Stability Analysis of Grid-Connected Voltage-Source Converters Using SISO Modeling

The interaction of a grid-connected voltage-source converter with a weak grid is of significant interest. In this paper, the converter together with the grid impedance is modeled as a single-input single-output (SISO) system. Provided that certain assumptions hold, this allows us to apply the standard SISO Nyquist stability criterion for stability analysis and controller design. The derived model is verified against time-domain simulations and experiments. The method facilitates the design of the converter control system with adequate stability margins.

[1]  R. Iravani,et al.  Multivariable Dynamic Model and Robust Control of a Voltage-Source Converter for Power System Applications , 2009, IEEE Transactions on Power Delivery.

[2]  T.C. Green,et al.  Modeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid , 2007, IEEE Transactions on Power Electronics.

[3]  Bo Wen,et al.  Impedance-Based Analysis of Grid-Synchronization Stability for Three-Phase Paralleled Converters , 2014, IEEE Transactions on Power Electronics.

[4]  Lennart Harnefors,et al.  Modeling of Three-Phase Dynamic Systems Using Complex Transfer Functions and Transfer Matrices , 2007, IEEE Transactions on Industrial Electronics.

[5]  Tuomas Messo,et al.  MIMO-Identification Techniques for Rapid Impedance-Based Stability Assessment of Three-Phase Systems in DQ Domain , 2018, IEEE Transactions on Power Electronics.

[6]  Frede Blaabjerg,et al.  Harmonic Stability in Power Electronic-Based Power Systems: Concept, Modeling, and Analysis , 2019, IEEE Transactions on Smart Grid.

[7]  Staffan Norrga,et al.  Ac-side admittance calculation for modular multilevel converters , 2017, 2017 IEEE 3rd International Future Energy Electronics Conference and ECCE Asia (IFEEC 2017 - ECCE Asia).

[8]  Dong Wang,et al.  Modeling of Grid-Connected DFIG-Based Wind Turbines for DC-Link Voltage Stability Analysis , 2015, IEEE Transactions on Sustainable Energy.

[9]  Frede Blaabjerg,et al.  Modeling and Analysis of Harmonic Stability in an AC Power-Electronics-Based Power System , 2014, IEEE Transactions on Power Electronics.

[10]  J. Doyle Robustness of multiloop linear feedback systems , 1978, 1978 IEEE Conference on Decision and Control including the 17th Symposium on Adaptive Processes.

[11]  Lidong Zhang Modeling and Control of VSC-HVDC Links Connected to Weak AC Systems , 2010 .

[12]  Dong Wang,et al.  DC-Bus Voltage Control Stability Affected by AC-Bus Voltage Control in VSCs Connected to Weak AC Grids , 2016, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[13]  Frede Blaabjerg,et al.  Impedance-Based Analysis of DC-Link Voltage Dynamics in Voltage-Source Converters , 2019, IEEE Transactions on Power Electronics.

[14]  Oriol Gomis-Bellmunt,et al.  Methodology for Droop Control Dynamic Analysis of Multiterminal VSC-HVDC Grids for Offshore Wind Farms , 2011 .

[15]  Dushan Boroyevich,et al.  Novel reduced-order small-signal model of a three-phase PWM rectifier and its application in control design and system analysis , 1996 .

[16]  Staffan Norrga,et al.  Dynamic Analysis of Modular Multilevel Converters , 2013, IEEE Transactions on Industrial Electronics.

[17]  Christoph Buchhagen,et al.  BorWin1 - First Experiences with harmonic interactions in converter dominated grids , 2016 .

[18]  Hao Yuan,et al.  Modeling of Grid-Connected VSCs for Power System Small-Signal Stability Analysis in DC-Link Voltage Control Timescale , 2017, IEEE Transactions on Power Systems.

[19]  M. Belkhayat,et al.  Stability criteria for AC power systems with regulated loads , 1997 .

[20]  Jiabing Hu,et al.  Modeling of VSC Connected to Weak Grid for Stability Analysis of DC-Link Voltage Control , 2015, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[21]  Xiongfei Wang,et al.  Harmonic Instability Assessment Using State-Space Modeling and Participation Analysis in Inverter-Fed Power Systems , 2017, IEEE Transactions on Industrial Electronics.

[22]  S.K. Panda,et al.  A Simple Single-Input–Single-Output (SISO) Model for a Three-Phase PWM Rectifier , 2009, IEEE Transactions on Power Electronics.

[23]  H. Akagi,et al.  Control and Experiment of Pulsewidth-Modulated Modular Multilevel Converters , 2009, IEEE Transactions on Power Electronics.

[24]  J.M. Undrill,et al.  Subsynchronous oscillations part 1 ߞ comprehensive system stability analysis , 1976, IEEE Transactions on Power Apparatus and Systems.

[25]  Frede Blaabjerg,et al.  VSC Input-Admittance Modeling and Analysis Above the Nyquist Frequency for Passivity-Based Stability Assessment , 2017, IEEE Transactions on Industrial Electronics.

[26]  Chun Li,et al.  Unstable Operation of Photovoltaic Inverter From Field Experiences , 2018, IEEE Transactions on Power Delivery.

[27]  Xiongfei Wang,et al.  SISO Transfer Functions for Stability Analysis of Grid-Connected Voltage-Source Converters , 2018, IEEE Transactions on Industry Applications.

[28]  Massimo Bongiorno,et al.  Analytical Derivation of the AC-Side Input Admittance of a Modular Multilevel Converter With Open- and Closed-Loop Control Strategies , 2018, IEEE Transactions on Power Delivery.

[29]  Massimo Bongiorno,et al.  Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters , 2007, IEEE Transactions on Industrial Electronics.

[30]  Massimo Bongiorno,et al.  Frequency-domain passivity-based current controller design , 2008 .

[31]  D. Boroyevich,et al.  Small-signal modeling and control of three-phase PWM converters , 1994, Proceedings of 1994 IEEE Industry Applications Society Annual Meeting.

[32]  Frede Blaabjerg,et al.  Unified Impedance Model of Grid-Connected Voltage-Source Converters , 2018, IEEE Transactions on Power Electronics.

[33]  Olav Bjarte Fosso,et al.  Use of participation factors and parameter sensitivities in study and improvement of low-frequency stability between electrical rail vehicle and power supply , 2009, 2009 13th European Conference on Power Electronics and Applications.

[34]  Bo Wen,et al.  Analysis of D-Q Small-Signal Impedance of Grid-Tied Inverters , 2016, IEEE Transactions on Power Electronics.

[35]  Frede Blaabjerg,et al.  Passivity-Based Stability Assessment of Grid-Connected VSCs—An Overview , 2016, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[36]  I. Postlethwaite,et al.  The generalized Nyquist stability criterion and multivariable root loci , 1977 .

[37]  Robert Eriksson,et al.  Optimizing DC Voltage Droop Settings for AC/DC System Interactions , 2014, IEEE Transactions on Power Delivery.

[38]  V. Blasko,et al.  Operation of a phase locked loop system under distorted utility conditions , 1997 .

[39]  Jian Sun,et al.  Impedance-Based Stability Criterion for Grid-Connected Inverters , 2011, IEEE Transactions on Power Electronics.

[40]  Alfred Rufer,et al.  A Multivariable Design Methodology for Voltage Control of a Single-DG-Unit Microgrid , 2013, IEEE Transactions on Industrial Informatics.