Pulse Transit Time Based Continuous Cuffless Blood Pressure Estimation: A New Extension and A Comprehensive Evaluation

Cuffless technique enables continuous blood pressure (BP) measurement in an unobtrusive manner, and thus has the potential to revolutionize the conventional cuff-based approaches. This study extends the pulse transit time (PTT) based cuffless BP measurement method by introducing a new indicator – the photoplethysmogram (PPG) intensity ratio (PIR). The performance of the models with PTT and PIR was comprehensively evaluated in comparison with six models that are based on sole PTT. The validation conducted on 33 subjects with and without hypertension, at rest and under various maneuvers with induced BP changes, and over an extended calibration interval, respectively. The results showed that, comparing to the PTT models, the proposed methods achieved better accuracy on each subject group at rest state and over 24 hours calibration interval. Although the BP estimation errors under dynamic maneuvers and over extended calibration interval were significantly increased for all methods, the proposed methods still outperformed the compared methods in the latter situation. These findings suggest that additional BP-related indicator other than PTT has added value for improving the accuracy of cuffless BP measurement. This study also offers insights into future research in cuffless BP measurement for tracking dynamic BP changes and over extended periods of time.

[1]  Yuan-Ting Zhang,et al.  Continuous Cuffless Blood Pressure Estimation Using Pulse Transit Time and Photoplethysmogram Intensity Ratio , 2016, IEEE Transactions on Biomedical Engineering.

[2]  Carmen C. Y. Poon,et al.  Flexible Piezoresistive Sensor Patch Enabling Ultralow Power Cuffless Blood Pressure Measurement , 2016 .

[3]  Takehiro Yamakoshi,et al.  Advanced Volume-Compensation Method for Indirect Finger Arterial Pressure Determination: Comparison with Brachial Sphygmomanometry , 2017, IEEE Transactions on Biomedical Engineering.

[4]  Ko Keun Kim,et al.  Effect of confounding factors on blood pressure estimation using pulse arrival time , 2008, Physiological measurement.

[5]  Zhi-Hong Mao,et al.  Cuff-free blood pressure estimation using pulse transit time and heart rate , 2014, 2014 12th International Conference on Signal Processing (ICSP).

[6]  A. Hill,et al.  The Velocity of the Pulse Wave in Man , 1922 .

[7]  Xiaorong Ding,et al.  Impact of heart disease and calibration interval on accuracy of pulse transit time–based blood pressure estimation , 2016, Physiological measurement.

[8]  Yuan-Ting Zhang,et al.  Photoplethysmogram intensity ratio: A potential indicator for improving the accuracy of PTT-based cuffless blood pressure estimation , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[9]  Gianfranco Parati,et al.  Assessment and management of blood-pressure variability , 2014, Nature Reviews Cardiology.

[10]  Carmen C. Y. Poon,et al.  Cuff-less and Noninvasive Measurements of Arterial Blood Pressure by Pulse Transit Time , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[11]  L. Ferder,et al.  Emerging Role of Nitric Oxide and Heat Shock Proteins in Insulin Resistance , 2015, Current Hypertension Reports.

[12]  Omer T. Inan,et al.  Weighing Scale-Based Pulse Transit Time is a Superior Marker of Blood Pressure than Conventional Pulse Arrival Time , 2016, Scientific Reports.

[13]  Wenli Wu,et al.  [Mobile Health: IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices]. , 2015, Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation.

[14]  A Mathewson,et al.  An examination of calibration intervals required for accurately tracking blood pressure using pulse transit time algorithms , 2013, Journal of Human Hypertension.

[15]  P. Levy,et al.  New Approaches to Evaluating and Monitoring Blood Pressure , 2016, Current Hypertension Reports.

[16]  B. J. Sjöberg,et al.  Cardiac output and blood pressure during active and passive standing. , 1996, Clinical physiology.

[17]  Yuan-Ting Zhang,et al.  Continuous Blood Pressure Measurement From Invasive to Unobtrusive: Celebration of 200th Birth Anniversary of Carl Ludwig , 2016, IEEE J. Biomed. Health Informatics.

[18]  Enric Monte-Moreno,et al.  Non-invasive estimate of blood glucose and blood pressure from a photoplethysmograph by means of machine learning techniques , 2011, Artif. Intell. Medicine.

[19]  Yukihiro Sawada,et al.  Examination of normalized pulse volume-blood volume relationship: toward a more valid estimation of the finger sympathetic tone. , 2003, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[20]  Mamoru Tamura,et al.  Diffusing-wave absorption spectroscopy in homogeneous turbid media , 1996 .

[21]  M. Masè,et al.  Feasibility of cuff-free measurement of systolic and diastolic arterial blood pressure. , 2011, Journal of electrocardiology.

[22]  P. Novak,et al.  Assessment of sympathetic index from the Valsalva maneuver , 2011, Neurology.

[23]  J. Ruiz-Rodríguez,et al.  Innovative continuous non-invasive cuffless blood pressure monitoring based on photoplethysmography technology , 2013, Intensive Care Medicine.

[24]  Survi Kyal,et al.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice , 2015, IEEE Transactions on Biomedical Engineering.

[25]  Daniel W. Jones,et al.  The Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure: the JNC 7 report. , 2003, JAMA.

[26]  Qiao Zhang,et al.  Noninvasive cuffless blood pressure estimation using pulse transit time and Hilbert-Huang transform , 2013, Comput. Electr. Eng..

[27]  C. Douniama,et al.  Blood pressure tracking capabilities of pulse transit times in different arterial segments: A clinical evaluation , 2009, 2009 36th Annual Computers in Cardiology Conference (CinC).

[28]  X. Aubert,et al.  Is pulse transit time a good indicator of blood pressure changes during short physical exercise in a young population? , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[29]  Takehiro Yamakoshi,et al.  Validation of normalized pulse volume in the outer ear as a simple measure of sympathetic activity using warm and cold pressor tests: towards applications in ambulatory monitoring. , 2013, Physiological measurement.

[30]  Hoda Mohammadzade,et al.  Cuff-less high-accuracy calibration-free blood pressure estimation using pulse transit time , 2015, 2015 IEEE International Symposium on Circuits and Systems (ISCAS).

[31]  Yuan-Ting Zhang,et al.  A new modeling methodology for continuous cuffless blood pressure measurement , 2016, 2016 IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI).

[32]  Tamar Frankel [The theory and the practice...]. , 2001, Tijdschrift voor diergeneeskunde.

[33]  T. Togawa,et al.  Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration , 2000, Medical and Biological Engineering and Computing.

[34]  X. Aubert,et al.  Cuffless Estimation of Systolic Blood Pressure for Short Effort Bicycle Tests: The Prominent Role of the Pre-Ejection Period , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[35]  Louis H Weimer,et al.  Autonomic Testing: Common Techniques and Clinical Applications , 2010, The neurologist.