DNA electrochemistry with tethered methylene blue.

Methylene blue (MB'), covalently attached to DNA through a flexible C(12) alkyl linker, provides a sensitive redox reporter in DNA electrochemistry measurements. Tethered, intercalated MB' is reduced through DNA-mediated charge transport; the incorporation of a single base mismatch at position 3, 10, or 14 of a 17-mer causes an attenuation of the signal to 62 ± 3% of the well-matched DNA, irrespective of position in the duplex. The redox signal intensity for MB'-DNA is found to be least 3-fold larger than that of Nile blue (NB)-DNA, indicating that MB' is even more strongly coupled to the π-stack. The signal attenuation due to an intervening mismatch does, however, depend on DNA film density and the backfilling agent used to passivate the surface. These results highlight two mechanisms for reduction of MB' on the DNA-modified electrode: reduction mediated by the DNA base pair stack and direct surface reduction of MB' at the electrode. These two mechanisms are distinguished by their rates of electron transfer that differ by 20-fold. The extent of direct reduction at the surface can be controlled by assembly and buffer conditions.

[1]  Elena E Ferapontova,et al.  "Off-on" electrochemical hairpin-DNA-based genosensor for cancer diagnostics. , 2011, Analytical chemistry.

[2]  R. Lai,et al.  Integration of two different sensing modes in an electrochemical DNA sensor for approximation of target mismatch location , 2011 .

[3]  S O Kelley,et al.  Electron transfer between bases in double helical DNA. , 1999, Science.

[4]  M R Arkin,et al.  Long-range photoinduced electron transfer through a DNA helix. , 1993, Science.

[5]  Andrew J. Bonham,et al.  Reagentless, electrochemical approach for the specific detection of double- and single-stranded DNA binding proteins. , 2009, Analytical chemistry.

[6]  Jacqueline K Barton,et al.  DNA-mediated electrochemistry. , 2008, Bioconjugate chemistry.

[7]  Joseph C Genereux,et al.  DNA-mediated charge transport in redox sensing and signaling. , 2010, Journal of the American Chemical Society.

[8]  E. Laviron General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems , 1979 .

[9]  Elizabeth M. Boon,et al.  Single-base mismatch detection based on charge transduction through DNA. , 1999, Nucleic acids research.

[10]  S O Kelley,et al.  Electrochemistry of methylene blue bound to a DNA-modified electrode. , 1997, Bioconjugate chemistry.

[11]  Silvia Lanteri,et al.  Topics in Current Chemistry, 151, 93-143 (1987) , 1987 .

[12]  Alon A Gorodetsky,et al.  Multiplexed DNA-modified electrodes. , 2010, Journal of the American Chemical Society.

[13]  Jacqueline K. Barton,et al.  Oxidative DNA damage through long-range electron transfer , 1996, Nature.

[14]  Elizabeth M. Boon,et al.  An electrical probe of protein–DNA interactions on DNA-modified surfaces , 2002, Nature Biotechnology.

[15]  Rebecca Y Lai,et al.  A folding-based electrochemical aptasensor for detection of vascular endothelial growth factor in human whole blood. , 2011, Biosensors & bioelectronics.

[16]  J. Barton,et al.  Mechanisms for DNA charge transport. , 2010, Chemical reviews.

[17]  H. Wagenknecht Charge Transfer in DNA: From Mechanism to Application , 2005 .

[18]  Kevin W Plaxco,et al.  Preparation of electrode-immobilized, redox-modified oligonucleotides for electrochemical DNA and aptamer-based sensing , 2007, Nature Protocols.

[19]  J Justin Gooding,et al.  Multipotential electrochemical detection of primer extension reactions on DNA self-assembled monolayers. , 2004, Journal of the American Chemical Society.

[20]  J Justin Gooding,et al.  Enzymatic synthesis of redox-labeled RNA and dual-potential detection at DNA-modified electrodes. , 2004, Angewandte Chemie.

[21]  T. G. Drummond,et al.  Electron transfer rates in DNA films as a function of tether length. , 2004, Journal of the American Chemical Society.

[22]  J. Barton,et al.  Coupling into the base pair stack is necessary for DNA-mediated electrochemistry. , 2007, Bioconjugate chemistry.

[23]  Chunhai Fan,et al.  A target-responsive electrochemical aptamer switch (TREAS) for reagentless detection of nanomolar ATP. , 2007, Journal of the American Chemical Society.

[24]  Elizabeth M. Boon,et al.  Reduction of Ferricyanide by Methylene Blue at a DNA-Modified Rotating-Disk Electrode , 2003 .

[25]  H. Soh,et al.  An electrochemical sensor for single nucleotide polymorphism detection in serum based on a triple-stem DNA probe. , 2009, Journal of the American Chemical Society.

[26]  Kock-Yee Law,et al.  Aggregation of a Surfactant Squaraine in Langmuir-Blodgett Films, Solids, and Solution , 1994 .

[27]  J. Barton,et al.  Charge Transfer through the DNA Base Stack , 1997 .

[28]  J. Barton,et al.  Long-range DNA charge transport. , 2003, The Journal of organic chemistry.

[29]  Kevin W Plaxco,et al.  Comparing the properties of electrochemical-based DNA sensors employing different redox tags. , 2009, Analytical chemistry.

[30]  Christoph Rosenbohm,et al.  Dry Column Vacuum Chromatography , 2004 .

[31]  J. Barton,et al.  PHOTOINDUCED ELECTRON TRANSFER IN ETHIDIUM-MODIFIED DNA DUPLEXES : DEPENDENCE ON DISTANCE AND BASE STACKING , 1997 .

[32]  R. Lai,et al.  Comparison of the stem-loop and linear probe-based electrochemical DNA sensors by alternating current voltammetry and cyclic voltammetry. , 2011, Langmuir : the ACS journal of surfaces and colloids.

[33]  L. Cincotta,et al.  Factors Affecting Virus Photoinactivation by a Series of Phenothiazine Dyes , 1998, Photochemistry and photobiology.

[34]  Ryan J. White,et al.  Effects of probe length, probe geometry, and redox-tag placement on the performance of the electrochemical E-DNA sensor. , 2009, Analytical chemistry.

[35]  A. Anne,et al.  3'-Ferrocene-labeled oligonucleotide chains end-tethered to gold electrode surfaces: novel model systems for exploring flexibility of short DNA using cyclic voltammetry. , 2003, Journal of the American Chemical Society.

[36]  M. Hill,et al.  Intercalative Stacking: A Critical Feature of DNA Charge-Transport Electrochemistry , 2003 .

[37]  Y. Chai,et al.  A reagentless and disposable electronic genosensor: from multiplexed analysis to molecular logic gates. , 2011, Chemical communications.

[38]  Elizabeth M. Boon,et al.  Mutation detection by electrocatalysis at DNA-modified electrodes , 2000, Nature Biotechnology.

[39]  M. Hill,et al.  Long-Range Electron Transfer through DNA Films. , 1999, Angewandte Chemie.

[40]  J. Slinker,et al.  DNA charge transport over 34 nm. , 2011, Nature chemistry.

[41]  A. Wang,et al.  Formaldehyde cross-links daunorubicin and DNA efficiently: HPLC and X-ray diffraction studies. , 1992, Biochemistry.

[42]  R. Lai,et al.  Effect of diluent chain length on the performance of the electrochemical DNA sensor at elevated temperature. , 2011, The Analyst.

[43]  Kevin W Plaxco,et al.  Optimization of a reusable, DNA pseudoknot-based electrochemical sensor for sequence-specific DNA detection in blood serum. , 2009, Analytical chemistry.