]  J. Landsmeer Anatomical and functional investigations on the articulation of the human fingers. , 1955, Acta anatomica. Supplementum.

[28]  B M Hillberry,et al.  Finger joint force minimization in pianists using optimization techniques. , 1993, Journal of biomechanics.