Repeatability assessment of functional methods to estimate the glenohumeral joint centre

Functional methods can be used to determine the centre of rotation (CoR) of a ball-and-socket joint. The algorithms are used to locate rather the hip joint centre than the glenohumeral joint centre. The choice of the most suitable method depends especially on the intra- and inter-session repeatability of these methods. This paper aims at evaluating the intra- and inter-session repeatability of functional methods with which the glenohumeral joint rotation centre (GHRC) can be estimated in vivo. It also estimates the most suitable amplitude of functional movements. Five functional methods were tested: the algorithms of Gamage and Lasenby, bias compensation, symmetrical CoR estimation, normalisation method and helical axis. Ten subjects performed three cycles of three different movements (flexion–extension, abduction–adduction and circumduction). These movements were repeated three times with three different ranges of motion. Six subjects came back in order to evaluate the inter-session repeatability. For each test, the location of the GHRC was estimated by the five methods. The method to solve the functional problem and the range of functional movement affected the GHRC location. The results showed a good to excellent intra-session repeatability. The lowest repeatability error was found for the high amplitude whatever the methods used. The inter-session reliability was moderate. Finally, we suggest the use of functional methods with high amplitude movement in order to locate the GHRC with the best reliability.

[1]  A. Lundberg,et al.  A new method for estimating the axis of rotation and the center of rotation. , 1999, Journal of biomechanics.

[2]  Scott L Delp,et al.  Evaluation of a new algorithm to determine the hip joint center. , 2006, Journal of biomechanics.

[3]  Aurelio Cappozzo,et al.  Gait analysis methodology , 1984 .

[4]  P R Cavanagh,et al.  Accuracy of the functional method of hip joint center location: effects of limited motion and varied implementation. , 2001, Journal of biomechanics.

[5]  J. Fleiss,et al.  Intraclass correlations: uses in assessing rater reliability. , 1979, Psychological bulletin.

[6]  Sylvain Brochard,et al.  In vivo estimation of the glenohumeral joint centre by functional methods: accuracy and repeatability assessment. , 2010, Journal of biomechanics.

[7]  I Söderkvist,et al.  Determining the movements of the skeleton using well-configured markers. , 1993, Journal of biomechanics.

[8]  W. Taylor,et al.  A survey of formal methods for determining the centre of rotation of ball joints. , 2006, Journal of biomechanics.

[9]  H E Veeger,et al.  The position of the rotation center of the glenohumeral joint. , 2000, Journal of biomechanics.

[10]  Kjartan Halvorsen,et al.  Bias compensated least squares estimate of the center of rotation. , 2003, Journal of biomechanics.

[11]  Ahmet Erdemir,et al.  Assessment of the functional method of hip joint center location subject to reduced range of hip motion. , 2004, Journal of biomechanics.

[12]  Lillian Y. Chang,et al.  Constrained least-squares optimization for robust estimation of center of rotation. , 2007, Journal of biomechanics.

[13]  Lutz Dürselen,et al.  Accurate Determination of a Joint Rotation Center Based on the Minimal Amplitude Point Method , 2003, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[14]  Aurelio Cappozzo,et al.  An optimized protocol for hip joint centre determination using the functional method. , 2006, Journal of biomechanics.

[15]  Patrick Lacouture,et al.  Comparison of the SCoRE and HA methods for locating in vivo the glenohumeral joint centre. , 2007, Journal of biomechanics.

[16]  T Stammberger,et al.  Glenohumeral translation during active and passive elevation of the shoulder - a 3D open-MRI study. , 2000, Journal of biomechanics.

[17]  F. Veldpaus,et al.  Finite centroid and helical axis estimation from noisy landmark measurements in the study of human joint kinematics. , 1985, Journal of biomechanics.

[18]  Sahan Gamage,et al.  New least squares solutions for estimating the average centre of rotation and the axis of rotation. , 2002, Journal of biomechanics.

[19]  M. Schwartz,et al.  A new method for estimating joint parameters from motion data. , 2004, Journal of biomechanics.

[20]  P Lacouture,et al.  Effects of movement for estimating the hip joint centre. , 2007, Gait & posture.

[21]  Amy B. Zavatsky,et al.  Hip joint centre position estimation for clinical gait analysis , 2006 .

[22]  P M Rozing,et al.  The glenohumeral joint rotation centre in vivo. , 2000, Journal of biomechanics.

[23]  F C van der Helm,et al.  In vivo estimation of the glenohumeral joint rotation center from scapular bony landmarks by linear regression. , 1997, Journal of biomechanics.

[24]  Xudong Zhang,et al.  Determining finger segmental centers of rotation in flexion-extension based on surface marker measurement. , 2003, Journal of biomechanics.

[25]  Bryan Buchholz,et al.  ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion--Part II: shoulder, elbow, wrist and hand. , 2005, Journal of biomechanics.