Multiresolution radial MRI to reduce IDLE time in pre-beam imaging on an MR-Linac (MR-RIDDLE)

Online adaptive MR-guided radiation therapy improves treatment quality at the expense of considerable longer treatment time. The treatment lengthening partially originates from the preparatory (pre-beam) MR imaging required to encode all the information needed for contour propagation, contour adaptation and replanning. MRI requires several minutes of scan time before the encoded information is converted to usable images, which results in long idle times before the first clinical tasks are performed. In this study we propose a novel imaging sequence, called MR-RIDDLE, that reduces the idle time and therefore speeds-up the workflow in online MR-guided radiation therapy. MR-RIDDLE enables multiresolution image reconstruction to commence during data acquisition where low resolution images are available within one minute, after which the data collection continuous for subsequent high-resolution image updates. We demonstrate that the low resolution images can be used to accurately propagate contours from the pre-treatment scan. For abdominothoracic tumours MR-RIDDLE inherently captures a motion-blurred representation of the mid-position, which we were able to deblur using a combination of an internal motion surrogate and auto-adaptive soft-gating filters. Our results demonstrate that MR-RIDDLE provides a robust, flexible and time-efficient strategy for pre-beam imaging, even for cases with large respiratory movements or baseline shifts within the acquisition. We anticipate that this novel concept of parallelising the MR imaging and the clinical tasks has the potential to considerably speed-up and streamline the online MR-guided radiation therapy workflow.

[1]  Hui Xue,et al.  Real‐time distortion correction of spiral and echo planar images using the gradient system impulse response function , 2016, Magnetic resonance in medicine.

[2]  C. Berg,et al.  Pancreatic tumor motion reduction by use of a custom abdominal corset , 2017 .

[3]  Walter F Block,et al.  Improved least squares MR image reconstruction using estimates of k‐Space data consistency , 2012, Magnetic resonance in medicine.

[4]  Jan J W Lagendijk,et al.  MRI/linac integration. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[5]  Yi Wang,et al.  Z intensity-weighted position self-respiratory gating method for free-breathing 3D cardiac CINE imaging. , 2011, Magnetic resonance imaging.

[6]  Cornel Zachiu,et al.  A framework for the correction of slow physiological drifts during MR-guided HIFU therapies: Proof of concept. , 2015, Medical physics.

[7]  Jan-Jakob Sonke,et al.  Mid-ventilation CT scan construction from four-dimensional respiration-correlated CT scans for radiotherapy planning of lung cancer patients. , 2006, International journal of radiation oncology, biology, physics.

[8]  B Denis de Senneville,et al.  An improved optical flow tracking technique for real-time MR-guided beam therapies in moving organs , 2015, Physics in medicine and biology.

[9]  Lars Kasper,et al.  Gradient system characterization by impulse response measurements with a dynamic field camera , 2013, Magnetic resonance in medicine.

[10]  M Glitzner,et al.  On-line 3D motion estimation using low resolution MRI , 2015, Physics in medicine and biology.

[11]  Bjorn Stemkens,et al.  Image-driven, model-based 3D abdominal motion estimation for MR-guided radiotherapy , 2016, Physics in medicine and biology.

[12]  Jeffrey A. Fessler,et al.  Nonuniform fast Fourier transforms using min-max interpolation , 2003, IEEE Trans. Signal Process..

[13]  M. Lustig,et al.  Free‐breathing pediatric MRI with nonrigid motion correction and acceleration , 2015, Journal of magnetic resonance imaging : JMRI.

[14]  B. Fallone,et al.  The rotating biplanar linac-magnetic resonance imaging system. , 2014, Seminars in radiation oncology.

[15]  Diego R. Martín,et al.  Multiresolution imaging using golden angle stack‐of‐stars and compressed sensing for dynamic MR urography , 2017, Journal of magnetic resonance imaging : JMRI.

[16]  Sasa Mutic,et al.  The ViewRay system: magnetic resonance-guided and controlled radiotherapy. , 2014, Seminars in radiation oncology.

[17]  M van Herk,et al.  Reconstruction of a time-averaged midposition CT scan for radiotherapy planning of lung cancer patients using deformable registrationa). , 2008, Medical physics.

[18]  Stuart Crozier,et al.  The Australian magnetic resonance imaging-linac program. , 2014, Seminars in radiation oncology.

[19]  G H Glover,et al.  Projection Reconstruction Techniques for Reduction of Motion Effects in MRI , 1992, Magnetic resonance in medicine.

[20]  Michael Lustig,et al.  Fast pediatric 3D free‐breathing abdominal dynamic contrast enhanced MRI with high spatiotemporal resolution , 2015, Journal of magnetic resonance imaging : JMRI.

[21]  J. Lagendijk,et al.  Kidney motion during free breathing and breath hold for MR-guided radiotherapy , 2013, Physics in medicine and biology.

[22]  Olaf Dössel,et al.  An Optimal Radial Profile Order Based on the Golden Ratio for Time-Resolved MRI , 2007, IEEE Transactions on Medical Imaging.

[23]  Manuel Guizar-Sicairos,et al.  Efficient subpixel image registration algorithms. , 2008, Optics letters.

[24]  Daniel K. Sodickson,et al.  Towards Routine Clinical Use of Radial Stack-of-Stars 3D Gradient-Echo Sequences for Reducing Motion Sensitivity , 2014 .

[25]  M Weiger,et al.  Motion‐adapted gating based on k‐space weighting for reduction of respiratory motion artifacts , 1997, Magnetic resonance in medicine.

[26]  P. Roemer,et al.  The NMR phased array , 1990, Magnetic resonance in medicine.

[27]  A N T J Kotte,et al.  First patients treated with a 1.5 T MRI-Linac: clinical proof of concept of a high-precision, high-field MRI guided radiotherapy treatment , 2017, Physics in medicine and biology.

[28]  W. Segars,et al.  4D XCAT phantom for multimodality imaging research. , 2010, Medical physics.

[29]  Jan J W Lagendijk,et al.  The magnetic resonance imaging-linac system. , 2014, Seminars in radiation oncology.

[30]  Jens Frahm,et al.  Correction of gradient‐induced phase errors in radial MRI , 2014, Magnetic resonance in medicine.

[31]  Michael Elad,et al.  ESPIRiT—an eigenvalue approach to autocalibrating parallel MRI: Where SENSE meets GRAPPA , 2014, Magnetic resonance in medicine.

[32]  Bjorn Stemkens,et al.  Optimizing 4-dimensional magnetic resonance imaging data sampling for respiratory motion analysis of pancreatic tumors. , 2015, International journal of radiation oncology, biology, physics.

[33]  Bjorn Stemkens,et al.  Effect of intra-fraction motion on the accumulated dose for free-breathing MR-guided stereotactic body radiation therapy of renal-cell carcinoma , 2017, Physics in medicine and biology.