Phase I trial: safety and feasibility of intracranial electroencephalography using hybrid subdural electrodes containing macro- and microelectrode arrays.

OBJECT Cerebral cortex electrophysiology is poorly sampled using standard, low spatial resolution clinical intracranial electrodes. Adding microelectrode arrays to the standard clinical macroelectrode arrays increases the spatial resolution and may ultimately improve the clinical utility of intracranial electroencephalography (iEEG). However, the safety of hybrid electrode systems containing standard clinical macroelectrode and microelectrode arrays is not yet known. The authors report on their preliminary experience in 24 patients who underwent implantation of hybrid electrodes. METHODS In this study, 24 consecutive patients underwent long-term iEEG monitoring with implanted hybrid depth and subdural grid and strip electrodes; both clinical macroelectrodes and research microelectrodes were used. The patients included 18 women and 6 men with an average age of 35 +/- 12 years (range 21-65). The mean hospital stay was 11 +/- 4 days (range 5-20), with mean duration of implantation 7.0 +/- 3.2 days (range 3-15). Data from the 198 consecutive craniotomies for standard clinical subdural grid insertion (prior to surgery in the 24 patients described here) were used for comparison to investigate the relative risk of complications. RESULTS Focal seizure identification and subsequent resection was performed in 20 patients. One patient underwent a subsequent operation after neurological deterioration secondary to cerebral swelling and a 5-mm subdural hematoma. There were no infections. The overall complication rate was 4.2% (only 1 patient had a complication), which did not significantly differ from the complication rate previously reported by the authors of 6.6% when standard subdural and depth intracranial electrodes were used. There were no deaths or permanent neurological deficits related to electrode implantation. CONCLUSIONS The authors demonstrate the use of hybrid subdural strip and grid electrodes containing high-density microwire arrays and standard clinical macroelectrodes. Hybrid electrodes provide high spatial resolution electrophysiology of the neocortex that is impossible with standard clinical iEEG. In this initial study in 24 patients, the complication rate is acceptable, and there does not appear to be increased risk associated with the use of hybrid electrodes compared with standard subdural and depth iEEG electrodes. More research is required to show whether hybrid electrode recordings will improve localization of epileptic foci and tracking the generation of neocortical seizures.

[1]  Charles L. Wilson,et al.  High‐frequency Oscillations after Status Epilepticus: Epileptogenesis and Seizure Genesis , 2004, Epilepsia.

[2]  G. Ojemann,et al.  Subdural strip electrodes for localizing epileptogenic foci. , 1984, Journal of neurosurgery.

[3]  Itzhak Fried,et al.  Interictal high‐frequency oscillations (80–500Hz) in the human epileptic brain: Entorhinal cortex , 2002, Annals of neurology.

[4]  U. Ebeling,et al.  Seizure control following surgery in supratentorial cavernous malformations: a retrospective study in 77 patients , 2005, Acta Neurochirurgica.

[5]  B. Litt,et al.  High-frequency oscillations and seizure generation in neocortical epilepsy. , 2004, Brain : a journal of neurology.

[6]  W S Lee,et al.  Complications and results of subdural grid electrode implantation in epilepsy surgery. , 2000, Surgical neurology.

[7]  A. Bragin,et al.  Analysis of Initial Slow Waves (ISWs) at the Seizure Onset in Patients with Drug Resistant Temporal Lobe Epilepsy , 2007, Epilepsia.

[8]  B. Litt,et al.  High-frequency oscillations in human temporal lobe: simultaneous microwire and clinical macroelectrode recordings. , 2008, Brain : a journal of neurology.

[9]  B. Swartz,et al.  The safety and efficacy of chronically implanted subdural electrodes: a prospective study. , 1996, Surgical neurology.

[10]  A. Parrent,et al.  Morbidity Associated With the Use of Intracranial Electrodes for Epilepsy Surgery , 2006, Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques.

[11]  Magnetic resonance imaging in epilepsy. , 1996, Mayo Clinic proceedings.

[12]  Charles L. Wilson,et al.  High‐frequency oscillations recorded in human medial temporal lobe during sleep , 2004, Annals of neurology.

[13]  Charles L. Wilson,et al.  High‐frequency oscillations in human brain , 1999, Hippocampus.

[14]  Kost Elisevich,et al.  Morbidity and infection in combined subdural grid and strip electrode investigation for intractable epilepsy , 1999, Epilepsy Research.

[15]  Charles L. Wilson,et al.  Quantitative analysis of high-frequency oscillations (80-500 Hz) recorded in human epileptic hippocampus and entorhinal cortex. , 2002, Journal of neurophysiology.

[16]  J. Hahn,et al.  Complications of invasive video-EEG monitoring with subdural grid electrodes , 2002, Neurology.

[17]  Brian Litt,et al.  Human and automated detection of high-frequency oscillations in clinical intracranial EEG recordings , 2007, Clinical Neurophysiology.