Experimental investigation of slender circular RC columns strengthened with FRP composites

Abstract The relevant design code provisions for Fiber Reinforced Polymer (FRP) strengthened RC columns are restricted to the short RC columns strengthened with FRP jackets. These design provisions are thus strictly not applicable to those long RC columns where second-order/slenderness effect is substantial. In the present study, the effectiveness of hoop and longitudinal Carbon FRP (CFRP) wraps in reducing the lateral deflections and improving the strength of slender circular RC columns has been studied experimentally. A total of 12 small-scale circular RC columns of 150 mm diameter were cast in three groups, each group containing 4 columns of the same height. The columns of the first group belonged to short columns of 600 mm height, whereas the columns of second and third groups of 900 and 1200 mm heights respectively represented slender columns. Columns of each group had one control and 3 strengthened columns. The strengthened columns were prepared using three different strengthening schemes. In the first strengthening scheme, the columns were wrapped using a single layer of hoop CFRP sheet, whereas other strengthening schemes employed 2 and 4 longitudinal CFRP sheets in addition to one layer of hoop CFRP wrap. The columns were tested under monotonic compression with initial eccentricity of 25 mm. In general, CFRP-strengthening improves the strength and ductility of slender RC columns substantially. The test results indicate that the CFRP hoop wraps provide confinement to concrete and lateral support to the longitudinal fibers and thus increase the strength of the RC columns. In slender columns, the effect of longitudinal FRP fibers in carrying the load in post-yielding stage is more significant than hoop FRP fibers. The existing ACI expression of slenderness limit for RC columns was extended to propose a simple analytical equation for the slenderness limit of FRP-strengthened RC columns. The proposed expression for slenderness limit is valid for both RC and FRP-confined columns and matches well with the experimentally observed slenderness limit.

[1]  Carl T.F. Ross,et al.  Strength of materials and structures , 1992 .

[2]  Tarek H. Almusallam,et al.  Seismic Rehabilitation of Corner RC Beam-Column Joints Using CFRP Composites , 2010 .

[3]  Matthew B. Blaschko,et al.  Externally bonded FRP reinforcement for RC structures , 2001 .

[4]  Lin-Hai Han,et al.  Experimental behaviour of FRP-confined slender RC columns under eccentric loading , 2004 .

[5]  Nadeem A. Siddiqui,et al.  Reliability of shear-deficient RC beams strengthened with CFRP-strips , 2013 .

[6]  Lars Damkilde,et al.  Nordic Concrete Research , 1996 .

[7]  Nestore Galati,et al.  LARGE-SIZE REINFORCED CONCRETE COLUMNS STRENGTHENED WITH CARBON FRP: VALIDATION OF EXISTING DESIGN GUIDELINES , 2006 .

[8]  L. Lorenzis,et al.  Applicability of FRP confinement to strengthen concrete columns , 2004 .

[9]  Jin-Guang Teng,et al.  Theoretical model for slender FRP-confined circular RC columns , 2012 .

[10]  Amir Mirmiran,et al.  SLENDERNESS LIMIT FOR HYBRID FRP-CONCRETE COLUMNS , 2001 .

[11]  J. Pan,et al.  Experimental investigation of load carrying capacity of the slender reinforced concrete columns wrapped with FRP , 2007 .

[12]  Mark F. Green,et al.  COMPARISON OF CONFINEMENT MODELS FOR FIBER-REINFORCED POLYMER-WRAPPED CONCRETE , 2005 .

[13]  J G MacGregor DESIGN OF SLENDER CONCRETE COLUMNS - REVISITED , 1993 .

[14]  Z. Tao,et al.  Behaviour of fire-exposed concrete-filled steel tubular beam columns repaired with CFRP wraps , 2007 .

[15]  J. G. Teng,et al.  Slenderness Limit for Short FRP-Confined Circular RC Columns , 2012 .

[16]  T. Almusallam,et al.  Seismic Behavior of As-Built, ACI-Complying, and CFRP-Repaired Exterior RC Beam-Column Joints , 2011 .

[17]  John E. Breen,et al.  Design of Slender Concrete Columns , 1970 .

[18]  Jack P. Moehle,et al.  "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318-11) AND COMMENTARY" , 2011 .

[19]  R. Al-Mahaidi,et al.  Rational design analysis of stub columns fabricated using very high strength circular steel tubes , 2005 .

[20]  Stephanie L. Walkup,et al.  Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures (ACI 440.2R-02) , 2005 .

[21]  Luke Bisby,et al.  Axial-flexural interaction in circular FRP-confined reinforced concrete columns , 2010 .

[22]  Juraj Bilčík,et al.  Full-Scale Testing of CFRP-Strengthened Slender Reinforced Concrete Columns , 2013 .

[23]  R. Tepfers,et al.  Stability of round concrete columns confined by composite wrappings , 2007 .

[24]  T. Almusallam,et al.  Seismic Response of FRP-Upgraded Exterior RC Beam-Column Joints , 2010 .

[25]  Tarek H. Almusallam,et al.  Effect of blast loading on CFRP-Retrofitted RC columns - a numerical study , 2011 .

[26]  Nadeem A. Siddiqui,et al.  Experimental investigation of RC beams strengthened with externally bonded FRP composites , 2010 .

[27]  Luke Bisby,et al.  Slenderness Effects on Circular CFRP Confined Reinforced Concrete Columns , 2010 .