Self-calibrated algorithms for diffuse optical tomography and bioluminescence tomography using relative transmission images

Reconstruction algorithms for diffuse optical tomography (DOT) and bioluminescence tomography (BLT) have been developed based on diffusion theory. The algorithms numerically solve the diffusion equation using the finite element method. The direct measurements of the uncalibrated light fluence rates by a camera are used for the reconstructions. The DOT is self-calibrated by using all possible pairs of transmission images obtained with external sources along with the relative values of the simulated data and the calculated Jacobian. The reconstruction is done in the relative domain with the cancelation of any geometrical or optical factors. The transmission measurements for the DOT are used for calibrating the bioluminescence measurements at each wavelength and then a normalized system of equations is built up which is self-calibrated for the BLT. The algorithms have been applied to a three dimensional model of the mouse (MOBY) segmented into tissue regions which are assumed to have uniform optical properties. The DOT uses the direct method for calculating the Jacobian. The BLT uses a reduced space of eigenvectors of the Green's function with iterative shrinking of the permissible source region. The reconstruction results of the DOT and BLT algorithms show good agreement with the actual values when using either absolute or relative data. Even a small calibration error causes significant degradation of the reconstructions based on absolute data.

[1]  Vasilis Ntziachristos,et al.  Looking and listening to light: the evolution of whole-body photonic imaging , 2005, Nature Biotechnology.

[2]  Arye Nehorai,et al.  Image reconstruction for diffuse optical tomography using sparsity regularization and expectation-maximization algorithm. , 2007, Optics express.

[3]  Alexander D Klose,et al.  Transport-theory-based stochastic image reconstruction of bioluminescent sources. , 2007, Journal of the Optical Society of America. A, Optics, image science, and vision.

[4]  M. Schweiger,et al.  The finite element method for the propagation of light in scattering media: boundary and source conditions. , 1995, Medical physics.

[5]  David A. Boas,et al.  Tetrahedral mesh generation from volumetric binary and grayscale images , 2009, 2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[6]  R. Leahy,et al.  Hyperspectral and multispectral bioluminescence optical tomography for small animal imaging , 2005, Physics in medicine and biology.

[7]  P. Peltié,et al.  Noncontact fluorescence diffuse optical tomography of heterogeneous media. , 2007, Applied optics.

[8]  Jie Tian,et al.  A multi-phase level set framework for source reconstruction in bioluminescence tomography , 2010, J. Comput. Phys..

[9]  Jean-Marc Dinten,et al.  Optical calibration protocol for an x-ray and optical multimodality tomography system dedicated to small-animal examination. , 2009, Applied optics.

[10]  Michael S. Patterson,et al.  Bioluminescence tomography using eigenvectors expansion and iterative solution for the optimized permissible source region , 2011, Biomedical optics express.

[11]  Yasuyoshi Watanabe,et al.  [Molecular imaging for drug development]. , 2007, Brain and nerve = Shinkei kenkyu no shinpo.

[12]  Jie Tian,et al.  Truncated Total Least Squares Method with a Practical Truncation Parameter Choice Scheme for Bioluminescence Tomography Inverse Problem , 2010, Int. J. Biomed. Imaging.

[13]  Richard M. Leahy,et al.  A method for atlas-based volumetric registration with surface constraints for optical bioluminescence tomography in small animal imaging , 2007, SPIE Medical Imaging.

[14]  B. Rice,et al.  Three-dimensional reconstruction of in vivo bioluminescent sources based on multispectral imaging. , 2007, Journal of biomedical optics.

[15]  Eric C Frey,et al.  Development of a 4-D digital mouse phantom for molecular imaging research. , 2004, Molecular imaging and biology : MIB : the official publication of the Academy of Molecular Imaging.

[16]  H. Jiang,et al.  Frequency-domain fluorescent diffusion tomography: a finite-element-based algorithm and simulations. , 1998, Applied optics.

[17]  Xiaochao Qu,et al.  3D reconstruction of light flux distribution on arbitrary surfaces from 2D multi-photographic images. , 2010, Optics express.

[18]  R. Leahy,et al.  Fast iterative image reconstruction methods for fully 3D multispectral bioluminescence tomography , 2008, Physics in medicine and biology.

[19]  E. Richer,et al.  Iterative reconstruction method for light emitting sources based on the diffusion equation. , 2005, Medical physics.

[20]  M. Patterson,et al.  Algorithms for bioluminescence tomography incorporating anatomical information and reconstruction of tissue optical properties , 2010, Biomedical optics express.

[21]  B. Pogue,et al.  Spectrally resolved bioluminescence optical tomography. , 2006, Optics letters.

[22]  A. Adibi,et al.  Optimal sparse solution for fluorescent diffuse optical tomography: theory and phantom experimental results. , 2007, Applied optics.

[23]  A. Rehemtulla,et al.  Molecular Imaging , 2009, Methods in Molecular Biology.

[24]  Richard Coppola,et al.  Prefrontal Cortex Modulation during Anticipation of Working Memory Demands as Revealed by Magnetoencephalography , 2010, Int. J. Biomed. Imaging.

[25]  Julius Pekar,et al.  MULTISPECTRAL BIOLUMINESCENCE TOMOGRAPHY WITH X-RAY CT SPATIAL PRIORS , 2011 .

[26]  T. Chan,et al.  Source reconstruction for spectrally-resolved bioluminescence tomography with sparse a priori information. , 2009, Optics express.

[27]  Jie Tian,et al.  Multimodality Molecular Imaging , 2008, IEEE Engineering in Medicine and Biology Magazine.

[28]  Geoffrey McLennan,et al.  Practical reconstruction method for bioluminescence tomography. , 2005, Optics express.

[29]  Alwin Kienle,et al.  250 years Lambert surface: does it really exist? , 2011, Optics express.

[30]  Brian W. Pogue,et al.  Modeling and image reconstruction in spectrally resolved bioluminescence tomography , 2007, SPIE BiOS.

[31]  S. Arridge Optical tomography in medical imaging , 1999 .

[32]  M. Schweiger,et al.  A finite element approach for modeling photon transport in tissue. , 1993, Medical physics.

[33]  Hamid Dehghani,et al.  Near infrared optical tomography using NIRFAST: Algorithm for numerical model and image reconstruction. , 2009, Communications in numerical methods in engineering.

[34]  Michael S. Patterson,et al.  Improved bioluminescence and fluorescence reconstruction algorithms using diffuse optical tomography, normalized data, and optimized selection of the permissible source region , 2010, Biomedical optics express.

[35]  Jie Tian,et al.  An optimal permissible source region strategy for multispectral bioluminescence tomography. , 2008, Optics express.

[36]  M S Patterson,et al.  Quantification of bioluminescence images of point source objects using diffusion theory models , 2006, Physics in medicine and biology.

[37]  Hua-bei Jiang,et al.  Three-dimensional bioluminescence tomography with model-based reconstruction. , 2004, Optics express.

[38]  A. Chatziioannou,et al.  Tomographic bioluminescence imaging by use of a combined optical-PET (OPET) system: a computer simulation feasibility study , 2005, Physics in medicine and biology.