Embedded piezoelectrics for sensing and energy harvesting in total knee replacement units

The knee replacement is the second most common orthopedic surgical intervention in the United States, but currently only 1 in 5 knee replacement patients are satisfied with their level of pain reduction one year after surgery. It is imperative to make the process of knee replacement surgery more objective by developing a data driven approach to ligamentous balance, which increases implant life. In this work, piezoelectric materials are considered for both sensing and energy harvesting applications in total knee replacement implants. This work aims to embed piezoelectric material in the polyethylene bearing of a knee replacement unit to act as self-powered sensors that will aid in the alignment and balance of the knee replacement by providing intraoperative feedback to the surgeon. Postoperatively, the piezoelectric sensors can monitor the structural health of the implant in order to perceive potential problems before they become bothersome to the patient. Specifically, this work will present on the use of finite element modeling coupled with uniaxial compression testing to prove that piezoelectric stacks can be utilized to harvest sufficient energy to power sensors needed for this application.

[1]  Richard D Komistek,et al.  Correlation of compartment pressure data from an intraoperative sensing device with postoperative fluoroscopic kinematic results in TKA patients. , 2005, Journal of biomechanics.

[2]  C. Rimnac,et al.  Cyclic steady state stress-strain behavior of UHMW polyethylene. , 2000, Biomaterials.

[3]  K. R. Kaufman,et al.  Physiological prediction of muscle forces—I. Theoretical formulation , 1991, Neuroscience.

[4]  J B Morrison,et al.  The mechanics of the knee joint in relation to normal walking. , 1970, Journal of biomechanics.

[5]  S. E. Irby,et al.  Instrumented implant for measuring tibiofemoral forces. , 1996, Journal of biomechanics.

[6]  Benjamin J Fregly,et al.  Knee joint forces: prediction, measurement, and significance , 2012, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[7]  D. D’Lima,et al.  e-Knee: Evolution of the Electronic Knee Prosthesis Telemetry Technology Development , 2001, The Journal of bone and joint surgery. American volume.

[8]  Richard W. Bohannon,et al.  Number of Pedometer-Assessed Steps Taken Per Day by Adults: A Descriptive Meta-Analysis , 2007, Physical Therapy.

[9]  R. Michael Meneghini,et al.  Development of Biomechanical Knee Force Model for Evaluation of Piezoelectric Sensors for In-Vivo Monitoring , 2014 .

[10]  Benjamin J Fregly,et al.  Implantable sensor technology: measuring bone and joint biomechanics of daily life in vivo , 2013, Arthritis Research & Therapy.

[11]  Ieee Standards Board IEEE Standard on Piezoelectricity , 1996 .

[12]  A. Edidin,et al.  Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty. , 1999, Biomaterials.

[13]  Harrington Ij,et al.  A bioengineering analysis of force actions at the knee in normal and pathological gait. , 1976 .

[14]  Christopher Townsend,et al.  A multiaxial force-sensing implantable tibial prosthesis. , 2006, Journal of biomechanics.

[15]  Shantanu Patil,et al.  In vivo knee moments and shear after total knee arthroplasty. , 2007, Journal of biomechanics.

[16]  Jan M. Rabaey,et al.  Improving power output for vibration-based energy scavengers , 2005, IEEE Pervasive Computing.

[17]  Ayman Habib,et al.  OpenSim: Open-Source Software to Create and Analyze Dynamic Simulations of Movement , 2007, IEEE Transactions on Biomedical Engineering.

[18]  J. P. Paul Approaches to design - Force actions transmitted by joints in the human body , 1976, Proceedings of the Royal Society of London. Series B. Biological Sciences.