Treatment of spinal fractures using Lubra plates

Summary The purpose of this retrospective study was to review the clinical use along with the shortand long-term outcome in patients treated with Lubra plates to stabilize spinal fracture and dislocations that were considered unstable at time of surgery according to the ‘three compartment theory’. The data that were collected included breed, age, gender, body weight of the patients, cause of injury, neurological grade (pre- and postoperative), radiographic findings, surgical treatment, and clinical and radiological outcome. Thirteen dogs and two cats were included with thoracic (1 case), thoracolumbar (3 cases), midlumbar (5 cases) and caudal lumbar (6 cases) vertebral fractures. For stabilization, the small-sized (3 cases), medium-sized (6 cases), and large-sized (6 cases) Lubra plates were used. The clinical outcome was excellent in 10/15 patients, functional in 2/15 and poor in 3/15 with a median follow-up period of nine years (range 2 months to 12 years). The fractures eventually stabilized by ventral spondylosis. No implant failure was seen, however demineralization of the spinous processes necessitated implant removal in one case. Our results suggest that Lubra plating is an appropriate technique for thoracolumbar and lumbar vertebral fractures as well as luxations in dogs and cats. The prognosis for neurological recovery was excellent when the animal had a neurological grade of 3 and was not paralyzed.

[1]  L. Guiot,et al.  Median sternotomy and ventral stabilisation using pins and polymethylmethacrylate for a comminuted T5 vertebral fracture in a Miniature Schnauzer , 2010, Veterinary and Comparative Orthopaedics and Traumatology.

[2]  B. Meij,et al.  Degenerative lumbosacral stenosis in dogs. , 2010, The Veterinary clinics of North America. Small animal practice.

[3]  C. Yardımcı,et al.  Stabilisation with dorsal and ventral fixation of a traumatic cervical instability in a dog. , 2009, Australian veterinary journal.

[4]  M. Doherr,et al.  Comparative study of vertebral fractures and luxations in dogs and cats , 2008, Veterinary and Comparative Orthopaedics and Traumatology.

[5]  J. Levine,et al.  Cervical spinal locking plate in combination with cortical ring allograft for a one level fusion in dogs with cervical spondylotic myelopathy. , 2008, Veterinary surgery : VS.

[6]  K. Gyselinck,et al.  Spinal fracture and luxation in dogs and cats , 2008, Veterinary and Comparative Orthopaedics and Traumatology.

[7]  A. Cross,et al.  Closed fluoroscopic-assisted spinal arch external skeletal fixation for the stabilization of vertebral column injuries in five dogs. , 2007, Veterinary surgery : VS.

[8]  O. Beşalti,et al.  Ventral fixation in atlantoaxial instability with axial fracture in a dog , 2006, Veterinary and Comparative Orthopaedics and Traumatology.

[9]  S. Wheeler,et al.  Small Animal Spinal Disorders: Diagnosis and Surgery , 2005 .

[10]  N. Sharp Chapter 13 – Trauma , 2005 .

[11]  P. Montavon,et al.  Tension band stabilization of fractures and luxations of the thoracolumbar vertebrae in dogs and cats: 38 cases (1993-2002). , 2004, Journal of the American Veterinary Medical Association.

[12]  N. Moens,et al.  Fracture of L7 vertebral articular facets and pedicles following dorsal laminectomy in a dog. , 2002, Journal of the American Veterinary Medical Association.

[13]  K. Bruecker Principles of vertebral fracture management. , 1996, Seminars in veterinary medicine and surgery.

[14]  P. Muir,et al.  Methylmethacrylate and bone screw repair of seventh lumbar vertebral fracture-luxations in dogs. , 1996, The Journal of small animal practice.

[15]  A. Shores Spinal trauma. Pathophysiology and management of traumatic spinal injuries. , 1992, The Veterinary clinics of North America. Small animal practice.

[16]  Bruecker Ka,et al.  Principles of spinal fracture management. , 1992 .

[17]  H. Seim,et al.  Principles of spinal fracture management. , 1992, Seminars in veterinary medicine and surgery.

[18]  N. Langrana,et al.  The biomechanical evaluation of a new fixation technique for spondylolysis using single and double tension-band wiring. , 1989, Bulletin of the Hospital for Joint Diseases Orthopaedic Institute.

[19]  W. R. Fox,et al.  Combined Kirschner-Ehmer device and dorsal spinal plate fixation technique for caudal lumbar vertebral fractures in dogs. , 1989, Journal of the American Veterinary Medical Association.

[20]  D. Lewis,et al.  Repair of sixth lumbar vertebral fracture-luxations, using transilial pins and plastic spinous-process plates in six dogs. , 1989, Journal of the American Veterinary Medical Association.

[21]  J. Wilson,et al.  Effect of application of polyvinilidine plates on the dorsal spinous processes of dogs. , 1987, Veterinary surgery : VS.

[22]  S. Withrow,et al.  The use of plastic plates for fixation of spinal fractures in the dog. , 1979, The Canadian veterinary journal = La revue veterinaire canadienne.

[23]  W. Lumb,et al.  Lumbar vertebral prosthesis in the dog. , 1972, American journal of veterinary research.

[24]  W. Lumb,et al.  Improved spinal plates and hypothermia as adjuncts to spinal surgery. , 1970, Journal of the American Veterinary Medical Association.