Optimization of 4D vessel‐selective arterial spin labeling angiography using balanced steady‐state free precession and vessel‐encoding

Vessel‐selective dynamic angiograms provide a wealth of useful information about the anatomical and functional status of arteries, including information about collateral flow and blood supply to lesions. Conventional x‐ray techniques are invasive and carry some risks to the patient, so non‐invasive alternatives are desirable. Previously, non‐contrast dynamic MRI angiograms based on arterial spin labeling (ASL) have been demonstrated using both spoiled gradient echo (SPGR) and balanced steady‐state free precession (bSSFP) readout modules, but no direct comparison has been made, and bSSFP optimization over a long readout period has not been fully explored. In this study bSSFP and SPGR are theoretically and experimentally compared for dynamic ASL angiography. Unlike SPGR, bSSFP was found to have a very low ASL signal attenuation rate, even when a relatively large flip angle and short repetition time were used, leading to a threefold improvement in the measured signal‐to‐noise ratio (SNR) efficiency compared with SPGR. For vessel‐selective applications, SNR efficiency can be further improved over single‐artery labeling methods by using a vessel‐encoded pseudo‐continuous ASL (VEPCASL) approach. The combination of a VEPCASL preparation with a time‐resolved bSSFP readout allowed the generation of four‐dimensional (4D; time‐resolved three‐dimensional, 3D) vessel‐selective cerebral angiograms in healthy volunteers with 59 ms temporal resolution. Good quality 4D angiograms were obtained in all subjects, providing comparable structural information to 3D time‐of‐flight images, as well as dynamic information and vessel selectivity, which was shown to be high. A rapid 1.5 min dynamic two‐dimensional version of the sequence yielded similar image features and would be suitable for a busy clinical protocol. Preliminary experiments with bSSFP that included the extracranial vessels showed signal loss in regions of poor magnetic field homogeneity. However, for intracranial vessel‐selective angiography, the proposed bSSFP VEPCASL sequence is highly SNR efficient and could provide useful information in a range of cerebrovascular diseases. © 2016 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.

[1]  Thomas Lindner,et al.  3D time-resolved vessel-selective angiography based on pseudo-continuous arterial spin labeling. , 2015, Magnetic resonance imaging.

[2]  Davide Piccini,et al.  Nonenhanced arterial spin labeled carotid MR angiography using three‐dimensional radial balanced steady‐state free precession imaging , 2015, Journal of magnetic resonance imaging : JMRI.

[3]  Nader Pouratian,et al.  Noncontrast enhanced four‐dimensional dynamic MRA with golden angle radial acquisition and k‐space weighted image contrast (KWIC) reconstruction , 2014, Magnetic resonance in medicine.

[4]  Roland Bammer,et al.  Time‐Resolved Angiography using InfLow Subtraction (TRAILS) , 2014, Magnetic resonance in medicine.

[5]  M. Günther Perfusion Imaging , 2014, Journal of magnetic resonance imaging : JMRI.

[6]  Michael Helle,et al.  Validation of planning‐free vessel‐encoded pseudo‐continuous arterial spin labeling MR imaging as territorial‐ASL strategy by comparison to super‐selective p‐CASL MRI , 2014, Magnetic resonance in medicine.

[7]  Patrick A Turski,et al.  Noncontrast dynamic 3D intracranial MR angiography using pseudo‐continuous arterial spin labeling (PCASL) and accelerated 3D radial acquisition , 2014, Journal of magnetic resonance imaging : JMRI.

[8]  Danny J. J. Wang,et al.  Time‐resolved noncontrast enhanced 4‐D dynamic magnetic resonance angiography using multibolus TrueFISP‐based spin tagging with alternating radiofrequency (TrueSTAR) , 2014, Magnetic resonance in medicine.

[9]  Michael A. Chappell,et al.  A theoretical framework for quantifying blood volume flow rate from dynamic angiographic data and application to vessel-encoded arterial spin labeling MRI☆ , 2013, Medical Image Anal..

[10]  P. Jezzard,et al.  Cerebral blood flow quantification using vessel-encoded arterial spin labeling , 2013, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[11]  Masanobu Nakamura,et al.  Vessel-selective, non-contrast enhanced, time-resolved MR angiography with vessel-selective arterial spin labeling technique (CINEMA–SELECT) in intracranial arteries , 2013, Radiological Physics and Technology.

[12]  Patrick A Turski,et al.  Noncontrast‐enhanced three‐dimensional (3D) intracranial MR angiography using pseudocontinuous arterial spin labeling and accelerated 3D radial acquisition , 2013, Magnetic resonance in medicine.

[13]  E. Wong,et al.  Fluid Mechanics of Mixing in the Vertebrobasilar System: Comparison of Simulation and MRI , 2012 .

[14]  Peter Jezzard,et al.  A kinetic model for vessel‐encoded dynamic angiography with arterial spin labeling , 2012, Magnetic resonance in medicine.

[15]  Mark W. Woolrich,et al.  A fast analysis method for non-invasive imaging of blood flow in individual cerebral arteries using vessel-encoded arterial spin labelling angiography , 2012, Medical Image Anal..

[16]  A J Nederveen,et al.  Robustness and Reproducibility of Flow Territories Defined by Planning-Free Vessel-Encoded Pseudocontinuous Arterial Spin-Labeling , 2012, American Journal of Neuroradiology.

[17]  Peiying Liu,et al.  Calibration and validation of TRUST MRI for the estimation of cerebral blood oxygenation , 2012, Magnetic resonance in medicine.

[18]  Karla L. Miller,et al.  Real-time cardiac synchronization with fixed volume frame rate for reducing physiological instabilities in 3D FMRI , 2011, NeuroImage.

