Investigation of indoor air quality at residential homes in Hong Kong - Case study

Abstract Indoor air quality (IAQ) has been a matter of public concern in Hong Kong. Recently, the Hong Kong Government has recognized the potential risk and problems related to indoor air pollution, and it is striving to establish IAQ objectives for different types of indoor environments. This study attempts to provide more information about the present IAQ of local resident flats. Air pollutants measured in this study included carbon dioxide (CO2), respirable suspended particulate matter (PM10), formaldehyde (HCHO), volatile organic compounds (VOCs) and airborne bacteria. The results of this study indicate that the 8-h average concentrations of CO2 and PM10 in the domestic kitchens investigated were 14% and 67% higher than those measured in the living rooms. The indoor air pollution caused by PM10 was more serious in domestic kitchens than in living rooms as almost all of the kitchens investigated had higher indoor levels of PM10. The majority of the domestic living rooms and kitchens studied had average concentrations of airborne bacteria higher than 500 CFU/m3. The mean total bacteria count recorded in kitchens was greater than that obtained in living rooms by 23%. In homes where occupants smoke, the negative impact of benzene, toluene and m,p-xylene on the IAQ was greatly enhanced. The use of liquefied petroleum gas (LPG) stove has more significant impact on indoor VOCs than the use of cooking stoves with natural gas as cooking fuel.

[1]  S C Lee,et al.  Indoor air quality at nine shopping malls in Hong Kong. , 2001, The Science of the total environment.

[2]  Roger Perry,et al.  Indoor air quality in homes, offices and restaurants in Korean urban areas—indoor/outdoor relationships , 1997 .

[3]  W. Bouhamra Determination of volatile organic compounds in indoor and ambient air of residences in Kuwait , 1997 .

[4]  Jia‐Ming Lin,et al.  Formaldehyde in conventional homes in Taiwan , 1993 .

[5]  Shuncheng Lee,et al.  Indoor and outdoor air quality investigation at 14 public places in Hong Kong , 1999 .

[6]  D. Dockery,et al.  Long-term measurements of respirable sulfates and particles inside and outside homes , 1981 .

[7]  R. Perry,et al.  Vehicle Emissions and Effects on Air Quality: Indoors and Outdoors , 1994 .

[8]  M J Abramson,et al.  Increased risk of allergy in children due to formaldehyde exposure in homes , 1999, Allergy.

[9]  Bruce A. Tomkins,et al.  The chemistry of environmental tobacco smoke , 1992 .

[10]  D Mark,et al.  Indoor / outdoor relationships of particulate matter in domestic homes with roadside, urban and rural locations , 2000 .

[11]  Russell W. Wiener,et al.  A study of characterize indoor particles in three non-smoking homes , 1991 .

[12]  D. Kogelschatz,et al.  Particulate matter less than 10 μm (PM10) and fine particles less than 2.5 μm (PM2.5): relationships between indoor, outdoor and personal concentrations , 1997 .

[13]  S C Lee,et al.  Indoor and outdoor air quality investigation at schools in Hong Kong. , 2000, Chemosphere.

[14]  S. Lee,et al.  Indoor and outdoor air quality investigation at six residential buildings in Hong Kong , 1999 .

[15]  S C Lee,et al.  Indoor air quality at restaurants with different styles of cooking in metropolitan Hong Kong. , 2001, The Science of the total environment.

[16]  Risto Kostiainen,et al.  Volatile organic compounds in the indoor air of normal and sick houses , 1995 .

[17]  P. Vasconcellos,et al.  Characterization of indoor air quality in the cities of sao paulo and rio de janeiro, Brazil. , 1995, Environmental science & technology.

[18]  L. Chan,et al.  A study of bus commuter and pedestrian exposure to traffic air pollution in Hong Kong , 1993 .

[19]  Dennis Y.C. Leung,et al.  STREET-LEVEL CONCENTRATIONS OF NITROGEN DIOXIDE AND SUSPENDED PARTICULATE MATTER IN HONG KONG , 1998 .

[20]  L. Wallace,et al.  Indoor particles: a review. , 1996, Journal of the Air & Waste Management Association.

[21]  M. Garrett,et al.  Formaldehyde in Australian Homes; Levels and Sources , 1997 .

[22]  John Burnett,et al.  Influence of Different Indoor Activities on the Indoor Particulate Levels in Residential Buildings , 1998 .

[23]  Rufus Edwards,et al.  VOC concentrations measured in personal samples and residential indoor, outdoor and workplace microenvironments in EXPOLIS-Helsinki, Finland , 2001 .

[24]  C. Chan,et al.  Human exposure to respirable suspended particulate and airborne lead in different roadside microenvironments. , 2000, Chemosphere.

[25]  Ibrahim M. Banat,et al.  Residential indoor airborne microbial populations in the United Arab Emirates , 1997 .