Time-resolved imaging of fluorescent inclusions in optically turbid medium — phantom study

We present results of application of a time-resolved optical system for imaging of fluorescence excited in an inclusion containing indocyanine green (ICG), and located in optically turbid medium. The developed imaging system enabled simultaneous acquisition of fluorescence and diffusive reflectance. Eight independent time-resolved measurement channels based on time-correlated single photon counting technique were applied. In four of these channels, used for the fluorescence detection, sets of filters were applied in order to block the excitation light. Fast optomechanical switches allowed us to illuminate sequentially nine different spots on the surface of the studied object and finally 4×4 pixels maps at excitation and emission wavelengths were obtained. A liquid phantom used in this study consists of the fish tank filed with a solution ofmilk and water with black ink added to obtain optical properties in the range of the optical properties typical for the living tissue. A gel ball of a diameter of 5 mm with precisely controlled concentration of ICG was immersed in the liquid. The measurements were performed for inclusion located at different depths and for various ICG concentrations in the gel ball and in the surrounding liquid. The recorded distributions of times of arrival (DTA) of fluorescence photons and times of flight (DTOF) of diffusely reflected photons were analyzed by calculation of their statistical moments. We observed specific changes in moments of the measured DTAs as a function of depth of immersion of the fluorescent inclusion in the medium. We noted also that the changes of moments depend significantly on concentration of the dye in the fluorescence inclusion as well as in the surrounding liquid.

[1]  J. Slakter,et al.  Adverse Reactions due to Indocyanine Green , 1994 .

[2]  M S Patterson,et al.  A diffusion theory model of spatially resolved fluorescence from depth-dependent fluorophore concentrations. , 2001, Physics in medicine and biology.

[3]  E Gratton,et al.  Experimental verification of a theory for the time-resolved fluorescence spectroscopy of thick tissues. , 1997, Applied optics.

[4]  J. S. Reynolds,et al.  Measurement of the fluorescence lifetime in scattering media by frequency-domain photon migration. , 1999, Applied optics.

[5]  B. Culliton Scientific “experts” and the law , 1997, Nature Medicine.

[6]  S. Ragnarsson Scattering phenomena in volume holograms with strong coupling. , 1978, Applied optics.

[7]  J. S. Reynolds,et al.  Imaging of Spontaneous Canine Mammary Tumors Using Fluorescent Contrast Agents , 1999, Photochemistry and photobiology.

[8]  Michael S Patterson,et al.  The use of spatially resolved fluorescence and reflectance to determine interface depth in layered fluorophore distributions. , 2003, Physics in medicine and biology.

[9]  S Kumar,et al.  Analytical models for time resolved fluorescence spectroscopy in tissues. , 2001, Physics in Medicine and Biology.

[10]  Vasilis Ntziachristos,et al.  Shedding light onto live molecular targets , 2003, Nature Medicine.

[11]  T. Desmettre,et al.  Fluorescence properties and metabolic features of indocyanine green (ICG) as related to angiography. , 2000, Survey of ophthalmology.

[12]  M. Schweiger,et al.  Three-dimensional in vivo fluorescence diffuse optical tomography of breast cancer in humans. , 2007, Optics express.

[13]  Heidrun Wabnitz,et al.  Non-invasive detection of fluorescence from exogenous chromophores in the adult human brain , 2006, NeuroImage.

[14]  H. Sugimoto,et al.  ICG pulse spectrophotometry for perioperative liver function in hepatectomy. , 2002, The Journal of surgical research.

[15]  J. Lakowicz Principles of fluorescence spectroscopy , 1983 .

[16]  K. Awazu,et al.  Clinical applications of ICG Finger Monitor in patients with liver disease. , 1993, Journal of hepatology.

[17]  Yong Wang,et al.  Simple time-domain optical method for estimating the depth and concentration of a fluorescent inclusion in a turbid medium. , 2004, Optics letters.

[18]  R. Weissleder Scaling down imaging: molecular mapping of cancer in mice , 2002, Nature Reviews Cancer.

[19]  Retina: indocyanine green (ICG) angiography. , 1994, Insight.

[20]  R. Maniewski,et al.  Time-resolved optical imager for assessment of cerebral oxygenation. , 2007, Journal of biomedical optics.

