Photoneutron production of a Siemens Primus linear accelerator studied by Monte Carlo methods and a paired magnesium and boron coated magnesium ionization chamber system

When radiotherapy with photon energies greater than 10 MV is performed neutrons contaminate the photon beam. In this paper the neutron contamination of the 15 MV photon mode of the Siemens Primus accelerator was studied. The Monte Carlo code MCNPX was used for the description of the treatment head and treatment room. The Monte Carlo results were verified by studying the photon depth dose curve and beam profiles in a water phantom. After these verifications the locations of neutron production were studied and the neutron source spectrum and strength were calculated. The neutron response of the paired Mg/Ar and MgB/Ar ionization chamber system was calculated and experimentally verified for two experimental set-ups. The paired chamber system allowed us to measure neutrons inside the field borders and allowed rapid and point wise measurement in contrast to other methods of neutron detection.

[1]  R. Schmidt,et al.  Set-up and calibration of a triple ionization chamber system for dosimetry in mixed neutron/photon fields , 2007, Physics in medicine and biology.

[2]  J. Pena,et al.  Monte Carlo study of Siemens PRIMUS photoneutron production , 2005, Physics in medicine and biology.

[3]  G. Fullerton,et al.  Investigation of secondary neutron dose for 18 MV dynamic MLC IMRT delivery. , 2005, Medical physics.

[4]  J. Pena,et al.  Commissioning of a medical accelerator photon beam Monte Carlo simulation using wide-field profiles. , 2004, Physics in medicine and biology.

[5]  K W Burn,et al.  Monte Carlo simulation of the photoneutron field in linac radiotherapy treatments with different collimation systems , 2004, Physics in medicine and biology.

[6]  Omar Chibani,et al.  Photonuclear dose calculations for high-energy photon beams from Siemens and Varian linacs. , 2003, Medical physics.

[7]  D. Followill,et al.  Neutron source strength measurements for Varian, Siemens, Elekta, and General Electric linear accelerators , 2003, Journal of applied clinical medical physics.

[8]  T. Chu,et al.  Monte Carlo simulation of surface percent depth dose. , 2002, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[9]  D. Sheikh-Bagheri,et al.  Sensitivity of megavoltage photon beam Monte Carlo simulations to electron beam and other parameters. , 2002, Medical physics.

[10]  T. Chu,et al.  The measurement of photoneutrons in the vicinity of a Siemens Primus linear accelerator. , 2001, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[11]  C. Manfredotti,et al.  Analysis of photoneutron spectra produced in medical accelerators , 2000, Physics in medicine and biology.

[12]  J. Burmeister,et al.  Paired Mg and Mg(B) ionization chambers for the measurement of boron neutron capture dose in neutron beams. , 1999, Medical physics.

[13]  R Nath,et al.  In-phantom dosimetry and spectrometry of photoneutrons from an 18 MV linear accelerator. , 1998, Medical physics.

[14]  R Schmidt,et al.  Determination of the thermal neutron flux in a fast neutron beam by use of a boron-coated ionization chamber. , 1995, Medical physics.

[15]  A. Torresin,et al.  Neutron measurements around medical electron accelerators by active and passive detection techniques. , 1991, Medical physics.

[16]  文献委員会 Neutron contamination of X ray beams produced by the Varian Clinac 1800, Patton H McGinley et al, Physics in Medicine and Biology, 34, (6), 777-783, (1989) , 1990 .

[17]  P H McGinley,et al.  Neutron contamination of X-ray beams produced by the Varian Clinac 1800 , 1989 .