An Adaptive Kalman Filter for ECG Signal Enhancement

The ongoing trend of ECG monitoring techniques to become more ambulatory and less obtrusive generally comes at the expense of decreased signal quality. To enhance this quality, consecutive ECG complexes can be averaged triggered on the heartbeat, exploiting the quasi-periodicity of the ECG. However, this averaging constitutes a tradeoff between improvement of the SNR and loss of clinically relevant physiological signal dynamics. Using a Bayesian framework, in this paper, a sequential averaging filter is developed that, in essence, adaptively varies the number of complexes included in the averaging based on the characteristics of the ECG signal. The filter has the form of an adaptive Kalman filter. The adaptive estimation of the process and measurement noise covariances is performed by maximizing the Bayesian evidence function of the sequential ECG estimation and by exploiting the spatial correlation between several simultaneously recorded ECG signals, respectively. The noise covariance estimates thus obtained render the filter capable of ascribing more weight to newly arriving data when these data contain morphological variability, and of reducing this weight in cases of no morphological variability. The filter is evaluated by applying it to a variety of ECG signals. To gauge the relevance of the adaptive noise-covariance estimation, the performance of the filter is compared to that of a Kalman filter with fixed, (a posteriori) optimized noise covariance. This comparison demonstrates that, without using a priori knowledge on signal characteristics, the filter with adaptive noise estimation performs similar to the filter with optimized fixed noise covariance, favoring the adaptive filter in cases where no a priori information is available or where signal characteristics are expected to fluctuate.

[1]  E. Hon,et al.  Instrumentation of fetal heart rate and fetal electrocardiography. II. A vaginal electrode. , 1963, American journal of obstetrics and gynecology.

[2]  G Papakonstantinou,et al.  Detection of the P and T waves in an ECG. , 1989, Computers and biomedical research, an international journal.

[3]  M Macklin,et al.  Changes in the conduction of the fetal electrocardiogram to the maternal abdominal surface during gestation. , 1977, American journal of obstetrics and gynecology.

[4]  Henry L. Lew,et al.  Overview of artifact reduction and removal in evoked potential and event-related potential recordings. , 2004, Physical medicine and rehabilitation clinics of North America.

[5]  A. W. M. van den Enden,et al.  Discrete Time Signal Processing , 1989 .

[6]  T. Başar,et al.  A New Approach to Linear Filtering and Prediction Problems , 2001 .

[7]  R Vullings,et al.  Dynamic segmentation and linear prediction for maternal ECG removal in antenatal abdominal recordings , 2009, Physiological measurement.

[8]  William H. Press,et al.  Numerical recipes in C. The art of scientific computing , 1987 .

[9]  P. Macfarlane,et al.  Recommendations for standardization and specifications in automated electrocardiography: bandwidth and digital signal processing. A report for health professionals by an ad hoc writing group of the Committee on Electrocardiography and Cardiac Electrophysiology of the Council on Clinical Cardiology, , 1990, Circulation.

[10]  J. E. Glynn,et al.  Numerical Recipes: The Art of Scientific Computing , 1989 .

[11]  S. Abboud,et al.  Spectral analysis of the fetal electrocardiogram. , 1989, Computers in biology and medicine.

[12]  Jeffrey M. Hausdorff,et al.  Physionet: Components of a New Research Resource for Complex Physiologic Signals". Circu-lation Vol , 2000 .

[13]  Wei Chen,et al.  A design of power supply for neonatal monitoring with wearable sensors , 2009, J. Ambient Intell. Smart Environ..

[14]  Christian Jutten,et al.  A Nonlinear Bayesian Filtering Framework for ECG Denoising , 2007, IEEE Transactions on Biomedical Engineering.

[15]  Yaakov Bar-Shalom,et al.  Estimation and Tracking: Principles, Techniques, and Software , 1993 .

[16]  A. Gruetzmann,et al.  Novel dry electrodes for ECG monitoring , 2007, Physiological measurement.

[17]  E. Frank An Accurate, Clinically Practical System For Spatial Vectorcardiography , 1956, Circulation.

[18]  G. Wittum,et al.  Adaptive filtering , 1997 .

[19]  J H van Bemmel,et al.  Detection procedure to represent the foetal heart rate and electrocardiogram. , 1966, IEEE transactions on bio-medical engineering.

[20]  Mahesan Niranjan,et al.  Hierarchical Bayesian-Kalman models for regularisation and ARD in sequential learning , 1997 .

[21]  M Oehler,et al.  A multichannel portable ECG system with capacitive sensors , 2008, Physiological measurement.

[22]  K. Greene,et al.  Changes in the ST waveform of the fetal lamb electrocardiogram with hypoxemia. , 1982, American journal of obstetrics and gynecology.

[23]  Kang-Ming Chang,et al.  Portable obstructive sleep apnea screening system using overnight ECG and a PDA-based wireless transmission system. , 2009, Telemedicine journal and e-health : the official journal of the American Telemedicine Association.