Microcomputer-based portable long-term spasticity recording system

A device for long-term monitoring of muscle activity (EMG) with surface electrodes and the method of its application are described. This device is called a microcomputer two-channel EMG monitor. The device can be used for up to 24-h monitoring of EMG activity, followed by data transfer to a host computer, for signal analysis. This device records amplified, rectified, and integrated EMG activity. Shorter recording time allows shorter sampling periods suitable for other EMG analysis. Recording of spontaneous EMG in complete spinal cord injured subjects was the original reason for the design of the long-term monitor. These recordings were used for estimation of spasticity in complete spinal cord patients.<<ETX>>

[1]  W O Fenn,et al.  A DYNAMIC METHOD FOR MEASUREMENT OF MUSCLE TONUS IN MAN. , 1930, The Journal of clinical investigation.

[2]  W. B. Matthews Ratio of maximum H reflex to maximum M response as a measure of spasticity. , 1966, Journal of neurology, neurosurgery, and psychiatry.

[3]  J. Gersten,et al.  An objective method of evaluating muscle tightness; preliminary observations on the effectiveness of various procedures in producing muscle relaxation in the hemiplegic extremity. , 1952, Archives of physical medicine and rehabilitation.

[4]  J Duchêne,et al.  Acquisition and processing of surface EMG signals with a low-cost microprocessor based system. , 1982, Journal of biomechanics.

[5]  T Bajd,et al.  Testing and modelling of spasticity. , 1982, Journal of biomedical engineering.

[6]  T. Bajd,et al.  Pendulum testing of spasticity. , 1984, Journal of biomedical engineering.

[7]  O. Miglietta,et al.  Application of the stretch and Hoffman reflexes to the objective measurement of spasticity. , 1961, Archives of Physical Medicine and Rehabilitation.

[8]  R. Stein,et al.  The relation between the surface electromyogram and muscular force. , 1975, The Journal of physiology.

[9]  Chapman Ae,et al.  Estimations of active-state from E.M.G. recordings of human muscular contraction. , 1979 .

[10]  S. Bouisset,et al.  Quantitative relationship between surface EMG and intramuscular electromyographic activity in voluntary movement. , 1972, American journal of physical medicine.

[11]  Simple method to improve performance of fine-wire electrodes. , 1974 .

[12]  Charles G. Burgar,et al.  An EMG Integrator for Muscle Activity Studies in Ambulatory Subjects , 1983, IEEE Transactions on Biomedical Engineering.

[13]  O Hänninen,et al.  Fully rectified, integrated, band (FRIB-) EMG analysis in quantifying muscle activity. Development of a new field equipment. , 1984, Acta physiologica Scandinavica. Supplementum.