Coordinate Transformation-Free Observer-Based Adaptive Estimation of Distorted Single-Phase Grid Voltage Signal

This paper studies the phase and frequency estimation problem of single-phase grid voltage signal in the presence of DC offset and harmonics. For this purpose, a novel parameterized linear model of the grid voltage signal is considered where the unknown frequency of the grid is considered as the parameter. Based on the developed model, a linear observer (Luenberger type) is proposed. Then using Lyapunov stability theory, an estimator of the unknown grid frequency is developed. In order to deal with the grid harmonics, multiple parallel observers are then proposed. The proposed technique is inspired by other Luenberger observers already proposed in the literature. Those techniques use coordinate transformation that requires real-time matrix inverse calculation. The proposed technique avoids real-time matrix inversion by using a novel state-space model of the grid voltage signal. In comparison to similar other techniques available in the literature, no coordinate transformation is required. This significantly reduces the computational complexity w.r.t. similar other techniques. Comparative experimental results are provided with respect to two other recently proposed nonlinear techniques to show the dynamic performance improvement. Experimental results demonstrate the suitability of the proposed technique.

[1]  Nishant Kumar,et al.  A Quadrature Oscillator-Based DT for Accurate Estimation of Fundamental Load Current for PV System in Distribution Network , 2019, IEEE Transactions on Industrial Informatics.

[2]  Vassilios G. Agelidis,et al.  Three-Phase PLL for Grid-Connected Power Converters Under Both Amplitude and Phase Unbalanced Conditions , 2019, IEEE Transactions on Industrial Electronics.

[3]  M. Karimi-Ghartemani,et al.  A Unifying Approach to Single-Phase Synchronous Reference Frame PLLs , 2013, IEEE Transactions on Power Electronics.

[4]  Hafiz Ahmed,et al.  Frequency-Locked Loop-Based Estimation of Single-Phase Grid Voltage Parameters , 2019, IEEE Transactions on Industrial Electronics.

[5]  Masoud Karimi-Ghartema,et al.  Enhanced Phase-Locked Loop Structures for Power and Energy Applications , 2014 .

[6]  Zhiyong Dai,et al.  Estimation of Single-Phase Grid Voltage Parameters With Zero Steady-State Error , 2016, IEEE Transactions on Power Electronics.

[7]  Nishant Kumar,et al.  Integration of Solar PV With Low-Voltage Weak Grid System: Using Maximize-M Kalman Filter and Self-Tuned P&O Algorithm , 2019, IEEE Transactions on Industrial Electronics.

[8]  Md. Shamim Reza,et al.  Open-Loop Approach for Robust Detection of Selective Harmonic in Single-Phase System , 2019, IEEE Transactions on Industrial Informatics.

[9]  Remus Teodorescu,et al.  A New Single-Phase PLL Structure Based on Second Order Generalized Integrator , 2006 .

[10]  Mohamed Benbouzid,et al.  Frequency Adaptive Parameter Estimation of Unbalanced and Distorted Power Grid , 2020, IEEE Access.

[11]  Patrice Wira,et al.  A novel robust PLL algorithm applied to the control of a shunt active power filter using a self tuning filter concept , 2018, 2018 IEEE International Conference on Industrial Technology (ICIT).

[12]  El Madjid Berkouk,et al.  A Pseudo Open Loop Synchronization technique for heavily distorted grid voltage , 2018 .

[13]  Leilei Guo,et al.  A Model Predictive Control Method for Grid-Connected Power Converters Without AC Voltage Sensors , 2021, IEEE Transactions on Industrial Electronics.

[14]  Christoph M. Hackl,et al.  A Unified Method for Online Detection of Phase Variables and Symmetrical Components of Unbalanced Three-Phase Systems with Harmonic Distortion , 2019, Energies.

[15]  Derek Abbott,et al.  Comparative Study of Discrete PI and PR Controls for Single-Phase UPS Inverter , 2020, IEEE Access.

[16]  Asier Ibeas,et al.  Robust Control of Grid-Tied Parallel Inverters Using Nonlinear Backstepping Approach , 2019, IEEE Access.

