Body-on-a chip: Using microfluidic systems to predict human responses to drugs

Using an in vitro platform technology that combines microfabricated devices with cell culture, we seek to understand the response of the human body to pharmaceuticals and combinations of pharmaceuticals. Computer models of the human body guide the design of in vitro systems we call micro cell culture analogs (μCCAs) or “body-on-a-chip” devices. A μCCA device is a physical representation of a physiologically based pharmacokinetic (PBPK) model and contains mammalian cells cultured in interconnected microchambers to represent key organs linked through a circulatory system. μCCAs can provide inexpensive means for realistic, accurate, and rapid-throughput toxicological studies that do not require experimenting with animals and reveal toxic effects that can result from interactions between organs. As the natural length scale in biological systems is on the order of 10–100 μm, operating on the microscale allows us to mimic physiological relationships more accurately. We summarize proof-of-concept experiments using mixtures of drugs to treat multidrug-resistant (MDR) cancer and colon cancer. We discuss the extension of the μCCA concept to systems that connect barrier tissues with systemic circulation. Examples with models of the gastro-intestinal (GI) tract are provided.

[1]  Jong Hwan Sung,et al.  Prevention of air bubble formation in a microfluidic perfusion cell culture system using a microscale bubble trap , 2009, Biomedical microdevices.

[2]  G L Amidon,et al.  Caco-2 versus Caco-2/HT29-MTX co-cultured cell lines: permeabilities via diffusion, inside- and outside-directed carrier-mediated transport. , 2000, Journal of pharmaceutical sciences.

[3]  Miqin Zhang,et al.  Cellular impedance biosensors for drug screening and toxin detection. , 2007, The Analyst.

[4]  P. Artursson,et al.  Co-cultures of human intestinal goblet (HT29-H) and absorptive (Caco-2) cells for studies of drug and peptide absorption , 1995 .

[5]  J. Hickman,et al.  Microelectrode array recordings of cardiac action potentials as a high throughput method to evaluate pesticide toxicity. , 2006, Toxicology in vitro : an international journal published in association with BIBRA.

[6]  Uri Dinnar,et al.  A parametric study of human fibroblasts culture in a microchannel bioreactor. , 2007, Lab on a chip.

[7]  I. Kola,et al.  Can the pharmaceutical industry reduce attrition rates? , 2004, Nature Reviews Drug Discovery.

[8]  M. Shuler,et al.  Development of a stable dual cell‐line GFP expression system to study estrogenic endocrine disruptors , 2008, Biotechnology and bioengineering.

[9]  Masaki Nishikawa,et al.  Feasibility of a simple double-layered coculture system incorporating metabolic processes of the intestine and liver tissue: application to the analysis of benzo[a]pyrene toxicity. , 2004, Toxicology in vitro : an international journal published in association with BIBRA.

[10]  Gilberto Luis Camanho,et al.  Newsweek , 2015, Revista brasileira de ortopedia.

[11]  Donghyun Kim,et al.  Portable in situ fluorescence cytometry of microscale cell-based assays. , 2005, Optics letters.

[12]  M. Conrad,et al.  Regulation of iron absorption: proteins involved in duodenal mucosal uptake and transport. , 1993, Journal of the American College of Nutrition.

[13]  M. Shuler,et al.  In vitro microscale systems for systematic drug toxicity study , 2010, Bioprocess and biosystems engineering.

[14]  Donghyun Kim,et al.  Fluorescence optical detection in situ for real‐time monitoring of cytochrome P450 enzymatic activity of liver cells in multiple microfluidic devices , 2009, Biotechnology and bioengineering.

[15]  M. Yarmush,et al.  Evaluation of a microfluidic based cell culture platform with primary human hepatocytes for the prediction of hepatic clearance in human. , 2009, Biochemical pharmacology.

[16]  Li Xie,et al.  Microelectronic cell sensor assay for detection of cytotoxicity and prediction of acute toxicity. , 2006, Toxicology in vitro : an international journal published in association with BIBRA.

[17]  M L Shuler,et al.  Combining Cell Culture Analogue Reactor Designs and PBPK Models to Probe Mechanisms of Naphthalene Toxicity , 2000, Biotechnology progress.

[18]  Elisabeth Verpoorte,et al.  Microfluidic biochip for the perifusion of precision‐cut rat liver slices for metabolism and toxicology studies , 2010, Biotechnology and bioengineering.

