An observed correlation between flow and electrical properties of pharmaceutical blends

Abstract We study the relation between flow and electrical conductivity of multiple formulations of pharmaceutical powder blends. Ten formulations were tested, consisting of two excipient sets, two active preparations, and a variety of food-grade additives including magnesium stearate (MgSt), and ionic and conductive materials such as ascorbic acid, talc, sodium carbonate, colloidal silica and TiO2. Electrical impedance, flow index and dilation were independently measured for all of the blends, and a strong correlation was found between every pair of these three properties. The relation between flow and dilation has been observed before; we find for the first time that there is an exponential relationship between flow index or dilation and impedance. This indicates that cohesive powder behavior depends on powder electrical properties, raising the questions of whether additives such as MgSt affect friction and conductivity per se and what mechanism and phenomenon links cohesion and conductivity.

[1]  A. Hickey,et al.  Flow properties of selected pharmaceutical powders from a vibrating spatula , 1994 .

[2]  S. Aly The resistance to compression index as a parameter to evaluate the efficacy of lubricants in pharmaceutical tabletting , 2006 .

[3]  J. Dodds,et al.  The effects of ambient temperature on the compaction of pharmaceutical powders , 2006 .

[4]  R L Carr,et al.  EVALUATING FLOW PROPERTIES OF SOLIDS , 1965 .

[5]  G. Rowley,et al.  Effect of contamination of pharmaceutical equipment on powder triboelectrification. , 2000, International journal of pharmaceutics.

[6]  T. Shinbrot,et al.  Triboelectrification and razorbacks: geophysical patterns produced in dry grains. , 2006, Physical review letters.

[7]  M. Perales,et al.  Evaluation of an adequate method of estimating flowability according to powder characteristics , 1994 .

[8]  Troy Shinbrot,et al.  Spontaneous separation of charged grains. , 2007, Physical review letters.

[9]  D. Apelian,et al.  Modeling of Conductivity Versus Density Behavior in Green-State Powder Metallurgy Compacts , 2002 .

[10]  G. Enstad,et al.  Flowability Measurements of Pharmaceutical Powder Mixtures with Poor Flow Using Five Different Techniques , 2004, Drug development and industrial pharmacy.

[11]  S. Hoag,et al.  Design and validation of an annular shear cell for pharmaceutical powder testing. , 2001, Journal of pharmaceutical sciences.

[12]  Kaori Fukunaga,et al.  Space charge behavior in an antistatic polymer including polymer solid electrolyte , 1996 .

[13]  Bruno C. Hancock,et al.  Development of a robust procedure for assessing powder flow using a commercial avalanche testing instrument. , 2004, Journal of pharmaceutical and biomedical analysis.

[14]  K. Morris,et al.  Triboelectrification of pharmaceutically relevant powders during low-shear tumble blending , 2006 .

[15]  G Rowley,et al.  Quantifying electrostatic interactions in pharmaceutical solid systems. , 2001, International journal of pharmaceutics.

[16]  Mojtaba Ghadiri,et al.  Measurement of Charge Transfer due to Single Particle Impact , 2006 .

[17]  M. Viana,et al.  Powder Functionality Test: A Methodology for Rheological and Mechanical Characterization , 2005, Pharmaceutical development and technology.

[18]  Bruno C. Hancock,et al.  Modelling the mechanical behaviour of pharmaceutical powders during compaction , 2005 .

[19]  Fernando J. Muzzio,et al.  Flow ‐ induced dilation of cohesive granular materials , 2006 .

[20]  F. Podczeck,et al.  The influence of particle size and relative humidity of air on the shear properties of pharmaceutical powders , 2004 .

[21]  Pierre Tchoreloff,et al.  Modelling the compaction behaviour of powders: application to pharmaceutical powders , 2002 .

[22]  Bruno C. Hancock,et al.  Improving the prediction of exceptionally poor tableting performance: an investigation into Hiestand's "special case". , 2004, Journal of pharmaceutical sciences.

[23]  B. Leclerc,et al.  Rheological characterization of pharmaceutical powders using tap testing, shear cell and mercury porosimeter. , 1999, International journal of pharmaceutics.

[24]  Ratikanta Sahoo,et al.  Degradation behaviour of weathered coal during handling for the COREX process of iron making , 2005 .