Validation of acetabular cup wear volume based on direct and two-dimensional measurements: hip simulator analysis

The volumetric wear in retrieved cups can be assessed by mathematical conversion based on linear measurements and by a fluid-displacement method. We used a hip simulator model to produce wear in 22-, 28-, and 32-mm hip implants and then assessed the volumetric wear using a gravimetric wear method. We then compared the findings with those obtained with the linear and fluid-displacement methods. For the linear method, we translated the linear wear to the volumetric wear using the equations developed by Charnley et al., Kabo et al., and Hashimoto et al. The fluid-displacement method showed the strongest correlation with the gravimetric wear method, and it was found to overestimate the volume slightly (by 3%–9%). According to the linear wear conversion, however, the equation by Kabo widely underestimated the volume by 33%–40%. The equation used by Charnley tended to overestimate the volume (by 4%–17%), whereas Hashimoto's equation tended to slightly underestimate the volume (by 2%–12%). The fluid-displacement method demonstrated an average error of 0.34% ± 13.40% when the wear exceeded 400 mm3. The linear wear was thus converted to the volume wear most accurately using Hashimoto's equation, with the average error being −3.8% ± 14.0%. Of the four measurement modalities, the fluid-displacement method showed the most accurate results. We therefore confirmed that the fluid-displacement method is the most accurate way to determine volumetric wear in retrieved cups.

[1]  H. Oonishi,et al.  The effects of polyethylene cup thickness on wear of total hip prostheses , 1998, Journal of materials science. Materials in medicine.

[2]  A Unsworth,et al.  Wear in Retrieved Charnley Acetabular Sockets , 1996, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[3]  I C Clarke,et al.  Charnley wear model for validation of hip simulators' ball diameter versus polytetrafluoroethylene and polyethylene wear , 1997, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[4]  J. Galante,et al.  Dimensional characteristics of uncomplicated autopsy-retrieved acetabular polyethylene liners by ultrasound. , 1998, Journal of biomedical materials research.

[5]  Duncan Dowson,et al.  An evaluation of the penetration of ceramic femoral heads into polyethylene acetabular cups , 1993 .

[6]  R B Bourne,et al.  Measurement of polyethylene wear in metal-backed acetabular cups. II. Clinical application. , 1995, Clinical orthopaedics and related research.

[7]  A Unsworth,et al.  The association between rates of wear in retrieved acetabular components and the radius of the femoral head , 1998, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[8]  C. Engh,et al.  Wear of Polyethylene Cups in Total Hip Arthroplasty. A Study of Specimens Retrieved Post Mortem* , 1996, The Journal of bone and joint surgery. American volume.

[9]  B. Wroblewski,et al.  Measurement of Wear in Retrieved Acetabular Sockets , 1995, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[10]  T D Brown,et al.  Digital Edge-Detection Measurement of Polyethylene Wear after Total Hip Arthroplasty* , 1997, The Journal of bone and joint surgery. American volume.

[11]  W H Harris,et al.  Wear of Polyethylene Acetabular Components in Total Hip Arthroplasty. An Analysis of One Hundred and Twenty-eight Components Retrieved at Autopsy or Revision Operations* , 1997, The Journal of bone and joint surgery. American volume.

[12]  I. Clarke,et al.  Wear of ultra-high molecular weight polyethylene and polytetrafluoroethylene in a hip simulator: A dose-response study of protein concentration , 2000, Acta orthopaedica Scandinavica.

[13]  S. James,et al.  Clinical wear of 63 ultrahigh molecular weight polyethylene acetabular components: effect of starting resin and forming method. , 1999, Journal of biomedical materials research.

[14]  Wroblewski Bm,et al.  Direction and rate of socket wear in Charnley low-friction arthroplasty , 1985 .

[15]  I. Clarke,et al.  Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene: A survey of 8 reports in the literature , 2001, Acta orthopaedica Scandinavica.

[16]  J. Charnley,et al.  Rate of wear in total hip replacement. , 1975, Clinical orthopaedics and related research.

[17]  I. Clarke,et al.  Water and bovine serum lubrication compared in simulator PTFE/CoCr wear model. , 1996, Journal of biomedical materials research.

[18]  T. Bauer,et al.  Polyethylene wear vector in vivo: A three‐dimensional analysis using retrieved acetabular components and radiographs , 1999, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[19]  J. Kabo,et al.  In vivo wear of polyethylene acetabular components. , 1993, The Journal of bone and joint surgery. British volume.

[20]  B. Morrey,et al.  Effect of femoral head size on wear of the polyethylene acetabular component. , 1990, The Journal of bone and joint surgery. American volume.

[21]  B. Derbyshire The estimation of acetabular cup wear volume from two-dimensional measurements: A comprehensive analysis , 1998, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[22]  D. Sochart,et al.  Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty. , 1999, Clinical orthopaedics and related research.

[23]  Duncan Dowson,et al.  Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints , 1985 .

[24]  T. Bauer,et al.  Three-Dimensional Analysis of Multiple Wear Vectors in Retrieved Acetabular Cups* , 1997, The Journal of bone and joint surgery. American volume.

[25]  Observations on the direction of wear in Charnley sockets retrieved at revision. , 1998, The Journal of bone and joint surgery. British volume.

[26]  J. Galante,et al.  Wear in total hip replacement. , 1971, Surgical forum.