Combined Vascular and Orthopaedic Approach for a Pseudotumor Causing Deep Vein Thrombosis after Metal-on-Metal Hip Resurfacing Arthroplasty

Introduction. Metal-on-metal (MoM) hip resurfacings have been associated with a variety of complications resulting from adverse reaction to metal debris. Pseudotumors have rarely been reported to cause deep venous thrombosis (DVT). Study Design. A case report and a review of the literature. Case Presentation. A 75-year-old female who had left metal-on-metal hip resurfacing 6 years ago presented with left groin pain associated with unilateral lower limb edema and swelling. By duplex and MRI studies, our patient had an extensive soft tissue necrosis associated with a large pelvic mass causing extensive DVT of the lower limb secondary to mechanical compression of the left iliac vein. Results. Our case was initially treated for DVT followed by dual surgical approach. The pseudotumor was excised through a separate iliofemoral approach and revision of the hip implant was undertaken through a posterior approach in the same setting. An inferior vena cava (IVC) filter was inserted to minimise the perioperative risks of handling the iliac veins. Conclusion. A combined approach with vascular surgeons is required. Combined resection of the pseudotumor and revision of the metal bearing surfaces is essential, in order to achieve a good surgical outcome in this rare complication.

[1]  William F. Scully,et al.  Pseudotumor associated with metal-on-polyethylene total hip arthroplasty. , 2013, Orthopedics.

[2]  R. Gul,et al.  Inflammatory pseudotumor causing deep vein thrombosis after metal-on-metal hip resurfacing arthroplasty. , 2013, The Journal of arthroplasty.

[3]  M. Kurosaka,et al.  Leg edema due to a mass in the pelvis after a large-diameter metal-on-metal total hip arthroplasty. , 2013, The Journal of arthroplasty.

[4]  D. Parfitt,et al.  Common femoral vein thrombosis caused by a metal-on-metal hip arthroplasty-related pseudotumor. , 2012, The Journal of arthroplasty.

[5]  A. Leithner,et al.  Noninflammatory pseudotumor simulating venous thrombosis after metal-on-metal hip resurfacing. , 2011, Orthopedics.

[6]  J. Richardson,et al.  Birmingham hip resurfacing: the prevalence of failure. , 2010, The Journal of bone and joint surgery. British volume.

[7]  T J Joyce,et al.  Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: A consequence of excess wear. , 2010, The Journal of bone and joint surgery. British volume.

[8]  J. Holland,et al.  Pseudotumours associated with metal-on-metal hip resurfacing: 10-year Newcastle experience. , 2009, Acta orthopaedica Belgica.

[9]  D. Salter,et al.  Inflammatory pseudotumor associated with femoral nerve palsy following metal-on-metal resurfacing of the hip. A case report. , 2008, The Journal of bone and joint surgery. American volume.

[10]  D W Murray,et al.  Pseudotumours associated with metal-on-metal hip resurfacings. , 2008, The Journal of bone and joint surgery. British volume.

[11]  A. Gonzalez Della Valle,et al.  Extravascular compression of the femoral vein due to wear debris-induced iliopsoas bursitis: a rare cause of leg swelling after total hip arthroplasty. , 2007, The Journal of arthroplasty.

[12]  J. Fisher,et al.  Metal-on-metal bearings surfaces: Materials, manufacture, design, optimization, and alternatives , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[13]  K. Yonenobu,et al.  Huge pelvic mass secondary to wear debris causing ureteral obstruction. , 2005, The Journal of arthroplasty.

[14]  F. Shen,et al.  Biologic and tribologic considerations of alternative bearing surfaces. , 2004, Clinical orthopaedics and related research.