Effects of Anti-Icing System Operation on Gas Turbine Performance and Monitoring

The effect of operation of compressor bleed anti-icing on the performance of an industrial gas turbine is analysed. The effect of putting this system in operation is first qualitatively discussed, while the changes on various performance parameters are derived by using a computer engine performance model. The main point of the paper is the study of the effect of anti-icing system operation on parameters used for engine condition monitoring. It is shown that operation of the anti-icing system causes an apparent modification of such parameters, which may reduce the diagnostic ability of an on-line monitoring system and produce false alarms. It is shown that by incorporating the effect of anti-icing system operation into a diagnostic engine model, such problems can be avoided and the diagnostic ability of the system is not influenced by anti-icing activation. The analysis presented is substantiated through experimental data from a twin shaft gas turbine operating in the field.Copyright © 2001 by ASME