Resolution improvement and noise reduction in human pinhole SPECT using a multi-ray approach and the SHINE method

PURPOSE This work aimed at quantifying the gains in spatial resolution and noise that could be achieved when using resolution modelling based on a multi-ray approach and additionally the Statistical and Heuristic Noise Extraction (SHINE) method in human pinhole single photon emission tomography (PH-SPECT). METHODS PH-SPECT of two line phantoms and one homogeneous cylinder were recorded using parameters suited for studies of the human neck area. They were reconstructed using pinhole dedicated ordered subsets expectation maximisation algorithm including a resolution recovery technique based on 7 or 21 rays. Optionally, the SPECT data were SHINE pre-processed. Transverse and axial full widths at half-maximum (FWHM) were obtained from the line phantoms. The noise was quantified using the coefficient of variation (COV) derived from the uniform phantom. Two human PH-SPECT studies of the thyroid (a hot nodule and a very low uptake) were processed with the same algorithms. RESULTS Depending on the number of iterations, FWHM decreased by 30 to 50% when using the multi-ray approach in the reconstruction process. The SHINE method did not affect the resolution but decreased the COV by at least 20% and by 45% when combined with the multi-ray method. The two human studies illustrated the gain in spatial resolution and the decrease in noise afforded both by the multi-ray reconstruction and the SHINE method. CONCLUSION Iterative reconstruction with resolution modelling allows to obtain high resolution human PH-SPECT studies with reduced noise content. The SHINE method affords an additional noise reduction without compromising the resolution.

[1]  Antonio Cossu,et al.  The usefulness of neck pinhole SPECT as a complementary tool to planar scintigraphy in primary and secondary hyperparathyroidism. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[2]  A. Seret,et al.  99mTc-MIBI pinhole SPECT in primary hyperparathyroidism: comparison with conventional SPECT, planar scintigraphy and ultrasonography , 2008, European Journal of Nuclear Medicine and Molecular Imaging.

[3]  Frans van der Have,et al.  The pinhole: gateway to ultra-high-resolution three-dimensional radionuclide imaging , 2007, European Journal of Nuclear Medicine and Molecular Imaging.

[4]  Alain Seret,et al.  180° Pinhole SPET with a tilted detector and OS-EM reconstruction: phantom studies and potential clinical applications , 2001, European Journal of Nuclear Medicine.

[5]  Vladimir Y. Panin,et al.  Fully 3-D PET reconstruction with system matrix derived from point source measurements , 2006, IEEE Transactions on Medical Imaging.

[6]  Ulla Ruotsalainen,et al.  Accelerated median root prior reconstruction for pinhole single-photon emission tomography (SPET). , 2003, Physics in medicine and biology.

[7]  P M Wanet,et al.  Physical and clinical evaluation of high-resolution thyroid pinhole tomography. , 1996, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  Ora Israel,et al.  Technetium-99m-MIBI SPECT/CT in Primary Hyperparathyroidism , 2005, World Journal of Surgery.

[9]  Michel Defrise,et al.  Interest of the ordered subsets expectation maximization (OS-EM) algorithm in pinhole single-photon emission tomography reconstruction: a phantom study , 2000, European Journal of Nuclear Medicine.

[10]  Alain Seret,et al.  Will high-resolution/high-sensitivity SPECT ensure that PET is not the only survivor in nuclear medicine during the next decade? , 2009, European Journal of Nuclear Medicine and Molecular Imaging.

[11]  H. Amthauer,et al.  Impact of image fusion and attenuation correction by SPECT-CT on the scintigraphic detection of parathyroid adenomas , 2007, Nuklearmedizin.

[12]  D. Huić,et al.  Geometric models in dosimetry of thyroid remnant mass , 2008, Nuklearmedizin.

[13]  Ulla Ruotsalainen,et al.  Improving the quality of small animal brain pinhole SPECT imaging by Bayesian reconstruction , 2004, European Journal of Nuclear Medicine and Molecular Imaging.

[14]  Hiroyuki Kudo,et al.  A new reconstruction strategy for image improvement in pinhole SPECT , 2004, European Journal of Nuclear Medicine and Molecular Imaging.

[15]  Paul Suetens,et al.  Optimization of geometrical calibration in pinhole SPECT , 2005, IEEE Transactions on Medical Imaging.

[16]  Patrick Dupont,et al.  Characterization of pinhole SPECT acquisition geometry , 2003, IEEE Transactions on Medical Imaging.

[17]  B.M.W. Tsui,et al.  Three-dimensional Iterative Reconstruction Algorithms With Attenuation And Geometric Point Response Correction , 1990, 1990 IEEE Nuclear Science Symposium Conference Record.

[18]  Grant T. Gullberg,et al.  Slab-by-slab blurring model for geometric point response correction and attenuation correction using iterative reconstruction algorithms , 1997, 1997 IEEE Nuclear Science Symposium Conference Record.

[19]  P. Hannequin,et al.  Statistical and heuristic image noise extraction (SHINE): a new method for processing Poisson noise in scintigraphic images. , 2002, Physics in medicine and biology.

[20]  D. Weber,et al.  Ultra-high-resolution imaging of small animals: Implications for preclinical and research studies , 1999, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[21]  Antti Sohlberg,et al.  Comparison of multi-ray and point-spread function based resolution recovery methods in pinhole SPECT reconstruction , 2006, Nuclear medicine communications.

[22]  Johan Nuyts,et al.  Resolution recovery in pinhole SPECT based on multi-ray projections: a phantom study , 2007, European Journal of Nuclear Medicine and Molecular Imaging.

[23]  Alain Seret,et al.  Body contour 180° pinhole SPET with or without tilted detector: a phantom study , 2003, European Journal of Nuclear Medicine and Molecular Imaging.

[24]  J. Hoppin,et al.  Molecular imaging of reduced renal uptake of radiolabelled [DOTA0,Tyr3]octreotate by the combination of lysine and Gelofusine in rats , 2008, Nuklearmedizin.

[25]  R. Leahy,et al.  High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner. , 1998, Physics in medicine and biology.