Gradient‐induced voltages on 12‐lead ECGs during high duty‐cycle MRI sequences and a method for their removal considering linear and concomitant gradient terms
暂无分享,去创建一个
Zion Tsz Ho Tse | Wei Wang | Charles L Dumoulin | Jay Ward | Ronald Watkins | Ehud J Schmidt | Raymond Y Kwong | W. Stevenson | C. Dumoulin | R. Kwong | Jay Ward | E. Schmidt | S. H. Zhang | Wei Wang | William G Stevenson | Shelley HuaLei Zhang | Z. T. Tse | Ronald Watkins
[1] J. Felblinger,et al. Suppression of MR gradient artefacts on electrophysiological signals based on an adaptive real-time filter with LMS coefficient updates , 2004, Magnetic Resonance Materials in Physics, Biology and Medicine.
[2] R Bowtell,et al. Analytic calculations of the E‐fields induced by time‐varying magnetic fields generated by cylindrical gradient coils , 2000, Magnetic resonance in medicine.
[3] D. Cohen,et al. Measurements of the magnetic fields produced by the human heart, brain, and lungs , 1975 .
[4] M A Bernstein,et al. Concomitant magnetic‐field‐induced artifacts in axial echo planar imaging , 1998, Magnetic resonance in medicine.
[5] C. Antzelevitch,et al. Cellular basis for the Brugada syndrome and other mechanisms of arrhythmogenesis associated with ST-segment elevation. , 1999, Circulation.
[6] Martin Bencsik,et al. Electric fields induced in the human body by time-varying magnetic field gradients in MRI: numerical calculations and correlation analysis , 2007, Physics in medicine and biology.
[7] Roger Abächerli,et al. Independent component analysis-based artefact reduction: application to the electrocardiogram for improved magnetic resonance imaging triggering , 2009, Physiological measurement.
[8] Olivier Pietquin,et al. Nonlinear Bayesian Filtering for Denoising of Electrocardiograms Acquired in a Magnetic Resonance Environment , 2010, IEEE Transactions on Biomedical Engineering.
[9] C Antzelevitch,et al. Cellular basis for the normal T wave and the electrocardiographic manifestations of the long-QT syndrome. , 1998, Circulation.
[10] Roger Abächerli,et al. Improving automatic analysis of the electrocardiogram acquired during magnetic resonance imaging using magnetic field gradient artefact suppression. , 2006, Journal of electrocardiology.
[11] Gari D Clifford,et al. A 1.5T MRI‐conditional 12‐lead electrocardiogram for MRI and intra‐MR intervention , 2014, Magnetic resonance in medicine.
[12] N J Pelc,et al. Concomitant gradient terms in phase contrast MR: Analysis and correction , 1998, Magnetic resonance in medicine.
[13] B N Cuffin,et al. Magnetic fields produced by steady currents in the body. , 1980, Proceedings of the National Academy of Sciences of the United States of America.
[14] Roger Abächerli,et al. Noise Cancellation Signal Processing Method and Computer System for Improved Real-Time Electrocardiogram Artifact Correction During MRI Data Acquisition , 2007, IEEE Transactions on Biomedical Engineering.
[15] Giacomo Poggi,et al. Time measurements by means of digital sampling techniques: a study case of 100 ps FWHM time resolution with a 100 MSample/s, 12 bit digitizer , 2004 .
[16] C Antzelevitch,et al. Cellular basis for the electrocardiographic J wave. , 1996, Circulation.
[17] M. Stenroos,et al. Investigations of sensitivity and resolution of ECG and MCG in a realistically shaped thorax model , 2014, Physics in medicine and biology.
[18] Ehud J Schmidt,et al. 3DQRS: A method to obtain reliable QRS complex detection within high field MRI using 12‐lead electrocardiogram traces , 2014, Magnetic resonance in medicine.
[19] Kanishka Ratnayaka,et al. Adaptive noise cancellation to suppress electrocardiography artifacts during real‐time interventional MRI , 2011, Journal of magnetic resonance imaging : JMRI.
[20] R Bowtell,et al. Measurement of electric fields due to time-varying magnetic field gradients using dipole probes , 2007, Physics in medicine and biology.
[21] C. Antzelevitch,et al. Characteristics and distribution of M cells in arterially perfused canine left ventricular wedge preparations. , 1998, Circulation.
[22] D. Porter,et al. Concomitant field terms for asymmetric gradient coils: Consequences for diffusion, flow, and echo‐planar imaging , 2008, Magnetic resonance in medicine.
[23] Y. Rudy,et al. Ionic Current Basis of Electrocardiographic Waveforms: A Model Study , 2002, Circulation research.