The dynamic simulation model and parameter identification method of DFIG type wind generator for power system electro-mechanic simulation

The double-fed inductor generator (DFIG) is one important type of wind generator. Because of high percentage of wind energy, it is necessary to build accurate wind generator model and parameters for power system electro-mechanic simulation. The paper mainly presents the simulation model and parameter identification method of DFIG type wind generators. For power system transient simulation, the characteristic related to low voltage ride-through (LVRT) is most important, and the model related to LVRT is mainly presented. The parameters of the model are divided into three types and use different identification method. The identification method of important parameters is mainly presented. One actual wind generator is used as an example to explain the identification process and testify the validity of the model.