[19]  Aaron Sin,et al.  Development of a Microscale Cell Culture Analog To Probe Naphthalene Toxicity , 2008, Biotechnology progress.

[20]  H. Jaeschke,et al.  Mode of cell death after acetaminophen overdose in mice: apoptosis or oncotic necrosis? , 2002, Toxicological sciences : an official journal of the Society of Toxicology.

[21]  Jen-shih Lee,et al.  1998 Distinguished Lecture: Biomechanics of the Microcirculation, An Integrative and Therapeutic Perspective , 2004, Annals of Biomedical Engineering.

[22]  L M Sweeney,et al.  A cell culture analogue of rodent physiology: Application to naphthalene toxicology. , 1995, Toxicology in vitro : an international journal published in association with BIBRA.

[23]  Elazer R. Edelman,et al.  Adv. Drug Delivery Rev. , 1997 .

[24]  R. Yetter,et al.  A novel electrolytic ignition monopropellant microthruster based on low temperature co-fired ceramic tape technology. , 2009, Lab on a chip.

[25]  Yasuyuki Sakai,et al.  Enhanced cytochrome P450 capacities of Caco-2 and Hep G2 cells in new coculture system under the static and perfused conditions : evidence for possible organ-to-organ interactions against exogenous stimuli , 2004 .

[26]  Mandy B. Esch,et al.  Characterization of a gastrointestinal tract microscale cell culture analog used to predict drug toxicity , 2009, Biotechnology and bioengineering.

[27]  Gretchen J. Mahler,et al.  Characterization of Caco-2 and HT29-MTX cocultures in an in vitro digestion/cell culture model used to predict iron bioavailability. , 2009, The Journal of nutritional biochemistry.

[28]  R. P. Thompson,et al.  Mechanisms of gastrointestinal absorption: dietary minerals and the influence of beverage ingestion , 1994 .

[29]  R K Jain,et al.  Physiologically based pharmacokinetic modeling: principles and applications. , 1983, Journal of pharmaceutical sciences.

[30]  Michael L Shuler,et al.  Incorporation of 3T3‐L1 Cells To Mimic Bioaccumulation in a Microscale Cell Culture Analog Device for Toxicity Studies , 2008, Biotechnology progress.

[31]  K. Anseth,et al.  Hydrogel Cell Cultures , 2007, Science.

[32]  Bethan Hughes,et al.  2008 FDA drug approvals , 2009, Nature Reviews Drug Discovery.

[33]  Jong Hwan Sung,et al.  A micro cell culture analog (microCCA) with 3-D hydrogel culture of multiple cell lines to assess metabolism-dependent cytotoxicity of anti-cancer drugs. , 2009, Lab on a chip.

[34]  W. Charman,et al.  The Mucosa of the Small Intestine , 2002, Clinical pharmacokinetics.

[35]  P. Sperryn,et al.  Blood. , 1989, British journal of sports medicine.

[36]  Yordan Kostov,et al.  The Design and Fabrication of Three‐Chamber Microscale Cell Culture Analog Devices with Integrated Dissolved Oxygen Sensors , 2008, Biotechnology progress.

[37]  Monica Nordberg,et al.  Pharmacology , 1941, The Indian Medical Gazette.

[38]  G. Amidon,et al.  HT29-MTX/Caco-2 cocultures as an in vitro model for the intestinal epithelium: in vitro-in vivo correlation with permeability data from rats and humans. , 1996, Journal of pharmaceutical sciences.

[39]  K. Luthman,et al.  Caco-2 monolayers in experimental and theoretical predictions of drug transport , 1996 .

[40]  C. Larabell,et al.  Reversion of the Malignant Phenotype of Human Breast Cells in Three-Dimensional Culture and In Vivo by Integrin Blocking Antibodies , 1997, The Journal of cell biology.

[41]  Michael L Shuler,et al.  A novel system for evaluation of drug mixtures for potential efficacy in treating multidrug resistant cancers , 2009, Biotechnology and bioengineering.

[42]  Jong Hwan Sung,et al.  A microfluidic device for a pharmacokinetic-pharmacodynamic (PK-PD) model on a chip. , 2010, Lab on a chip.

[43]  Y. Cetin,et al.  A Novel System to Study the Impact of Epithelial Barriers on Cellular Metabolism , 2004, Annals of Biomedical Engineering.