[17]  Vassilios G. Agelidis,et al.  Accurate Estimation of Single-Phase Grid Voltage Parameters Under Distorted Conditions , 2014, IEEE Transactions on Power Delivery.

[18]  V. Agelidis,et al.  Accurate Estimation of Single-Phase Grid Voltage Fundamental Amplitude and Frequency by Using a Frequency Adaptive Linear Kalman Filter , 2016, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[19]  Hafiz Ahmed,et al.  Fast Estimation of Phase and Frequency for Single-Phase Grid Signal , 2019, IEEE Transactions on Industrial Electronics.

[20]  Saad Mekhilef,et al.  Single-phase Hybrid Active Power Filter with Adaptive Notch Filter for Harmonic Current Estimation , 2011 .

[21]  Bijaya Ketan Panigrahi,et al.  Recursive Least Squares-Based Adaptive Parameter Estimation Scheme for Signal Transformation and Grid Synchronization , 2020, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[22]  M. Karimi-Ghartemani,et al.  Addressing DC Component in PLL and Notch Filter Algorithms , 2012, IEEE Transactions on Power Electronics.

[23]  Juan C. Vasquez,et al.  Performance improvement of shunt active power filter based on non-linear least-square approach , 2018, Electric Power Systems Research.

[24]  Josep M. Guerrero,et al.  An Improved Hybrid Prefiltered Open-Loop Algorithm for Three-Phase Grid Synchronization , 2021, IEEE Transactions on Industrial Electronics.

[25]  Kamel Kara,et al.  Enhanced structure of second-order generalized integrator frequency-locked loop suitable for DC-offset rejection in single-phase systems , 2019 .

[26]  M. Jaya Bharata Reddy,et al.  Sliding Mode Control of Single-Phase Grid-Connected Quasi-Z-Source Inverter , 2017, IEEE Access.

[27]  Doğan Çelik,et al.  Benchmarking simulation and theory of various PLLs produce orthogonal signals under abnormal electric grid conditions , 2018 .

[28]  Ali Bechouche,et al.  Grid Voltages Estimation for Three-Phase PWM Rectifiers Control Without AC Voltage Sensors , 2018, IEEE Transactions on Power Electronics.

[29]  A.E. Leon,et al.  Software Sensor-Based STATCOM Control Under Unbalanced Conditions , 2009, IEEE Transactions on Power Delivery.

[30]  Mohammad Pichan,et al.  A new simple structure PLL for both single and three phase applications , 2016 .

[31]  Zhiyong Dai,et al.  Adaptive Estimation of Three-Phase Grid Voltage Parameters Under Unbalanced Faults and Harmonic Disturbances , 2017, IEEE Transactions on Power Electronics.

[32]  Bowen Wang,et al.  Accurate and Fast Harmonic Detection Based on the Generalized Trigonometric Function Delayed Signal Cancellation , 2019, IEEE Access.

[33]  Mohamed Benbouzid,et al.  Demodulation type single‐phase PLL with DC offset rejection , 2020 .

[34]  Malabika Basu,et al.  Protection of Sensitive Loads Using Sliding Mode Controlled Three-Phase DVR With Adaptive Notch Filter , 2019, IEEE Transactions on Industrial Electronics.

[35]  Juan C. Vasquez,et al.  Adaptive CDSC-Based Open-Loop Synchronization Technique for Dynamic Response Enhancement of Active Power Filters , 2019, IEEE Access.

[36]  Yongchang Zhang,et al.  Grid-Voltage Sensorless Model Predictive Control of Three-Phase PWM Rectifier Under Unbalanced and Distorted Grid Voltages , 2020, IEEE Transactions on Power Electronics.

[37]  Milos Doroslovacki,et al.  Adaptive cascaded Delayed Signal Cancellation PLL for three-phase grid under unbalanced and distorted condition , 2020 .

[38]  Hafiz Ahmed,et al.  Modeling and Tuning of Circular Limit Cycle Oscillator FLL With Preloop Filter , 2019, IEEE Transactions on Industrial Electronics.