Development of an Ultrasonic Airflow Measurement Device for Ducted Air

In this study, an in-duct ultrasonic airflow measurement device has been designed, developed and tested. The airflow measurement results for a small range of airflow velocities and temperatures show that the accuracy was better than 3.5% root mean square (RMS) when it was tested within a round or square duct compared to the in-line Venturi tube airflow meter used for reference. This proof of concept device has provided evidence that with further development it could be a low-cost alternative to pressure differential devices such as the orifice plate airflow meter for monitoring energy efficiency performance and reliability of ventilation systems. The design uses a number of techniques and design choices to provide solutions to lower the implementation cost of the device compared to traditional airflow meters. The design choices that were found to work well are the single sided transducer arrangement for a “V” shaped reflective path and the use of square wave transmitter pulses ending with the necessary 180° phase changed pulse train to suppress transducer ringing. The device is also designed so that it does not have to rely on high-speed analogue to digital converters (ADC) and intensive digital signal processing, so could be implemented using voltage comparators and low-cost microcontrollers.

[1]  G. De Cicco,et al.  A microprocessor based, three axes, ultrasonic anemometer , 1985 .

[2]  Shengwei Wang,et al.  A model-based online fault detection and diagnosis strategy for centrifugal chiller systems , 2005 .

[3]  Takashi Katagiri,et al.  Real-time ultrasonic distance measurements for autonomous mobile robots using cross correlation by single-bit signal processing , 2009, 2009 IEEE International Conference on Robotics and Automation.

[4]  W. Guggenbuhl,et al.  Design and Construction of a Pulsed Ultrasonic Air Flowmeter , 1986, IEEE Transactions on Biomedical Engineering.

[5]  Maria Prudenziati,et al.  A 250 KHz Piezoelectric Transducer for Operation in Air: Application to Distance and Wind Velocity Measurements , 1982 .

[6]  Sabin Ionel,et al.  The development of CPLD-based ultrasonic flowmeter , 2007 .

[7]  Mike Scelzo,et al.  FUNDAMENTALS OF ULTRASONIC FLOW METERS , 2005 .

[8]  M. I. Bragg,et al.  Internally-nonprotruding one-port ultrasonic flow sensors for air and some other gases , 1994 .

[9]  Roger C. Baker,et al.  Flow Measurement Handbook: Industrial Designs, Operating Principles, Performance, and Applications , 2000 .

[10]  Dennis A. Bohn Environmental Effects on the Speed of Sound , 1988 .

[11]  Sekwang Park,et al.  Measurement range expansion of continuous wave ultrasonic anemometer , 2011 .

[12]  Robert A. Boie,et al.  Active damping of ultrasonic transducers for robotic applications , 1984, ICRA.

[13]  K. Witrisal,et al.  System identification method for Ultrasonic Intake Air Flow Meter for engine test bed applications , 2012, 2012 IEEE International Instrumentation and Measurement Technology Conference Proceedings.

[14]  Qiang Chen,et al.  Realization of a multipath ultrasonic gas flowmeter based on transit-time technique. , 2014, Ultrasonics.

[15]  Poong Hyun Seong,et al.  Estimation of the flow profile correction factor of a transit-time ultrasonic flow meter for the feedwater flow measurement in a nuclear power plant , 2005, IEEE Transactions on Nuclear Science.

[16]  Daniel Berckmans,et al.  Acoustical Ventilation Rate Sensor Concept for Naturally Ventilated Buildings , 2007 .

[17]  Canhui Cai,et al.  Accurate digital time-of-flight measurement using self-interference , 1993 .

[18]  Pablo M. Olmos Ultrasonic velocity meter to evaluate the behaviour of a solar chimney , 2004 .

[19]  Sekwang Park,et al.  Two-dimensional ultrasonic anemometer using the directivity angle of an ultrasonic sensor , 2008, Microelectron. J..

[20]  John P Bentley,et al.  Principles of measurement systems , 1983 .

[21]  Chih-Kung Lee,et al.  High-Precision Ultrasonic Ranging System Platform Based on Peak-Detected Self-Interference Technique , 2011, IEEE Transactions on Instrumentation and Measurement.

[22]  Yuebin Yu,et al.  A review of fault detection and diagnosis methodologies on air-handling units , 2014 .

[23]  Haorong Li,et al.  A virtual supply airflow rate meter for rooftop air-conditioning units , 2011 .

[24]  L. Lynnworth,et al.  Ultrasonic flowmeters: half-century progress report, 1955-2005. , 2006, Ultrasonics.

[25]  James W. Bowen FUNDAMENTALS OF ULTRASONIC FLOW METERS , 2001 .

[26]  P. Olmos Extending the accuracy of ultrasonic level meters , 2002 .