Radiation impedance of collapsed capacitive micromachined ultrasonic transducers

The radiation impedance of a capacitive micromachined ultrasonic transducer (CMUT) array is a critical parameter to achieve high performance. In this paper, we present a calculation of the radiation impedance of collapsed, clamped, circular CMUTs both analytically and using finite element method (FEM) simulations. First, we model the radiation impedance of a single collapsed CMUT cell analytically by expressing its velocity profile as a linear combination of special functions for which the generated pressures are known. For an array of collapsed CMUT cells, the mutual impedance between the cells is also taken into account. The radiation impedances for arrays of 7, 19, 37, and 61 circular collapsed CMUT cells for different contact radii are calculated both analytically and by FEM simulations. The radiation resistance of an array reaches a plateau and maintains this level for a wide frequency range. The variation of radiation reactance with respect to frequency indicates an inductance-like behavior in the same frequency range. We find that the peak radiation resistance value is reached at higher kd values in the collapsed case as compared with the uncollapsed case, where k is the wavenumber and d is the center-to-center distance between two neighboring CMUT cells.

[1]  D. T. Yeh,et al.  Experimental characterization of collapse-mode CMUT operation , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  H. Koymen,et al.  Nonlinear modeling of an immersed transmitting capacitive micromachined ultrasonic transducer for harmonic balance analysis , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  Abdullah Atalar,et al.  Silicon micromachined ultrasonic immersion transducers , 1996 .

[4]  A. Atalar,et al.  Optimization of the gain-bandwidth product of capacitive micromachined ultrasonic transducers , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  B. Khuri-Yakub,et al.  Capacitive micromachined ultrasonic transducers: next-generation arrays for acoustic imaging? , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  O. Oralkan,et al.  Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  C. H. Sherman,et al.  Analysis of Acoustic Interactions in Transducer Arrays , 1966, IEEE Transactions on Sonics and Ultrasonics.

[8]  P.-C. Eccardt,et al.  Linear and nonlinear equivalent circuit modeling of CMUTs , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  B.T. Khuri-Yakub,et al.  A new regime for operating capacitive micromachined ultrasonic transducers , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  Ching-Hsiang Cheng,et al.  Comparison of conventional and collapsed region operation of capacitive micromachined ultrasonic transducers , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[11]  O. Oralkan,et al.  Capacitive micromachined ultrasonic transducer design for high power transmission , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  Mario Kupnik,et al.  Capacitive Micromachined Ultrasonic Transducers for Therapeutic Ultrasound Applications , 2010, IEEE Transactions on Biomedical Engineering.

[13]  L. Foldy Theory of Passive Linear Electroacoustic Transducers with Fixed Velocity Distribution , 1949 .

[14]  I. Ladabaum,et al.  Theory and analysis of electrode size optimization for capacitive microfabricated ultrasonic transducers , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  B.T. Khuri-Yakub,et al.  Analytically calculating membrane displacement and the equivalent circuit model of a circular CMUT cell , 2008, 2008 IEEE Ultrasonics Symposium.

[16]  P. R. Stepanishen Impulse response and radiation impedance of an annular piston , 1974 .

[17]  B. Khuri-Yakub,et al.  Surface micromachined capacitive ultrasonic transducers , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[18]  A. Atalar,et al.  Deep-collapse operation of capacitive micromachined ultrasonic transducers , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[19]  H. Koymen,et al.  Parametric linear modeling of circular cMUT membranes in vacuum , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[20]  R.O. Guldiken,et al.  Dual-electrode CMUT with non-uniform membranes for high electromechanical coupling coefficient and high bandwidth operation , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[21]  B. Khuri-Yakub,et al.  Finite element modeling and experimental characterization of crosstalk in 1-D CMUT arrays , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  B.T. Khuri-Yakub,et al.  Finite-element analysis of capacitive micromachined ultrasonic transducers , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[23]  H. Koymen,et al.  An equivalent circuit model for transmitting capacitive micromachined ultrasonic transducers in collapse mode , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[24]  M. Karaman,et al.  Annular-ring CMUT arrays for forward-looking IVUS: transducer characterization and imaging , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[25]  David T. Porter,et al.  Self‐ and Mutual‐Radiation Impedance and Beam Patterns for Flexural Disks in a Rigid Plane , 1964 .

[26]  Martin Greenspan,et al.  Piston radiator: Some extensions of the theory , 1979 .

[27]  M. Kupnik,et al.  Feasibility of MR-temperature mapping of ultrasonic heating from a CMUT , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[28]  Utkan Demirci,et al.  Medical imaging using capacitive micromachined ultrasonic transducer arrays. , 2002, Ultrasonics.

[29]  A. Atalar,et al.  Radiation impedance of an array of circular capacitive micromachined ultrasonic transducers , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[30]  Amin Nikoozadeh,et al.  Forward-looking volumetric intracardiac imaging using a fully integrated CMUT ring array , 2009, 2009 IEEE International Ultrasonics Symposium.

[31]  O. Oralkan,et al.  Fabrication of Flexible Transducer Arrays With Through-Wafer Electrical Interconnects Based on Trench Refilling With PDMS , 2008, Journal of Microelectromechanical Systems.