Pre-emptive arc fault detection techniques in switchgear-part III, from the laboratory to practical installation

Major types of slowly developing faults, which can lead to arc faults in switchgear and control gear, such as partial discharge (PD), arcing and heating due to poor connections, can now be successfully detected and monitored. In part I and II of this paper series, a detailed review of the immediate causes of arc faults, along with an overview of pre-ignition and post-ignition methods for its mitigation were presented. Various hybrid non-intrusive sensors were developed in the laboratory to implement pre-ignition detection techniques. The major types of slowly developing electrical faults were created in the laboratory and the sensors were employed to evaluate their performance along with an effective signal processing technique. Part III of the work is based on the successful performance of the sensors outside of laboratory conditions. Hybrid sensors have been installed in a real world application, i.e. switchgear located in substations. This paper presents interesting results about this practical application, and includes valuable discussion on the performance evaluation of different sensors, which further justifies the usefulness of the new sensors for online condition monitoring of switchgear, controlgear and cable termination boxes. The implementation of this technology in industry may provide promising results in avoiding major accidents such as arc flash in switchgear and controlgear.

[1]  J. A. Kay,et al.  Pre-emptive arc fault detection techniques in switchgear and controlgear , 2012, 2012 Petroleum and Chemical Industry Conference (PCIC).

[2]  D. Brechtken Preventive arc fault protection , 2001, 2001 IEEE/PES Transmission and Distribution Conference and Exposition. Developing New Perspectives (Cat. No.01CH37294).

[3]  J.J. Shea Conditions for Series Arcing Phenomena in PVC Wiring , 2007, IEEE Transactions on Components and Packaging Technologies.

[4]  L. Satish,et al.  Wavelet-based denoising of partial discharge signals buried in excessive noise and interference , 2003 .

[5]  J.D. van Wyk,et al.  An overview of integratable current sensor technologies , 2003, 38th IAS Annual Meeting on Conference Record of the Industry Applications Conference, 2003..

[6]  James R. Andrews UWB Signal Sources , Antennas & Propagation , 2003 .

[7]  Matti Lehtonen,et al.  The Smart Solution for the Prediction of Slowly Developing Electrical Faults in MV Switchgear Using Partial Discharge Measurements , 2013, IEEE Transactions on Power Delivery.

[8]  J. R. Andrews,et al.  UWB signal sources, antennas and propagation , 2003, 2003 IEEE Topical Conference on Wireless Communication Technology.

[9]  G.C. Stone,et al.  Partial discharge diagnostics and electrical equipment insulation condition assessment , 2005, IEEE Transactions on Dielectrics and Electrical Insulation.

[10]  Ralph H. Lee,et al.  Pressures Developed by Arcs , 1987, IEEE Transactions on Industry Applications.

[11]  H.B. Land,et al.  Design of a sensor to predict arcing faults in nuclear switchgear , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.

[12]  M. Muhr,et al.  Unconventional partial discharge measurement [electrical insulation evaluation] , 2004, The 17th Annual Meeting of the IEEE Lasers and Electro-Optics Society, 2004. LEOS 2004..

[13]  S. Okabe,et al.  Cross-equipment Evaluation of Partial Discharge Measurement and Diagnosis Techniques in Electric Power Apparatus for Transmission and Distribution , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[14]  Stefan Tenbohlen,et al.  Characteristics of Series and Parallel Low Current Arc Faults in the Time and Frequency Domain , 2010, 2010 Proceedings of the 56th IEEE Holm Conference on Electrical Contacts.