MRI-Only Based Radiotherapy Treatment Planning for the Rat Brain on a Small Animal Radiation Research Platform (SARRP)

Computed tomography (CT) is the standard imaging modality in radiation therapy treatment planning (RTP). However, magnetic resonance (MR) imaging provides superior soft tissue contrast, increasing the precision of target volume selection. We present MR-only based RTP for a rat brain on a small animal radiation research platform (SARRP) using probabilistic voxel classification with multiple MR sequences. Six rat heads were imaged, each with one CT and five MR sequences. The MR sequences were: T1-weighted, T2-weighted, zero-echo time (ZTE), and two ultra-short echo time sequences with 20 μs (UTE1) and 2 ms (UTE2) echo times. CT data were manually segmented into air, soft tissue, and bone to obtain the RTP reference. Bias field corrected MR images were automatically segmented into the same tissue classes using a fuzzy c-means segmentation algorithm with multiple images as input. Similarities between segmented CT and automatic segmented MR (ASMR) images were evaluated using Dice coefficient. Three ASMR images with high similarity index were used for further RTP. Three beam arrangements were investigated. Dose distributions were compared by analysing dose volume histograms. The highest Dice coefficients were obtained for the ZTE-UTE2 combination and for the T1-UTE1-T2 combination when ZTE was unavailable. Both combinations, along with UTE1-UTE2, often used to generate ASMR images, were used for further RTP. Using 1 beam, MR based RTP underestimated the dose to be delivered to the target (range: 1.4%-7.6%). When more complex beam configurations were used, the calculated dose using the ZTE-UTE2 combination was the most accurate, with 0.7% deviation from CT, compared to 0.8% for T1-UTE1-T2 and 1.7% for UTE1-UTE2. The presented MR-only based workflow for RTP on a SARRP enables both accurate organ delineation and dose calculations using multiple MR sequences. This method can be useful in longitudinal studies where CT’s cumulative radiation dose might contribute to the total dose.

[1]  S. Vandenberghe,et al.  MRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time Sequences , 2010, Journal of Nuclear Medicine.

[2]  Adam Johansson,et al.  Improved quality of computed tomography substitute derived from magnetic resonance (MR) data by incorporation of spatial information – potential application for MR-only radiotherapy and attenuation correction in positron emission tomography , 2013, Acta oncologica.

[3]  Edward E Graves,et al.  The importance of tissue segmentation for dose calculations for kilovoltage radiation therapy. , 2011, Medical physics.

[4]  Chunming Li,et al.  MRI Tissue Classification and Bias Field Estimation Based on Coherent Local Intensity Clustering: A Unified Energy Minimization Framework , 2009, IPMI.

[5]  J. Conway,et al.  CT simulation for radiotherapy treatment planning. , 2002, The British journal of radiology.

[6]  James C. Bezdek,et al.  Pattern Recognition with Fuzzy Objective Function Algorithms , 1981, Advanced Applications in Pattern Recognition.

[7]  Erik Tryggestad,et al.  Small animal radiotherapy research platforms , 2011, Physics in medicine and biology.

[8]  Mary Feng,et al.  Investigation of a method for generating synthetic CT models from MRI scans of the head and neck for radiation therapy , 2013, Physics in medicine and biology.

[9]  Arne Skretting,et al.  A simulation of MRI based dose calculations on the basis of radiotherapy planning CT images , 2008, Acta oncologica.

[10]  Frank Verhaegen,et al.  A review of treatment planning for precision image-guided photon beam pre-clinical animal radiation studies. , 2014, Zeitschrift fur medizinische Physik.

[11]  D. Jaffray,et al.  The influence of antiscatter grids on soft-tissue detectability in cone-beam computed tomography with flat-panel detectors. , 2004, Medical physics.

[12]  Frank Verhaegen,et al.  Development and validation of a treatment planning system for small animal radiotherapy: SmART-Plan. , 2013, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[13]  Simon R Cherry,et al.  In vivo molecular and genomic imaging: new challenges for imaging physics. , 2004, Physics in medicine and biology.

[14]  W. Miller,et al.  TLD assessment of mouse dosimetry during microCT imaging. , 2008, Medical physics.

[15]  Christian Vanhove,et al.  MRI-guided 3D conformal arc micro-irradiation of a F98 glioblastoma rat model using the Small Animal Radiation Research Platform (SARRP) , 2014, Journal of Neuro-Oncology.

[16]  Adam Johansson,et al.  CT substitute derived from MRI sequences with ultrashort echo time. , 2011, Medical physics.

[17]  D. Shukla,et al.  T2 weighted MRI in assessment of volume changes during radiotherapy of high grade gliomas. , 2005, Journal of cancer research and therapeutics.

[18]  T. Sørensen,et al.  A method of establishing group of equal amplitude in plant sociobiology based on similarity of species content and its application to analyses of the vegetation on Danish commons , 1948 .

[19]  A. Fiorentino,et al.  Clinical target volume definition for glioblastoma radiotherapy planning: magnetic resonance imaging and computed tomography , 2013, Clinical and Translational Oncology.

[20]  S. Figueroa,et al.  TLD assessment of mouse dosimetry during microCT imaging. , 2008, Medical physics.