[21]  Piotr Sawosz,et al.  Monitoring of contrast agent inflow into human brain by multichannel time-resolved diffuse reflectometry , 2008 .

[22]  R. C. Benson,et al.  Fluorescence properties of indocyanine green as related to angiography. , 1978, Physics in medicine and biology.

[23]  Heidrun Wabnitz,et al.  Evaluation of optical properties of highly scattering media by moments of distributions of times of flight of photons. , 2003, Applied optics.

[24]  J Wu,et al.  Time-resolved multichannel imaging of fluorescent objects embedded in turbid media. , 1995, Optics letters.

[25]  Vasilis Ntziachristos,et al.  Looking and listening to light: the evolution of whole-body photonic imaging , 2005, Nature Biotechnology.

[26]  M S Patterson,et al.  Noninvasive measurement of fluorophore concentration in turbid media with a simple fluorescence /reflectance ratio technique. , 2001, Applied optics.

[27]  Tong San Koh,et al.  A distributed parameter model of cerebral blood-tissue exchange with account of capillary transit time distribution , 2006, NeuroImage.

[28]  C. J. Marek,et al.  Mechanism of action of the antifibrogenic compound gliotoxin in rat liver cells , 2004, Hepatology.

[29]  D Nolte,et al.  Time gated fluorescence spectroscopy in Barrett’s oesophagus , 2003, Gut.

[30]  J. Fishbaugh Lessons on dilation. , 1994, Insight.

[31]  K Svanberg,et al.  Clinical multi-colour fluorescence imaging of malignant tumours - initial experience , 1998, Acta radiologica.

[32]  Heidrun Wabnitz,et al.  Bed-side assessment of cerebral perfusion in stroke patients based on optical monitoring of a dye bolus by time-resolved diffuse reflectance , 2005, NeuroImage.

[33]  A. Villringer,et al.  Time-resolved multidistance near-infrared spectroscopy of the adult head: intracerebral and extracerebral absorption changes from moments of distribution of times of flight of photons. , 2004, Applied optics.

[34]  W. Semmler,et al.  Receptor-targeted optical imaging of tumors with near-infrared fluorescent ligands , 2001, Nature Biotechnology.

[35]  C. L. Hutchinson,et al.  Fluorescence-lifetime determination in tissues or other scattering media from measurement of excitation and emission kinetics. , 1996, Applied optics.

[36]  B W Pogue,et al.  Fiber-optic bundle design for quantitative fluorescence measurement from tissue. , 1998, Applied optics.

[37]  M Loew,et al.  Analytical solutions for time-resolved fluorescence lifetime imaging in a turbid medium such as tissue. , 2001, Journal of the Optical Society of America. A, Optics, image science, and vision.

[38]  Daniel L. Farkas,et al.  Biomedical Optical Imaging , 2009 .

[39]  R Macdonald,et al.  Monte Carlo algorithm for efficient simulation of time-resolved fluorescence in layered turbid media. , 2008, Optics express.

[40]  R. Weissleder,et al.  Fluorescence molecular tomography resolves protease activity in vivo , 2002, Nature Medicine.

[41]  W. Kaiser,et al.  An in vitro characterization study of new near infrared dyes for molecular imaging. , 2009, European journal of medicinal chemistry.

[42]  A. Liebert,et al.  Towards Noninvasive Molecular Fluorescence Imaging of the Human Brain , 2008, Neurodegenerative Diseases.

[43]  Brian Pogue,et al.  Quantitative fluorescence lifetime spectroscopy in turbid media: comparison of theoretical, experimental and computational methods. , 2002, Physics in medicine and biology.

[44]  F Martelli,et al.  Liquid phantom for investigating light propagation through layered diffusive media. , 2004, Optics express.

[45]  Michael S Patterson,et al.  Measurement of fluorophore concentrations and fluorescence quantum yield in tissue-simulating phantoms using three diffusion models of steady-state spatially resolved fluorescence. , 2003, Physics in medicine and biology.

[46]  Brian W. Pogue,et al.  Mathematical model for time-resolved and frequency-domain fluorescence spectroscopy in biological tissues. , 1994, Applied optics.

[47]  M S Patterson,et al.  Imaging of fluorescent yield and lifetime from multiply scattered light reemitted from random media. , 1997, Applied optics.