[19]  D. Norris,et al.  Perfusion territory imaging of intracranial branching arteries – optimization of continuous artery‐selective spin labeling (CASSL) , 2011, NMR in biomedicine.

[20]  N. Rofsky,et al.  Time-resolved vessel-selective digital subtraction MR angiography of the cerebral vasculature with arterial spin labeling. , 2010, Radiology.

[21]  Peter Jezzard,et al.  A general framework for the analysis of vessel encoded arterial spin labeling for vascular territory mapping , 2010, Magnetic resonance in medicine.

[22]  Brian A Hargreaves,et al.  Balanced SSFP transient imaging using variable flip angles for a predefined signal profile , 2010, Magnetic resonance in medicine.

[23]  Weiying Dai,et al.  Modified pulsed continuous arterial spin labeling for labeling of a single artery , 2010, Magnetic resonance in medicine.

[24]  D. Norris,et al.  Superselective pseudocontinuous arterial spin labeling , 2010, Magnetic resonance in medicine.

[25]  Matthias Günther,et al.  Vessel‐encoded dynamic magnetic resonance angiography using arterial spin labeling , 2010, Magnetic resonance in medicine.

[26]  Danny J. J. Wang,et al.  Unenhanced dynamic MR angiography: high spatial and temporal resolution by using true FISP-based spin tagging with alternating radiofrequency. , 2010, Radiology.

[27]  Peter Schmitt,et al.  Non‐contrast‐enhanced four‐dimensional (4D) intracranial MR angiography: A feasibility study , 2010, Magnetic resonance in medicine.

[28]  Krishna S Nayak,et al.  Design and use of variable flip angle schedules in transient balanced SSFP subtractive imaging , 2010, Magnetic resonance in medicine.

[29]  E. Wong,et al.  Mapping of vertebral artery perfusion territories using arterial spin labeling MRI , 2008, Journal of magnetic resonance imaging : JMRI.

[30]  Achim Gass,et al.  Assessment of Intracranial Collateral Flow by Using Dynamic Arterial Spin Labeling MRA and Transcranial Color-Coded Duplex Ultrasound , 2008, Stroke.

[31]  Eric C Wong,et al.  Vessel‐encoded arterial spin‐labeling using pseudocontinuous tagging , 2007, Magnetic resonance in medicine.

[32]  D. Donoho,et al.  Sparse MRI: The application of compressed sensing for rapid MR imaging , 2007, Magnetic resonance in medicine.

[33]  David F Kallmes,et al.  Complications of diagnostic cerebral angiography: evaluation of 19,826 consecutive patients. , 2007, Radiology.

[34]  U. Klose,et al.  FAIR‐TrueFISP imaging of cerebral perfusion in areas of high magnetic susceptibility differences at 1.5 and 3 Tesla , 2007, Journal of magnetic resonance imaging : JMRI.

[35]  Xavier Golay,et al.  Non-invasive visualization of collateral blood flow patterns of the circle of Willis by dynamic MR angiography , 2006, Medical Image Anal..

[36]  K. Scheffler,et al.  Flow compensation in balanced SSFP sequences , 2005, Magnetic resonance in medicine.

[37]  U. Klose,et al.  FAIR true‐FISP perfusion imaging of the kidneys , 2004, Magnetic resonance in medicine.

[38]  R. Edelman,et al.  Flow artifacts in steady‐state free precession cine imaging , 2004, Magnetic resonance in medicine.

[39]  K. Scheffler,et al.  Principles and applications of balanced SSFP techniques , 2003, European Radiology.

[40]  Stephen M Smith,et al.  Fast robust automated brain extraction , 2002, Human brain mapping.

[41]  Michael Brady,et al.  Improved Optimization for the Robust and Accurate Linear Registration and Motion Correction of Brain Images , 2002, NeuroImage.

[42]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[43]  Stephen M. Smith,et al.  A global optimisation method for robust affine registration of brain images , 2001, Medical Image Anal..

[44]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[45]  R R Edelman,et al.  Signal targeting with alternating radiofrequency (STAR) sequences: Application to MR angiography , 1994, Magnetic resonance in medicine.

[46]  Donald S. Williams,et al.  Magnetic resonance imaging of perfusion using spin inversion of arterial water , 1992, Proceedings of the National Academy of Sciences of the United States of America.

[47]  D G Nishimura,et al.  Multiple‐readout selective inversion recovery angiography , 1991, Magnetic resonance in medicine.

[48]  J. Pauly,et al.  MR angiography by selective inversion recovery , 1987, Magnetic resonance in medicine.

[49]  M. Gado,et al.  Projection angiograms of blood labeled by adiabatic fast passage , 1986, Magnetic resonance in medicine.

[50]  G. Zaharchuk,et al.  Recommended implementation of arterial spin-labeled perfusion MRI for clinical applications: A consensus of the ISMRM perfusion study group and the European consortium for ASL in dementia. , 2015, Magnetic resonance in medicine.

[51]  P. Jezzard,et al.  Vessel-Encoded Arterial Spin Labeling Angiography , 2010 .

[52]  P. Weale,et al.  Non-contrast-enhanced 4 D intracranial MR angiography : Optimizations using a variable flip angle approach , 2009 .

[53]  Patrick Le Roux,et al.  Simplified model and stabilization of SSFP sequences. , 2003, Journal of magnetic resonance.

[54]  D G Nishimura,et al.  Analysis and Reduction of the Transient Response in SSFP Imaging , 2000 .

[55]  W. Schaper,et al.  Collateral Circulation , 1993, Springer US.