Measurements After Image Post-processing Are More Precise in the Morphometric Assessment of Thoracic Aortic Aneurysms: An Intermodal and Intra-observer Evaluation.

OBJECTIVES Precise pre-procedural anatomical analysis of aneurysmal anatomy is essential for successful thoracic endovascular aortic repair (TEVAR). Since surgeons and radiologists have to perform multiple measurements in the same patient, high intra-observer reliability of any imaging method is mandatory. Commercially available three dimensional (3D) post-processing techniques are expected to be superior to conventional two dimensional multiplanar reconstructions (MPRs) derived from computed tomography angiograms (CTAs). However, few data exist to support this view. This study aims to evaluate the intermodal and intra-observer differences using 3D software (3surgery) in descending thoracic aortic aneurysms (dTAAs). METHODS Pre-operative CTAs (performed between 2004 and 2010) of 30 dTAAs (mean maximum diameter 61.4 ± 13 mm) were assessed by three independent investigators with different experience in the measurement of aortic pathologies. Intra-observer reliability and intermodal differences (3D vs. 2D) were investigated using pre-specified measurement points (distances of total length, maximum diameter, proximal and distal landing zones). Statistical analyses were performed using the Bland-Altman method and a mixed regression model. RESULTS Intermodal comparison showed that 2D measurements significantly underestimate the measured distances (maximum diameter 3.7 mm [95% CI -5.3 to -2.1] and landing zone maximum 1.4 mm [95% CI -2.0 to -0.2] shorter with 2D, p < .05). In almost all 3D measurements, all investigators showed lower variability comparing the intra-observer differences, most notably in the measuring point total length (reduction of the SD up to 7.9 mm). CONCLUSIONS These data show that both techniques led to significant measurement disparity. This occurs especially at the point of indication (maximum diameter) and the total length of the aneurysm (important for correct stent graft selection). But overall the variability is reduced with the 3D technique, which also tends to measure greater distances. The use of post-processing software therefore leads to more precise device selection for TEVAR in TAA.

[1]  Jean Marzelle,et al.  Factors favoring stent-graft collapse after thoracic endovascular aortic repair. , 2010, The Journal of thoracic and cardiovascular surgery.

[2]  S. Money,et al.  Influence of endograft oversizing on device migration, endoleak, aneurysm shrinkage, and aortic neck dilation: results from the Zenith Multicenter Trial. , 2004, Journal of vascular surgery.

[3]  F. Rengier,et al.  Reliability of semiautomatic centerline analysis versus manual aortic measurement techniques for TEVAR among non-experts. , 2011, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[4]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[5]  Joel Dunning,et al.  Endovascular aortic repair versus open surgical repair for descending thoracic aortic disease a systematic review and meta-analysis of comparative studies. , 2010, Journal of the American College of Cardiology.

[6]  R Bender,et al.  [Comparing methods of measurement]. , 2007, Deutsche medizinische Wochenschrift.

[7]  N. Rich,et al.  What imaging studies are necessary for abdominal aortic endograft sizing? A prospective blinded study using conventional computed tomography, aortography, and three-dimensional computed tomography. , 2005, Journal of vascular surgery.

[8]  J. Bartoli,et al.  Incidence and determinants of spinal cord ischaemia in stent-graft repair of the thoracic aorta. , 2008, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[9]  Satish C. Muluk,et al.  Two-Dimensional versus Three-Dimensional CT Scan for Aortic Measurement , 2003, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[10]  Fabian Rengier,et al.  Heartbeat-related distension and displacement of the thoracic aorta in healthy volunteers. , 2012, European journal of radiology.

[11]  S. Stavropoulos,et al.  Imaging techniques for detection and management of endoleaks after endovascular aortic aneurysm repair. , 2007, Radiology.

[12]  J. Lewin,et al.  Assessment of Automatic Vessel Tracking Techniques in Preoperative Planning of Transluminal Aortic Stent Graft Implantation , 2004, Journal of computer assisted tomography.

[13]  F. Rengier,et al.  Accuracy and variability of semiautomatic centerline analysis versus manual aortic measurement techniques for TEVAR. , 2013, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[14]  H. Kauczor,et al.  Centerline analysis of aortic CT angiographic examinations: benefits and limitations. , 2009, AJR. American journal of roentgenology.

[15]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[16]  M. Czerny,et al.  Contemporary spinal cord protection during thoracic and thoracoabdominal aortic surgery and endovascular aortic repair: a position paper of the vascular domain of the European Association for Cardio-Thoracic Surgery†. , 2015, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[17]  N. Rudarakanchana,et al.  Variation in maximum diameter measurements of descending thoracic aortic aneurysms using unformatted planes versus images corrected to aortic centerline. , 2014, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[18]  D. Altman,et al.  Measuring agreement in method comparison studies , 1999, Statistical methods in medical research.

[19]  S. Schulte,et al.  Two-dimensional versus three-dimensional CT angiography in analysis of anatomical suitability for stentgraft repair of abdominal aortic aneurysms , 2011, Acta radiologica.